RIA452 Process indicator with pump control

  • Measuring principle

    Indicators with control unit

  • Measuring principle

    Process indicator with pump control

  • Function

    Display
    Power
    Switch
    Seperate
    Convert
    Count
    Calculate

  • Display

    LCD multicolour
    Illuminated
    Bargraph

  • Power Supply

    90…250 V AC
    20…28 V AC
    20…36 V DC

  • Input

    1 x analog (U, I, RTD, TC, R)

  • Output

    1 x analog (U, I)
    1 x transmitter power supply

  • Output

    1 x analog (U, I)
    1 x transmitter power supply

  • Software functions

    Pump control
    Linearisation
    Flow calculation
    Batch counter

  • Certificates

    FM AIS I,II,III/1/ABCDEFG
    CSA (Ex ia)I,II,III/1/ABCDEFG

  • SIL

    Not defined

  • Panel mounting

    panel mounting

  • Measuring principle

    Display

  • Function

    Display
    Power
    Switch
    Seperate
    Convert
    Count
    Calculate

  • Certification

    UL rec. Comp
    ATEX Ex i
    FM USA IS
    FM USA NI
    CSA IS
    CSA NI
    TIIS Ex ia

  • Input

    1 x analog (U, I, RTD, TC, R)

  • Output

    1 x analog (U, I)
    1 x transmitter power supply

  • Relay output

    4…8 x changeover contacts

  • Auxiliary power supply / Loop power supply

    90…250 V AC
    20…28 V AC
    20…36 V DC

  • Dimensions (wxhxd)

    Panel housing:
    96 x 96 x 161.3 mm
    (3.78″ x 3.78″ x 6.35″)

  • Software

    Pump control
    Linearisation
    Flow calculation
    Batch counter

  • Operation

    3 keys
    Interface RS252 + ReadWin2000

  • Display

    LCD multicolour
    Illuminated
    Bargraph

Field of application
The process measuring device monitors and displays the analog measured values. Pumps can be monitored using the digital status inputs. The RIA452 can supply connected two-wire sensors directly with power.

The RIA452 can supply connected two-wire sensors directly with power, optionally intrinsically safe. Up to eight freely programmable relays monitor the measured value for exceeding or falling below limit values. Other operating modes for the relays are sensor or device faults, batch and pump control functions (e.g. alternating pump control). In addition, the RIA452 can be used as a preset counter and for flow measurement in open channels and measuring weirs.

Benefits
7-digit 14-segment LC display, large bar graph with overrange and underrangeDigital status inputs for pump monitoringFlow measurement for open channels and weirsIntrinsically safe input with integrated loop power supplyMin/Max value savedLinearization table with up to 32 support points