Absolute and gauge pressure Cerabar PMC71

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Digital transmitter with capacitive sensor and ceramic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply voltage

    4…20 mA HART
    10,5…45V DC (Non Ex):
    Ex ia: 10,5…30V DC
    PROFIBUS PA:
    9…32 V DC (Non Ex)
    FOUNDATION Fieldbus:
    9…32 V DC (Non Ex)

  • Reference Accuracy

    Standard: 0.05%
    Platinum: up to 0.025%

  • Long term stability

    0.05 % of URL/ year
    0.08 % of URL/ 5 years
    0.1 % of URL/ 10 years

  • Process temperature

    -20°C…150°C
    (-4°F…257°F)

  • Ambient temperature

    -40°C…85°C
    (-40°F…185°F)

  • Measuring cell

    100 mbar…40 bar
    (1.5 psi…600 psi)
    relative/ absolute

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. Turn down

    100:1

  • Max. overpressure limit

    60 bar (900 psi)

  • Process connection

    Thread:
    G1/2…G2, R1/2, MNPT1/2…MNPT2
    Flange:
    DN25…DN80,
    ASME 1″…4″,
    JIS 10K

  • Process connection hygienic

    Tri-Clamp
    DIN11851
    Varivent N
    SMS
    DRD

  • Material process membrane

    Ceramic

  • Material gasket

    Viton, EPDM, Chemraz, Kalrez, NBR

  • Fill fluid

    none, dry measuring cell

  • Material housing

    Die-cast aluminum,
    AISI 316L

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex

  • Design approvals

    EN10204-3.1

  • Hygienic approvals

    3A, EHEDG

  • Marine approvals

    GL/ ABS

Spread the love

Contact Us

    Please prove you are human by selecting the house.