Guided radar measurement Time-of-Flight Levelflex FMP51

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device
    Rod probe, Rope probe, Coaxial probe
    Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.

  • Interface measurement

    Clean interfaces liquid/ liquid;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe :+/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
    Coaxial probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -50…+80 °C
    (-58…+176 °F)

  • Process temperature

    -50…+200 °C
    (-58…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    Rod probe:
    316L, Alloy C, Ceramic
    Rope probe:
    316, 316L, Alloy C, Ceramic
    Coaxial probe:
    316L, Alloy C, Ceramic, PFA

  • Process connection

    Thread:
    G3/4…G1 1/2;
    MNPT 3/4…MNPT1 1/2
    Flange:
    ASME 1 1/2″…8″,
    DN50…DN 200,
    JIS 10K

  • Sensor length

    Rod probe: 10 m (33 ft)
    Rope probe: 45 m (148 ft)
    Coaxial probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 10 m (33 ft) Min DK>1.6
    Rope: 25 m…30 m (82ft…98 ft) Min DK>1.6;
    30m…45 m (98ft…148 ft) Min DK>1,9
    Coaxial probe: 6 m (20 ft) Min DK>1.4

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.1, B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Gas-tight feed through,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP51 for level measurement even under extreme process conditions like high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod, rope or coax probe.

Process connections: Threads or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Spread the love