Measuring principle
Vibration Liquids
-
Characteristic / Application
Modular housing concept
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g. Ex,WHG)
compact, e.g. pipes -
Specialities
Foamdetection
Detekt a densitychange
second line of defense -
Supply / Communication
PROFIBUS PA
19…253V AC
10…55V DC-PNP
19…253V AC or 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM -
Ambient temperature
-50 °C…+70 °C
(-58 °F…+158 °F) -
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F) -
Process pressure / max. overpressure limit
Vacuum…64 bar
(Vacuum…928 psi) -
Min. density of medium
0.5g/cm³(0.4g/cm³ option)
-
Main wetted parts
316L, Alloy
-
Process connection
Thread:
G3/4A, G1A, R3/4″, R1, NPT3/4, NPT1
Flange:
DN25…DN100,
ASME 1″…4″,
JIS 25A…100A -
Process connection hygienic
Tri-Clamp ISO2852
-
Communication
PROFIBUS PA
19…253V AC
10…55V DC-PNP
19…253V AC or 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
-
Safety approvals
SIL2/ SIL3
-
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.3
AD2000 -
Marine approval
GL/ ABS/ DNV
-
Options
Heavy duty stainless steel housing mainly for the oil and gas industry
-
Components
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR -
Successor
Liquiphant FTL51B
-
Measuring principle
Vibration Density
-
Characteristic / Application
Liquiphant M Density
with Density Computer FML621
Temperature and pressure measurement
Modular housing concept
Wide range of process connections -
Supply / Communication
Transmitter power supply (MUS)
-