-
Measuring principle
Head transmitter
-
Input
1 x RTD, TC, Ohm, mV
-
Output
1 x analog 4…20 mA / HART
-
Auxiliary power supply
10…36 V DC (Head transmitter)
11…36 V DC (DIN rail device)
10/11…30 V DC (Ex ia) -
Communication
HART-protocol
Bluetooth® wireless technology -
Installation
Terminal head form B / DIN rail / field mount housing
-
Accuracy
(Pt100, -50…200 °C) <= 0,1 K
(Pt100, -58…392 °F) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ic IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II3G Ex nA IIC T6 Gc
ATEX II2G Ex ia IIC T6 Gb, II3D
ATEX II3G Ex nA IIC T6 Gc, II3D
ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
CSA C/US General Purpose
CSA C/US IS, Ex ec I/1+2/A-D
CSA C/US XP, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex nA IIC T6 Gc
IECEx Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex ia IIC T6 Ga
INMETRO Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex nA IIC T6 Gc
NEPSI Ex ia IIC T6 Ga
NEPSI Ex d IIC T6 Gb
NEPSI Ex nA II T6 Gc
UK II1G Ex ia IIC T6 Ga
UK II3D Ex tc IIIC Dc
UK II2G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
ATEX IECEx II1G Ex ia IIC T6 Ga
ATEX IECEx II2D Ex tb IIIC Db
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth® interface for remote operation via Endress+Hauser SmartBlue App.
Bluetooth®-enabled temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signalImproved process efficiency and increased plant uptimeUniversal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)Installation in terminal head form B (flat face) as per DIN EN 50446Installation in cabinets with DIN rail housingOptional installation in field housing even for use in Ex d applications
Benefits
Safe operation in hazardous areas thanks to international approvals Reliable operation thanks to sensor and device monitoring Integrated Bluetooth® interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional Diagnostics information according to NAMUR NE 107 Available with plug-on display TID10Optimization of the measurement accuracy by sensor-transmitter matching.