Measuring principle
Coriolis
-
Product headline
The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
-
Sensor features
Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
-
Transmitter features
Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
-
Nominal diameter range
DN 8 to 25 (⅜ to 1″)
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316) -
Measured variables
Mass flow, density, temperature, volume flow
-
Max. measurement error
Mass flow: ±0.5 % of batch
-
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
-
Max. process pressure
350 bar (5080 psi)
-
Medium temperature range
–50 to +125 °C (–58 to +257 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
-
Degree of protection
IP67, type 4X enclosure
-
Display/Operation
No local operation
Configuration via operating tools possible -
Outputs
Pulse/frequency/switch output (passive), phase‐shifted pulse
-
Inputs
None
-
Digital communication
Modbus RS485
-
Power supply
DC 10 to 30 V AC 20 to 28 V
-
Hazardous area approvals
ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
PTB, BEW, LNE, Rosstandart, NTEP approvals -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Measuring principle
Coriolis
-
Product headline
The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.
-
Sensor features
Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).
-
Transmitter features
Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
-
Nominal diameter range
DN 8 to 25 (⅜ to 1″)
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316) -
Measured variables
Mass flow, density, temperature, volume flow
-
Max. measurement error
Mass flow: ±0.5 % of batch
-
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
-
Max. process pressure