Integral orifice meter run assembly

The integral orifice meter run assembly is a differential pressure flowmeter especially designed for smaller line sizes where the surface roughness, weld seams and other geometrical imperfections have a relatively big influence on the measurement uncertainty. The DP flowmeter therefore features a minimum length of upstream and downstream pipe, reducing additional uncertainties of the installation to a minimum. It is suitable for process and allocation measurement of gases and liquids including viscous fluids, fluids with suspended solids or fluids with gas entrainment. KROHNE offers the complete orifice assembly with orifice meter run, DP transmitter, valves, accessories, engineering, and documentation. The DP flowmeter comes pressure tested and ready for commissioning.

The meter run is available in various designs and compliant with the requirements of the ISO 5167 in terms of pressure tap orientation and dimensions. It is fully machined and straightened to meet the highest dimensional expectations. If required, an additional calibration can be carried out in line with the final operating conditions. KROHNE also supplies special constructions such as redundant taps, integrated flow conditioner, certain paint specifications or advanced NDTs from one source and in accordance with relevant standards (ISO 5167, etc.).

The sophisticated OPTIBAR DP 7060 and OPTIBAR DP 3050 DP transmitters are the perfect companion for this DP flowmeter solution. They are 3D linearised and ensure advanced performance even at high static pressures. The OPTIBAR DP series has an outstanding long-term stability and a low total cost of ownership with a reduced need for field calibrations.

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIBAR
Product positioning For process applications with small line sizes (down to DN15 / ¾″4)
Measurement principle Differential pressure
Measured media Liquids, Gases, Steam
Nominal diameter / size DN20…DN50 / ¾” ..2”

Operating conditions

Process pressure max. 160 bar/
2320 psi
Process temperature -130…+400°C/
-202…+752°F

Materials

Measuring tube Austenitic stainless steel (1.4404/316L), Carbon steel (A105), Alloy steel (ASTM A182 Gr. F12), Alloy steel (ASTM A182 Gr. F22), Alloy steel (ASTM A182 Gr. F91)

Process connections

Flange connections EN (1092-1): DN15…100
ASME (B 16.5): ½…2″

Approvals/Standards

Certificates/Approvals Custody transfer (CT) AGA 3
Certificates/Approvals Ex ATEX, IECEx, NEPSI
Certificates/Approvals Others Oxygen, Pressure Equipment Directive (PED), ISO/TR 11583
Certificates/Approvals Safety SIL 2/3
NAMUR compliance NE 107, NE 21, NE 43, NE 53
Design standards ISO 5167, ASME MFC-3M

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA, Bluetooth

Accuracy

Reference uncertainty 0.15…0.22%
Calibration Volumetric calibration with hot water, Gravimetric calibration with hot water, High pressure natural gas calibration
Spread the love

Contact Us

    Please prove you are human by selecting the heart.