Measuring principle
Differential pressure
-
Characteristic
Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
-
Supply voltage
4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC -
Reference Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–25…+150°C
(–13…+302°F) -
Ambient temperature
–40…+80°C
(–40…+176°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi) -
Vacuum resistance
0 mbar
-
Max. Turn down
100 : 1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Threads
Flansch (DIN, ASME, JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
Ceramic
316L, AlloyC -
Material gasket
Viton, Kalrez, EPDM, NBR, Silicone
-
Fill fluid
Silicone Oil
-
Material housing
Die-cast aluminum
Stainless steel -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG,
3A
-
Measuring principle
Differential pressure
-
Characteristic / Application
Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
-
Supply / Communication
4…20 mA HART:
12…45V DC
Exia: 12…30V DC -
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Ambient temperature
–40…+80°C
(–40…+176°F) -
Process temperature
–25…+150°C
(–13…+302°F) -
Process pressure / max. overpressure limit