iTEMP TMT162 Temperature field transmitter

  • Measuring principle

    Field transmitter

  • Input

    2 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4…20 mA / HART
    FOUNDATION Fieldbus H1
    PROFIBUS PA

  • Auxiliary power supply

    11,5…42 V DC (HART)
    11,5…30 V DC (Ex ia)
    9…32 V DC (FF, PA)
    10,5…24 V DC (Ex ia, FF, PA)

  • Communication

    HART
    FOUNDATION Fieldbus
    PROFIBUS PA

  • Installation

    in field

  • Accuracy

    (Pt100) <= 0,1 K (HART, FF, PA)
    (Pt100) <= 0,18 °F (HART, FF, PA)

  • Galvanic isolation

    yes

  • Certification

    UL rec. Comp (HART)
    FM IS, NI I/1+2/ABCD
    CSA IS, NI I/1+2/ABCD
    ATEX II1G Ex ia IIC T6
    ATEX II2G Ex d IIC T6
    ATEX II3G Ex nA IIC T6 Gc
    ATEX II3G Ex ic IIC T6 Gc
    ATEX IECEx II2D Ex tb IIIC Db
    ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC
    ATEX Ex d, Ex ia
    FM XP, NI, DIP I,II,III/1+2/A-G
    CSA XP, NI, DIP I,II,III/1+2/A-G
    FM XP, DIP, IS, NI I,II,III/1+2/A-G
    CSA XP, DIP, IS, NI I,II,III/1+2/A-G
    FM+CSA XP,DIP, IS, NI I,II,III/1+2/A-G
    CSA General Purpose
    IECEx Ex ia IIC T6 Ga
    IECEx Ex ia IIC T6 Ga, Ex ia IIIC Db
    IECEx Ex d IIC T6 Gb
    IECEx Ex ia, Ex d
    NEPSI Ex ia IIC T4-T6
    NEPSI Ex nA II T4-T6
    NEPSI Ex d IIC T4-T6
    marine approval only for HART-protocol
    SIL2/3 only for HART-protocol
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    UK II3G Ex nA T6 IIC Gc
    INMETRO Ex db IIC T6 Gb, Ex tb IIIC Db
    INMETRO Ex ia IIC T6 Ga

Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.

Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX350/370, field communicator 475 or remotely via PC FOUNDATION Fieldbus™ ITK 6.1.2PROFIBUS® PA Profile 3.02 Optional: stainless steel housing for hygienic or Ex d application

Benefits
High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronicsBacklit display with large measured value, bar graph and status condition indicationDiagnostics information according to NAMUR NE107International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approvalSIL certification as per IEC 61508:2010Galvanic isolation 2 kV (sensor input / current output)

Spread the love

Contact Us

    Please prove you are human by selecting the cup.