Measuring principle
Conductive
-
Characteristic / Application
Triple rod probe with high-class media contacting wetted parts
-
Supply / Communication
Relay
-
Ambient temperature
-20 °C … 80 °C
(-4 °F … 176 °F) -
Process temperature
-40 °C … 150 °C
(-40 °F … 302 °F) -
Process pressure / max. overpressure limit
Vacuum … 30 bar
(Vacuum … 435 psi) -
Min. conductivity of medium
20 µS/cm
-
Main wetted parts
PTFE, PFA, 316 TI, Alloy B/C4, Titan, Tantal, Monel
-
Process connection
G 1 1/2A
NPT1 1/2″
Flange DIN /ASME -
Sensor length
0.1m … 4m
(4″ … 157″) -
Communication
Relay
-
Certificates / Approvals
ATEX, NEPSI
-
Components
Transmitter: FTW325
-
Application limits
Observe min. medium conductivity
Field of application
The triple rod probe 11363Z is a high resistant probe for applications requiring accurate point level detection or overfill prevention in plastic vessels or vessels made of non-conducting material. Three different limit points can be detected with one probe in vessels with electrically conducting walls.
Two-point point level detection in plastic vessels and vessels made of non-conducting material. For applications in explosion-hazardous areas or as overfill prevention for water-polluting liquids.
Process connections: Threads and flanges
Measuring range: 100 to 4,000mm (5.9 to 157″)
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +30bar (-15 to +435psi)
Components: Transmitter FTW325
International explosion protection certificates, overfill prevention WHG
Benefits
Reliable and safe measurementSafe measurement even for applications in explosion-hazardous areaVariable process connections for various applications