Liquiphant FTL63 – hygienic point level switch for liquids

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Premium device for point level detection
    in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
    Modular housing concept.
    Wide range of certificates.

  • Specialities

    Plug and play functionalities,
    Heartbeat Technology,
    LED Module,
    Bluetooth® Operation and maintenance,
    Surface finish: mechanical or electro-polished,
    Density/Concentration measurement,
    SIL 2/3 according to IEC 61508.

  • Supply / Communication

    19 ..253V AC,
    10…55V DC-PNP,
    9…20V DC with relay DPDT,
    19…253V AC or 19…55V DC with relay DPDT,
    8/16mA HART,
    NAMUR,
    PFM

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °F…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…64 bar
    (Vacuum…928 psi)

  • Min. density of medium

    0.5 g/cm³
    (0.4 g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads (for weld-in adapter):
    G3/4A, G1A

  • Process connection hygienic

    Tri-Clamp,
    DIN 11851, DIN11864-1
    Ingold,
    Flush mount,
    DRD,
    SMS1145,
    Varivent (Var )

  • Sensor length

    Compact sensor
    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118″)

  • Communication

    HART
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US, JPN Ex, KC Ex,
    INMETRO Ex, NEPSI Ex/CCC, UK Ex

  • Safety approvals

    Overfill protection WHG;
    SIL 2/ SIL 3

  • Design approvals

    Inspection certificate 3.1, EN10204,
    CoC ASME BPE,
    Conformity to cGMP,
    EU Food Contact Material (EC) 1935/2004,
    US Food Contact Material FDA CFR 21,
    CN Food Contact Material GB 4806,
    Declaration of Conformity ASME B31.3,
    AD2000,
    CRN approval

  • Hygienic approvals

    3-A,
    EHEDG,
    CoC-ASME BPE

  • Options

    LED module,
    Bluetooth module,
    Graphic touch display,
    Customized settings,
    Weld-in adapter

  • Components

    FTL325P Interface PFM
    FTL325N Interface NAMUR
    FML621 Density controller

  • Measuring principle

    Vibration Density

  • Product Headline

    Hygienic point level switch for liquids.
    Point level detection in process and storage tanks as well as in pipelines in hygienic and aseptic applications.

  • Characteristic / Application

    Premium device for density measurement in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Compact sensor version with an optional pipe extension up to 3 m (9,85 ft).
    Modular housing concept.
    Wide range of certificates.

  • Supply / Communication

    via density controller FML621