Absolute and gauge pressure Cerabar PMP71

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Digital transmitter with piezoresistive sensor and welded metallic membrane
    Modular transmitter
    Long term stability
    Enhanced safety via self diagnostic functionsSecondary process barrier

  • Supply voltage

    4…20 mA HART
    10,5…45V DC (Non Ex):
    Ex ia: 10,5…30V DC
    PROFIBUS PA:
    9…32 V DC (Non Ex)
    FOUNDATION Fieldbus:
    9…32 V DC (Non Ex)

  • Reference Accuracy

    Standard: 0.05%
    Platinum: up to 0.025%

  • Long term stability

    0.05 % of URL/ year
    0.07 % of URL/ 5 years
    0.1 % of URL/ 10 years

  • Process temperature

    -40°C…125°C
    (-40°F…257°F)

  • Ambient temperature

    -50°C…85°C
    (-58°F…185°F)

  • Measuring cell

    400 mbar…700 bar
    (5.8 psi…10.500 psi)
    relative/ absolute

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    10 mbar (0.15 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    1050 bar (15.750 psi)

  • Process connection

    Thread:
    G1/2…G2, R1/2, MNPT1/2…MNPT2, R1/2
    Flange:
    DN25…DN80,
    ASME 1″…4″,
    JIS 10K…20K

  • Material process membrane

    316L, AlloyC,
    Rhodium> Gold

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Silicone oil,
    Inert oil

  • Material housing

    Die-cast aluminum,
    AISI 316L

  • Communication

    4…20 mA HART
    1- 5V DC Low Power
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex