Guided radar measurement Time-of-Flight Levelflex FMP53

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device. Hygiene
    Rod probe,
    ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe:+/- 2 mm (0.08 in)

  • Ambient temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process temperature

    -20…+150 °C
    (-4…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar
    (Vacuum…232 psi)

  • Main wetted parts

    Rod probe:
    304, 304L, 316L, PEEK

  • Process connection

    Thread:
    M24

  • Process connection hygienic

    Tri-Clamp
    DIN11851
    DIN11864-1
    NEUMO
    Varivent N
    SMS

  • Sensor length

    Rod probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 6 m (20 ft)
    Min DK>1.6

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG
    CoC ASME-BPE

  • Options

    Sensor remote with 3 m/9 ft or 6 m/18 ft cable,
    Weld-in adpater,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.

Version with rod probe.

Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO, Varivent N, SMS)
Temperature: -20 to +150°C (-4 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 6m (20ft)
Accuracy: ±2mm (0.12″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Spread the love