UV-VIS spectrometer for the water & wastewater industry
Ion-selective Memosens sensor for the wastewater industry
Total nitrogen analyzer for environmental monitoring, industrial and municipal wastewater
Colorimetric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers
Colorimetric system for online monitoring of drinking water and process water
Precise online TOC monitoring in the life sciences industry
Precise online TOC monitoring in power plants and semiconductor production
Potentiometric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers
For remote monitoring of a tank
The economical flowmeter for easy data transfer via USB stick without additional software
Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs
Device with automatic frequency scan for max. measuring performance and cost-effective transmitter
Refueling application flowmeter with easy system integration
The refueling and distribution application flowmeter with easy system integration
Refueling application flowmeter with seamless system integration
Compact sensor for smallest quantities with seamless system integration
Compact sensor for smallest quantities with easy system integration
The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics
Sensor with degree of protection IP68 (Type 6P enclosure) with a transmitter for custody transfer
The flowmeter for highest medium temperatures with a transmitter for custody transfer
Thermowell made of drilled barstock material. Mainly used in heavy duty or industrial applications
Thermowell with flanged process connections and round extension
Thermowell with threaded process connections and hexagonal extension
Thermowell with socket weld process connections and round extension
Thermowell with weld-in process connections and round extension
Compact and cost-saving for safe monitoring of process temperatures in hygienic applications
Compact and cost-saving for safe monitoring of process temperatures
Comprehensive and common temperature measurement technology for almost all branches of industry
Transformation of the sensor signals into stable and standardized output signal for all industries
Transformation of the sensor signal into a stable and standardized output signal for all industries
Transformation of the sensor signal into a stable and standardized output signal for all industries
Transformation of the sensor signal into a stable and standardized output signal for all industries
Cost efficient thermocouple sensor designed for use in many process and laboratory applications

Spectrometer Memosens Wave CAS80E

UV-VIS spectrometer for the water & wastewater industry

  • Measuring principle

    Absorption

  • Application

    Monitoring of WWTP in- and outlet
    Drinking water and surface water

  • Installation

    Insitu (immersion in process), extractive with sample and flow cell

  • Characteristic

    Insitu (immersion in process), extractive with sample and flow cell
    UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measurement range

    “Depending on the path length and the application the measuring range vary:
    TOCeq: 0 to 400 mg/l
    CODeq: 0 to 20 000 mg/l
    BODeq: 0 to 5000 mg/l
    SAC254: 0 to 1000 /m
    TU: 0 to 800 FAU
    TSS: 0 to 10 000 mg/l
    NO3-N: 0 to 500 mg/l
    APHA/Hazen: 0 to 500 Hazen

  • Measuring principle

    UV/VIS absorbance at 200 to 800 nm

  • Design

    40 mm

  • Material

    Housing: stainless steel or titanium
    Windows: sapphire or quartz
    O-rings: EPDM

  • Dimension

    571.4 x 40 mm
    21.5 x 1.6 in

  • Process temperature

    0 to 50°C
    32 to 122 °F

  • Process pressure

    0.5 to 10 bar abs.
    7.3 to 145 psi

  • Temperature sensor

    -20 to 60°C
    -4 to 140 °F

  • Connection

    G1 and NPT 3/4″

  • Ingress protection

    IP68

  • Measuring principle

    UV absorbance

  • Application

    Monitoring of WWTP in- and outlet, drinking water and surface water

  • Characteristic

    Insitu (immersion in process)
    Extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measurement range

    Depending on the path length and the application the measuring range vary:
    TOCeq: 0 to 400 mg/l
    CODeq: 0 to 20 000 mg/l
    BODeq: 0 to 5000 mg/l
    SAC254: 0 to 1000 /m
    TU: 0 to 800 FAU
    TSS: 0 to 10 000 mg/l
    NO3-N: 0 to 500 mg/l
    APHA/Hazen: 0 to 500 Hazen

  • Design

    40 mm

  • Material

    Housing: stainless steel or titanium
    Windows: sapphire or quartz
    O-rings: EPDM

  • Process temperature

    0 to 50°C
    32 to 122 °F

  • Process pressure

    0.5 to 10 bar abs.
    7.3 to 145 psi

  • Temperature sensor

    -20 to 60°C
    -4 to 140 °F

  • Connection

    G1 and NPT 3/4″

  • Ingress protection

    IP68

  • Measuring principle

    UV absorbance

  • Characteristic

    Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measuring method

    UV/VIS Absorbance at 200 to 800 nm

  • Size

    571.4 x 40 mm
    21.5 x 1.6 in

  • Design

    40 mm

Digital ammonium and nitrate sensor ISEmax CAS40D

Ion-selective Memosens sensor for the wastewater industry

  • Measuring principle

    Potentiometric / ISE

  • Characteristic

    Online measurement of nutrient parameters in
    municipal wastewater treatment plants
    Ion-selective electrode system for the continuous measurement of
    ammonium and nitrate

  • Size

    Diameter: 112 mm (4.41 inch)
    Immersion depth: 510mm (20.08 inch)

  • Design

    Ion-selective electrode(s) for ammonium and/or nitrate, potassium or chloride
    pH – (Reference) electrode
    Ion-selective electrode for compensating cross-interference
    Temperature sensor

  • Process temperature

    2 °C to 40°C (36 to 100 °F)

  • Ambient temperature

    -20 °C to 50 °C (-4 to 120 °F)

  • Process pressure

    400 mbar (160 in H2O) max. permitted overpressure

  • Application

    Wastewater treatment plants

  • Measurement range

    Ammonium:
    0.1 to 1000 mg/l (NH4-N)
    Nitrate:
    0.1 to 1000 mg/l (NO3-N)
    Potassium:
    1 to 1000 mg/l
    Chloride:
    1 to 1000 mg/l

Field of application
ISEmax CAS40D is the right technology for trend measurement directly in the basin. It helps you to increase the efficiency and reduce the energy costs of your aeration processes. The sensor works without reagents saving you even further money. With its robust ion-selective membranes and excellent self-cleaning, it eases your maintenance tasks. Thanks to Memosens, CAS40D combines maximum process and data integrity with best operating comfort and simplifies predictive maintenance.

ISEmax CAS40D measures ammonium, nitrate and pH in municipal wastewater treatment plants:
Aeration basins- Determination of ammonium and nitrate concentration- Control and regulation of ammonium decomposition- Load-dependent aeration control for optimization of the treatment process
Inlet of aeration basins- Determination of ammonium load (pH-compensated)

Benefits
Nitrate and ammonium measured directly without the need for expensive sample conditioningOptional potassium and/or chloride measurement compensates for cross sensitivities and ensures reliable measuring resultsLow maintenance thanks to automatic flushing unitInstalled directly on the basin rim, no measuring container or sample-conveying pump requiredEasy handling due to storage of sensor-specific data

TN analyzer Liquiline System CA80TN

Total nitrogen analyzer for environmental monitoring, industrial and municipal wastewater

  • Measuring principle

    UV photometric

  • Characteristic

    Process analyzer for total nitrogen in aqueous solutions
    UV photometric method following HJ636-2012

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 15 ml/min (0.51 fl.oz/min)

  • Consistency of the sample

    Aqueous, homogeneous

  • Application

    Monitoring of wastewater treatment plant outlet
    Monitoring of the surface water quality
    Monitoring of industrial water treatment
    Monitoring and optimization of industrial wastewater treatment plants

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Webserver (optional)
    Ethernet/IP
    Profibus DP
    Alarm relay

  • Input

    1 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0 to 10 mg/l N
    0 to 50 mg/l N
    0 to 200 mg/l N

  • Consumables

    Reagents and standard solutions CY80TN as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV880

Field of application
Nitrogen is a lead parameter to determine surface water quality and wastewater effluent values. Both, organic and inorganic substances contribute to the total nitrogen load. Increased nitrogen contents indicate influences from wastewater, landfill leachate or agriculture.Liquiline System CA80TN analyzer offers precise online measurement of total nitrogen and ensures highest process safety. Advanced diagnostics with remote access support you in providing process documentation to the authorities.

The Liquiline System TN analyzer monitors organic (e.g. proteins, urea) and inorganic (e.g. nitrate, nitrite, ammonium) nitrogen compounds in the following applications:Inlet and outlet of wastewater treatment plants for documentation and calculation of the cleaning capacityDischarges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principleMonitoring of surface water quality

Benefits
Standardized alkaline persulfate digestion and UV-photometric measurement according to HJ636 offer direct comparability to most cuvette tests.Robust: Titanium reactor with sapphire glass windows ensures a long lifetime. Flexible: Integrated dilution module covers a wide measuring range. Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications. Easy upgrade to a complete measuring station – simply by adding modules and connecting Memosens sensors.

Silica analyzer Liquiline System CA80SI

Colorimetric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for silica in aqueous solutions

  • Measuring method

    Comply with standard colorimetric measuring principle – heteropoly blue method

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design / cabinet
    Plastic ASA-PC

  • Process temperature

    5 to 45 °C (41 to 113 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

  • Process pressure

    1 to 5 bar (14.5 to 72.5 psi)

  • Sample flow rate

    60 to 250 ml/min (2.03 to 8.45 fl.oz/min)

  • Consistency of the sample

    Particle free

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    optional up to 6 sample channels
    Flexible functionality and modular expandable
    Digital communication for remote access

  • Application

    Determination of silica concentration in boiler feed water
    Monitoring of water-steam-circuit and condensate
    Monitoring and optimization of reverse osmosis and desalination

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    50 ± 1 or 60 ± 1.2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Optional: Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1, 2, 4 or 6 measuring channels
    Optional 1 to 4 digital inputs for sensors with Memosens protocol

  • Measurement range

    0 to 500 µg/l (ppb)
    50 to 5000 µg/l (ppb)

  • Consumables

    Reagents and standard solutions CY80SI
    Maintenance kit CAV800

Field of application
Liquiline System CA80SI provides precise online analysis of silica and helps protect plant equipment from glass-like deposits ensuring optimum performance of turbines and ion exchangers. Its unique combination of peristaltic and high-precision dispenser pumps enables extremely reliable operation and low maintenance. The silica analyzer offers advanced diagnostics and can be easily adapted to your process needs by retrofitting up to 6 channels and connecting up to 4 Memosens sensors.

The CA80SI silica analyzer monitors trace levels of silica in the power industry and utilities:Indication of the purity of boiler feed water and steamProvision of early warning for condenser leaksEarly warning of exhaustion of ion exchangers

Benefits
Protection of expensive plant equipment in the power industry: The silica analyzer monitors trace levels of silica in water steam cycles helping to avoid glass-like deposits on the equipment surfaces.Early online detection of critical silica levels ensures efficient power plant performance and optimizes maintenance and blowdown cycles by early counter measures. Standard heteropoly blue method allows direct comparability to lab results.Best reliability: Unique combination of peristaltic and high-precisions dispenser pumps ensures stable operation and low maintenance. Optimized investment: The option of up to 6 sample channels meets changing process needs at any time, and connection of Memosens sensors allows an easy upgrade to a complete measuring station. Seamless integration into process control systems thanks to digital field buses such as Modbus, EtherNet/IP or PROFIBUS. Advanced diagnostics and remote access via web server enable fast remedy in case of errors.

Water hardness analyzer Liquiline System CA80HA

Colorimetric system for online monitoring of drinking water and process water

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for hardness in aqueous solutions
    Comply with standard colorimetric measuring principle – phthalein purple method

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

  • Process pressure

    Unpressurized

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Low solid content (< 50NTU), aqueous homogeneous

  • Application

    Total hardness monitoring in reverse osmosis systems inlets, after ion exchange systems
    Monitoring of water preparation in processes and drinking water

  • Power supply

    100 … 120 VAC / 200 … 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 oder 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 … 20 mA
    Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channel
    1 … 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0 to 80 mg/l CaCO3
    0 to 80 mg/l with dilution function to maximum 16 to 1600 mg/l CaCO3

  • Consumables

    Reagents and standard solutions CY80HA as well as cleaner CY800 are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Field of application
Liquiline System CA80HA offers precise online analysis of water hardness in drinking water and process water. It helps you optimize the control of water softening processes such as ion exchange or reverse osmosis and ensures optimal quality of products that are influenced by water hardness. The analyzer’s automatic calibration and cleaning and its low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure consistent process safety.

Liquiline System CA80HA supports you in monitoring total water hardness: To optimize reverse osmosis and ion exchanger systems To classify water hardness in drinking waterTo ensure process water quality in production plants

Benefits
The water hardness analyzer uses the phthalein purple method, ensuring direct comparability to lab results Fast commissioning with plug & play thanks to Memosens technology and user-friendly operation Reduces operating costs thanks to automatic calibration and cleaning, low reagent consumption and long reagent lifetime with optional cooling module Easy upgrade of functionality to a complete measuring station – by adding modules and connecting Memosens sensors. Advanced diagnostics with remote access for increased process safety Easy, tool-free maintenance

Low-range TOC analyzer CA79

Precise online TOC monitoring in the life sciences industry

  • Measuring principle

    Differential conductivity

  • Characteristic

    Total carbon (TOC) analyzer for trace levels

  • Measuring method

    TOC determination by UV digestion and measurement of the differential conductivity

  • Size

    Housing:
    500 x 290 x 200 mm
    19.68 x 11.41 x 7.87 in

  • Design

    Stainless steel housing;
    IP 42 (standard), IP54 (optional)

  • Process temperature

    < 50 °C (122 °F)

  • Ambient temperature

    10 to 45 °C (50 to 113 °F)

  • Process pressure

    max. 0.5 bar (7.25 psi)

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    max. conductivity 2 μS/cm, particle free

  • Specials

    The operating concept and data storage meet the requirements of 21 CFR, Part 11
    UV reactor with continuous function monitoring

  • Application

    Determination of total carbon in ultrapure water applications, e.g. in the lifescience industry, that meet the following conditions:
    Conductivity < 2 μS/cm
    pH range: neutral

  • Power supply

    100/240 V AC, 47 – 63 Hz

  • Output / communication

    0/4 to 20 mA, galvanically isolated

  • Input

    1 to optional 3 measuring channels
    Optional control input 24 V (for 1 channel instruments)

  • Measurement range

    0.5 to 1 000 μg/l (ppb)

Field of application
The total organic carbon (TOC) content is an important quality parameter in the production and use of ultrapure water. If the TOC content is too high, the performance of water purification systems can be impaired or pharmaceutical batches can even be contaminated. The CA79 online TOC analyzer provides continuous, accurate TOC monitoring of your water for injection (WFI). Your product batches can be produced safely and in compliance with regulations.

The CA79 TOC analyzer is perfectly suited for TOC monitoring of ultrapure water in life sciences applications with the following process conditions:Conductivity < 2 µS/cmneutral pH range

Benefits
Real-time overview of water quality: The CA79 TOC analyzer measures continuously providing a fast response time (t90) of 50 seconds. This enables you to react immediately and to protect your product effectively.The online analyzer uses proven UV oxidation and differential conductivity measurement which has become the most-established method for TOC trace analysis in ultrapure water.Compliance:CA79 meets the requirements of the European and US Pharmacopeias and allows working according to FDA 21 CFR Part 11. CA79 provides clear documentation of relevant events, regular quality reports and system suitability tests (SSTs).The analyzer’s maintenance-friendly design in combination with our worldwide service network offers you complete support for the measuring point, including the installation qualification (IQ) and regular operational qualifications (OQ).

Low-range TOC analyzer CA78

Precise online TOC monitoring in power plants and semiconductor production

  • Measuring principle

    Differential conductivity

  • Characteristic

    Total carbon (TOC) analyzer for trace levels

  • Measuring method

    TOC determination by UV digestion and measurement of the differential conductivity

  • Size

    Housing:
    500 x 290 x 200 mm
    19.68 x 11.41 x 7.87 in

  • Design

    Stainless steel housing;
    IP 42 (standard), IP54 (optional)

  • Process temperature

    < 50 °C (122 °F)

  • Ambient temperature

    10 to 45 °C (50 to 113 °F)

  • Process pressure

    max. 0.5 bar (7.25 psi)

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    max. conductivity 2 μS/cm, optional: max. 10 μS/cm; particle free

  • Specials

    UV reactor with continuous function monitoring

  • Application

    Determination of total carbon in ultrapure water applications, e.g. in the power or semiconductor industry, that meet the following conditions:
    Conductivity < 10 μS/cm
    pH range: neutral

  • Power supply

    100/240 V AC, 47 – 63 Hz

  • Output / communication

    0/4 to 20 mA, galvanically isolated

  • Input

    1 to optional 3 measuring channels
    Optinonal control input 24 V (for 1 channel instruments)

  • Measurement range

    0.5 to 1 000 μg/l (ppb)

Field of application
Total organic carbon (TOC) content strongly influences the quality of ultrapure water. A high TOC concentration can cause damage of water purification systems or compromise the required water quality. The CA78 online TOC analyzer provides continuous, accurate TOC monitoring ensuring consistently high quality of the ultrapure water used in your production processes. You gain full control of your product yield and quality.

The CA78 TOC analyzer is perfectly suited to TOC monitoring of ultrapure water in the following industries: Power & EnergySemiconductor productionBodycareDisinfectant productionWith the following process conditions:Conductivity: 2 µS/cm (standard), 10 µS/cm (order option)pH range: Neutral

Benefits
Real-time overview of water quality: The online TOC analyzer measures continuously with a fast response time (t90) of 50 seconds. This enables you to react immediately to potential water contamination and to protect your product effectively.CA78 uses proven UV oxidation and differential conductivity measurement which is the most-established method for reliable TOC trace analysis in ultrapure water.The analyzer’s maintenance-friendly design in combination with our worldwide service network offers you complete support for the measuring point, from commissioning throughout the entire lifespan of the device.Perfect adaption to your process needs:Select between the high-precision 2 µS/cm conductivity version and the robust version that tolerates 10 µS/cm. Reduce your investment costs by the optional 3 channel configuration.

Sodium analyzer CA76NA

Potentiometric system for the monitoring of boiler feedwater, steam, condensate and ion exchangers

  • Measuring principle

    Potentiometric / ISE

  • Characteristic

    Analyser for sodium in boiler feedwater, steam, condensate and ion exchangers

  • Size

    850 x 450 x 250 mm
    33.5 x 17.7 x 9.8 inch

  • Design

    Panel stainless steel 1.4301

  • Process temperature

    10 to 40 °C
    (50 to 104 °F)

  • Ambient temperature

    5 to 40 °C
    (41 to 104 °F)

  • Process pressure

    1 to 5 bar (abs)
    14.5 to 72.5 psi

  • Sample flow rate

    10 to 15 l/h
    2.64 to 3.96 gal/h

  • Application

    Online sodium monitoring in boiler feed water, water steam cycles, condensate and ion exchangers

  • Power supply

    100 to 240 V AC, 50/60 Hz

  • Output / communication

    0/4 to 20 mA

  • Measurement range

    0.1 to 9999 µg/l (ppb) Na

  • Consumables

    CA76NA sodium electrode,
    CA76NA pH combination electrode
    CA76NA standard solution 5100 ppb Na

Field of application
Protect your water steam cycles and ion exchangers with the CA76NA sodium analyzer! An increase in sodium levels in high-purity or boiler feedwater indicates the presence of unwanted dissolved impurities. This can cause serious damage and consequently expensive repairs. CA76NA provides highly accurate online monitoring of water quality and enables fast detection of critical events. The sodium analyzer supports your preventive maintenance strategy to keep your power plant running.

The CA76NA sodium analyzer monitors low levels of sodium in the power industry and utilities:Indication of the purity of water and steam used in boilers and turbines.Provision of early warning for condenser leakages or malfunction of ion exchangers.Control of the incoming water quality in power plants that use desalination plants as water source.

Benefits
Protection of expensive plant equipments in the power industry: CA76NA sodium analyzer monitors low levels of sodium in water steam cycles detecting carryover and impurities in your power plant.Early indication of condenser leaks via online sodium measurement after the condensate extraction pump. Reduced operating costs thanks to low consumption of DIPA reagent and standard solution. Precise measurement: Separate reference pH electrode for accurate temperature compensation and optimized pH value adjustment. Optimized investment costs: One analyzer for up to six sample channels.Perfect process adaptation: Individual selection of sample channels and freely adjustable measuring intervals.

Tank gauging Analogue Transmitter AT1

For remote monitoring of a tank

Field of application
The AT1 transmitter is designed to attach to the LT5 level gauge. Main functions are 4 to 20mA analogue output and alarm contact output.

Ambient temperature: -20 to +60°C (-4 to +140°F)

Benefits
Transmission of the tank level by analogue signals Max. 6 alarm contact outputsEasy maintenance due to simple mechanism

Proline Prosonic Flow 93T ultrasonic flowmeter

The economical flowmeter for easy data transfer via USB stick without additional software

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Portable volume flowmeter for measurement of liquid applications; from outside of the pipe with “Clamp On” sensors

  • Sensor features

    Integrated USB data logging

  • Nominal diameter range

    DN 15…65
    – 1/2″…2 1/2″ (-40…+100°C or -40…+150 °C)
    DN 50…300
    – 2″…12″ -40…+80 °C or 0…+170 °C)
    DN 100…4000
    – 4″…160″ (-40…+80 °C)

  • Max. measurement error

    +/-2.0 %

  • Measuring range

    0….452’389 m3/h

  • Max. process pressure

    No limit

  • Medium temperature range

    DN 15…65
    -40…+150°C
    (-40…+302°F)
    DN 50…300
    -40…+170°C
    (-40…+338°F)
    DN 100…4000
    -40…+80°C
    (-40…+176°F)

  • Degree of protection

    IP 40

  • Display/Operation

    Four line backlit
    touch control

  • Outputs

    Integrated data logger/site manager
    Easy data transfer via USB stick without additional software

  • Inputs

    4…20mA

  • Digital communication

    FXA 193

Field of application
The portable ultrasonic flowmeter Prosonic Flow 93T is designed for temporary monitoring and test measurements with clamp on sensors. It is operated independently of the mains power using a battery. The Prosonic Flow 93T is ideal for conducting verification measurements at existing flow metering points.

The sensors are perfectly suited for the non-contact measurement of pure or slightly contaminated liquids, regardless of the pressure or electrical conductivity.
Ideal solution for temporary use everywhere precise measurement or verification is required
Can be used with all metal and plastic pipes lined or unlined and with composite pipes
Suitable for pipe diameters from DN 15 to 4000 (½ to 160″)
Suitable for fluid temperatures ranging from –40 to +170 °C (–40 to +338 °F)

Benefits
Automatic frequency scan for maximum measuring performanceQuick and secure installation – specially designed mounting kitsNo additional leakage paths – external measurement from outside the pipeProcess transparency – diagnostic capabilityTemporary monitoring of measuring points – portable flowmeter with rechargeable battery and current outputVerification of other flow devices – integrated data logger and current inputAutomatic recovery of data

Proline Prosonic Flow 92F ultrasonic flowmeter

Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
    Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.

  • Sensor features

    Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
    Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12″). Medium temperature: –40 to 200 °C (–40 to 392 °F).

  • Transmitter features

    Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI. Automatic recovery of data for servicing.
    Device as compact or remote version. 2-line backlit display with push buttons. HART, PROFIBUS PA, FOUNDATION Fieldbus.

  • Nominal diameter range

    2 path version: DN80 to 300 (3 to12″)
    3 path version: DN25 to 50 (1 to 2″)
    4 path version: DN 80 to 300 (3 to 12″)

  • Wetted materials

    Sensor:
    A351-CF3M (DN25 to 100)
    1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
    Transducer: 1.4404/316/316L
    Flanges : 1.4404/316/316L or A105/1.0432

  • Measured variables

    Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength

  • Max. measurement error

    Volume flow (standard):
    – ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
    Volume flow (option):
    – ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

  • Measuring range

    0.5 to 10 m/s (1.6 to 33 ft/s)

  • Max. process pressure

    PN 40 / ASME Cl. 300 / JIS 20K

  • Medium temperature range

    -40 to +150 °C (-40 to +302 °F)
    -40 to +200 °C (-40 to +392 °F) optional

  • Ambient temperature range

    -40 to +60 °C (-40 to +140 °F) compact
    -40 to +80 °C (-40 to +176 °F) remote sensor
    -40 to +60 °C (-40 to +140 °F) remote transmitter

  • Transmitter housing material

    AlSi10Mg, coated

  • Degree of protection

    IP67, type 4X enclosure
    IP68 type 6P enclosure (option for remote)

  • Display/Operation

    2 lines backlit display with 3 push buttons

  • Outputs

    1x 4-20 mA HART
    1x Pulse/frequency/switch output (passive)

  • Inputs

    N/A

  • Digital communication

    HART, Profibus PA, FOUNDATION Fieldbus

  • Power supply

    2 wire loop powered

  • Hazardous area approvals

    ATEX,FM, CSA, JPNm UK Ex

  • Other approvals and certificates

    3.1 material (wetted parts), calibration performed on accredited
    calibration facilities (acc. to ISO/IEC 17025), CRN, AD2000
    PED, EAC marking

  • Product safety

    EAC marking

  • Metrological approvals and certificates

    calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    CRN, PED, AD2000

  • Material certificates

    3.1 material (wetted parts)

Field of application
Prosonic Flow F is the sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.

The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12″)
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus

Benefits
Safe design for process industries – international hazardous area approvalsNo additional pressure loss – full-bore designProcess transparency – diagnostic capabilityEasy installation and reduced installation costs – loop-powered transmitterFully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSIAutomatic recovery of data for servicing

Proline Prosonic Flow 91W ultrasonic flowmeter

Device with automatic frequency scan for max. measuring performance and cost-effective transmitter

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Device with automatic frequency scan for maximum measuring performance and cost-effective transmitter.
    Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.

  • Sensor features

    Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80″). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability.
    Medium temperature: –20 to +80 °C (-4 to +176 °F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6.

  • Transmitter features

    Economical transmitter – designed for easy applications. Fast and reliable commissioning – Quick Setup menu for installation. Automatic recovery of data for servicing.
    Aluminium field transmitter housing. 2-line display with push buttons. HART.

  • Nominal diameter range

    Single channel, 1 or 2 paths : DN15 to 2000 (1/2 to 80″)

  • Wetted materials

    Clamp on system:
    Sensor holder 1.4308/CF-8
    Sensor housing 1.4301/304
    Strapping bands 1.4301/304

  • Measured variables

    Volume flow, sound velocity, flow velocity, signal strength, totalizer

  • Max. measurement error

    Volume flow:
    ±3% o.r. for DN15
    ±2% o.r. for DN25 to 200
    ±2% o.r. above DN200

  • Measuring range

    0.3 to 10 m/s (1 to 33 ft/s)

  • Max. process pressure

    N/A

  • Medium temperature range

    -20 to +80°C (-4 to +176 °F)
    0 to +130°C (32 to +265 °F) option

  • Ambient temperature range

    -20 to +60 °C (-4 to +140 °F)

  • Sensor housing material

    N/A

  • Transmitter housing material

    AlSi10Mg, coated

  • Degree of protection

    IP67, type 4X for transmitter
    IP67 type 4X for sensors
    IP68 type 6P for sensors (option). IP67 NEMA 4X

  • Display/Operation

    2 lines backlit display with 3 push button

  • Outputs

    1x 4-20 mA HART (active)
    1x Pulse/frequency/switch output (passive)

  • Inputs

    N/A

  • Digital communication

    HART

  • Power supply

    AC 85 to 250 V
    20 to 28 V
    DC 11 to 40 V

  • Hazardous area approvals

    Non hazardous area
    FM, CSA

  • Other approvals and certificates

    Flowmeter verification for DN15, 25, 40, 50 & 100 only
    EAC marking

  • Product safety

    CE, C-Tick, EAC marking

  • Metrological approvals and certificates

    Flowmeter verification for DN15, 25, 40, 50 & 100 only

Field of application
The Prosonic Flow W clamp-on sensor is specially designed for water and wastewater applications. Combined with the cost-effective Prosonic Flow 91 transmitter with push buttons, Prosonic Flow 91W is ideally suited for flow monitoring in the water industry.

The measuring principle is independent of pressure, density, temperature, conductivity and viscosityClamp-on flow measurement of process water, salt water, deminerialized water, drinking & wastewater.Device properties:Medium temperature: –20 to +80 °C (-4 to +176 °F)Degree of protection IP68 (Type 6P enclosure) for pipes under waterShock and vibration resistance according to IEC 68-2-6Aluminium field transmitter housing2-line display with push buttonsHART

Benefits
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000)Long-term stable signal – maintenance-free permanent mounting from outside with coupling padsProcess transparency – diagnostic capabilityEconomical transmitter – designed for easy applicationsFast and reliable commissioning – Quick Setup menu for installationAutomatic recovery of data for servicing

CNGmass Coriolis flowmeter

Refueling application flowmeter with easy system integration

  • Measuring principle

    Coriolis

  • Product headline

    The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

  • Sensor features

    Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

  • Transmitter features

    Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.

  • Nominal diameter range

    DN 8 to 25 (⅜ to 1″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4404 (316)

  • Measured variables

    Mass flow, density, temperature, volume flow

  • Max. measurement error

    Mass flow: ±0.5 % of batch

  • Measuring range

    0 to 150 kg/min (0 to 330 lb/min)

  • Max. process pressure

    350 bar (5080 psi)

  • Medium temperature range

    –50 to +125 °C (–58 to +257 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure

  • Display/Operation

    No local operation
    Configuration via operating tools possible

  • Outputs

    Pulse/frequency/switch output (passive), phase‐shifted pulse

  • Inputs

    None

  • Digital communication

    Modbus RS485

  • Power supply

    DC 10 to 30 V AC 20 to 28 V

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    PTB, BEW, LNE, Rosstandart, NTEP approvals

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Measuring principle

    Coriolis

  • Product headline

    The refueling application flowmeter with easy system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

  • Sensor features

    Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Spacesaving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

  • Transmitter features

    Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.

  • Nominal diameter range

    DN 8 to 25 (⅜ to 1″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4404 (316)

  • Measured variables

    Mass flow, density, temperature, volume flow

  • Max. measurement error

    Mass flow: ±0.5 % of batch

  • Measuring range

    0 to 150 kg/min (0 to 330 lb/min)

  • Max. process pressure

    350 bar (5080 psi)

LPGmass Coriolis flowmeter

The refueling and distribution application flowmeter with easy system integration

  • Measuring principle

    Coriolis

  • Product headline

    The refueling and distribution application flowmeter with easy sytem
    integration. Accurate measurement of liquefied petroleum gas in refueling
    and distribution applications.

  • Sensor features

    Excellent operational safety – reliable under extreme ambient conditions.
    Fewer process measuring points – multivariable measurement (flow,
    density, temperature). Space‐saving installation – no in/outlet run needs.
    Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation
    according to API table 53.

  • Transmitter features

    Easy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.

  • Nominal diameter range

    DN 8 to 40 (³⁄₈ to 1½”)

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow

  • Max. measurement error

    Mass flow (liquid): ±0.2 %
    Volume flow (liquid): ±0.3 %

  • Measuring range

    0 to 45 000 kg/h (0 to 1650 lb/min)

  • Max. process pressure

    PN 40, Class 300, 63K

  • Medium temperature range

    –40 to +125 °C (–40 to +257 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure

  • Display/Operation

    No local operation
    Configuration via operating tools possible

  • Outputs

    Pulse/frequency/switch output (passive), phase‐shifted pulse

  • Inputs

    None

  • Digital communication

    Modbus RS485

  • Power supply

    DC 10 to 30 V
    AC 20 to 28 V

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody
    transfer
    PED, CRN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

Field of application
The LPGmass is specially designed for flow measurement of LPG for dispensing and truck unloading. It combines an integrated temperature measurement with intelligent conversion functions, providing volume correction directly on site. LPGmass will be the preferred choice for system integrators, skid builders and equipment manufacturers.

Measuring principle operates independently of physical fluid properties such as viscosity or density
Accurate measurement of liquefied petroleum gas in refueling and distribution applications.

Device properties
Flow rates up to 45 000 kg/h (1654 lb/min)
Volume flow calculation according to API table 53
Worldwide metrological approvals
Robust, ultra-compact transmitter housing
Pulse output and Modbus RS485
Transmitter for custody transfer

Benefits
Excellent operational safety – reliable under extreme ambient conditionsFewer process measuring points – multivariable measurement (flow, density, temperature)Space-saving installation – no in/outlet run needsEasy operation – reduced to application needsFast commissioning – pre-configured devices Automatic recovery of data for servicing

CNGmass DCI Coriolis flowmeter

Refueling application flowmeter with seamless system integration

  • Measuring principle

    Coriolis

  • Product headline

    The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

  • Sensor features

    Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs and Modbus RS485.

  • Nominal diameter range

    DN 8 to 25 (⅜ to 1″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4404 (316)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density

  • Max. measurement error

    Mass flow: ±0.5 % of batch

  • Measuring range

    0 to 150 kg/min (0 to 330 lb/min)

  • Max. process pressure

    350 bar (5080 psi)

  • Medium temperature range

    –50 to +150 °C (–58 to +302 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive), phase‐shifted pulse
    Relay

  • Inputs

    1 modular input: status

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, NEPSI, JPN

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
    CRN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer

  • Pressure approvals and certificates

    CRN

  • Material certificates

    3.1 material

  • Measuring principle

    Coriolis

  • Product headline

    The refueling application flowmeter with seamless system integration. Accurate measurement of compressed natural gas (CNG) in high pressure refueling applications.

  • Sensor features

    Excellent operational safety – reliable under extreme process conditions. Fewer process measuring points – multivariable measurement (flow, density, temp). Space‐saving installation – no in/outlet run needs. Flow rates up to 150 kg/min (330 lb/min). Process pressure up to 350 bar (5080 psi).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – preconfigured devices. Automatic recovery of data for servicing. Device in compact or remote version. Flexible outputs and Modbus RS485.

  • Nominal diameter range

    DN 8 to 25 (⅜ to 1″)

  • Wetted materials

    Measuring tube: 1.4435 (316L)
    Connection: 1.4404 (316)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density

  • Max. measurement error

    Mass flow: ±0.5 % of batch

  • Measuring range

    0 to 150 kg/min (0 to 330 lb/min)

Cubemass DCI Coriolis flowmeter

Compact sensor for smallest quantities with seamless system integration

  • Measuring principle

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with seamless system integration.
    Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
    Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
    Device as compact or remote version. Flexible outputs. Modbus RS485.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”)

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4 modular outputs:
    0‐20 mA (active)/4‐20 mA (active/passive)
    Pulse/frequency/switch output (passive), phase‐shifted pulse
    Relay

  • Inputs

    1 modular input: status

  • Digital communication

    HART, Modbus RS485

  • Power supply

    DC 16 to 62 V
    AC 85 to 260 V (45 to 65 Hz)
    AC 20 to 55 V (45 to 65 Hz)

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
    CRN

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Material certificates

    3.1 material

  • Measuring principle

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with seamless system integration.
    Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
    Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).

  • Transmitter features

    High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
    Device as compact or remote version. Flexible outputs. Modbus RS485.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”)

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

Cubemass Coriolis flowmeter

Compact sensor for smallest quantities with easy system integration

  • Measuring principle

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with easy system integration.
    Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
    Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).

  • Transmitter features

    Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
    Robust transmitter housing. Modbus RS485. Pulse output.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”)

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

  • Medium temperature range

    –50 to +200 °C (–58 to +392 °F)

  • Ambient temperature range

    Standard: –20 to +60 °C (–4 to +140 °F)
    Option: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Powder‐coated die‐cast aluminium

  • Degree of protection

    IP67, type 4X enclosure

  • Display/Operation

    No local operation
    Configuration via operating tools possible

  • Outputs

    Pulse/frequency/switch output (passive), phase‐shifted pulse

  • Inputs

    None

  • Digital communication

    Modbus RS485

  • Power supply

    DC 10 to 30 V
    AC 20 to 28 V

  • Hazardous area approvals

    ATEX, IECEx, NEC/CEC, NEPSI

  • Other approvals and certificates

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    CRN

  • Metrological approvals and certificates

    3.1 material

  • Pressure approvals and certificates

    CRN

  • Measuring principle

    Coriolis

  • Product headline

    Compact sensor for smallest quantities with easy system integration.
    Measuring accurately smallest quantities of liquids and gases.

  • Sensor features

    Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor.
    Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).

  • Transmitter features

    Cost savings – very low power consumption. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing.
    Robust transmitter housing. Modbus RS485. Pulse output.

  • Nominal diameter range

    DN 1 to 6 (¹⁄₂₄ to ¹⁄₄”)

  • Wetted materials

    Measuring tube: 1.4539 (904L)
    Connection: 1.4539 (904L); 1.4404 (316/316L)

  • Measured variables

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Max. measurement error

    Mass flow (liquid): ±0.1 %
    Volume flow (liquid): ±0.1 %
    Mass flow (gas): ±0.5 %
    Density (liquid): ±0.0005 g/cm3

  • Measuring range

    0 to 1000 kg/h (0 to 37 lb/min)

  • Max. process pressure

    PN 40, Class 300, 10K, 400 bar (5800 psi)

Proline Promag 55S electromagnetic flowmeter

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
    Superb signal stability due to unique signal processing.
    Ideal for the most demanding applications with high solids content and high abrasion.

  • Sensor features

    Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Intensified coil system. Large range of liners. Solids content up to 80 % by weight.

  • Transmitter features

    Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing.
    4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

  • Nominal diameter range

    DN 15…600
    1/2″…24″

  • Wetted materials

    Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
    Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

  • Measured variables

    Volume flow, electrical conductivity, mass flow

  • Max. measurement error

    Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
    Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)

  • Max. process pressure

    PN 40, Cl. 300, JIS 20 K

  • Medium temperature range

    0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    Aluminum coated AlSi10Mg, carbon steel with protective varnish

  • Transmitter housing material

    Powder-coated die-cast aluminum

  • Degree of protection

    Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
    Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor

  • Display/Operation

    Liquid-crystal display: illuminated, four lines with 16 characters per line
    Onsite operation with three optical sensor keys

  • Outputs

    4…20mA
    (active/passive) Pulse-/ Frequency output (active/passive)
    Two status outputs

  • Inputs

    Status
    Current input

  • Digital communication

    HART, PROFIBUS DP/PA, FOUNDATION Fieldbus

  • Power supply

    AC 20 to 260 V
    DC 20 to 64 V

  • Hazardous area approvals

    ATEX, FM, CSA, UK Ex

  • Product safety

    CE, C-tick, EAC marking

  • Pressure approvals and certificates

    CRN, PED

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920

Field of application
Promag S is the specialist for inhomogeneous, abrasive and corrosive fluids. The robust sensor design, featuring industry-optimized liners, enables its use in most challenging surroundings and metering jobs such as sewage treatment, pulp and paper production or in the primaries and metals industry. Due to its high-performance transmitter, Promag 55S not only measures flow reliably, but also calculates solids content at low maintenance requirements.

The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityIdeal for the most demanding applications with high solids content and high abrasion.Device propertiesIntensified coil systemLarge range of linersSolids content up to 80 % by weight4-line backlit display with touch controlTwo switch outputsHART, PROFIBUS PA/DP, FOUNDATION Fieldbus

Benefits
Superb signal stability due to unique signal processingMaximum safety – industry-optimized measuring electrodes and liningsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsHighest performance – with integrated solids measurement for demanding fluidsHighest safety – integrated electrode cleaningAutomatic recovery of data for servicing

Proline Promag 51W electromagnetic flowmeter

Sensor with degree of protection IP68 (Type 6P enclosure) with a transmitter for custody transfer

  • Measuring principle

    Electromagnetic

  • Product headline

    The sensor with degree of protection IP68 (Type 6P enclosure) combined with a transmitter for custody transfer. The specialist in the water and wastewater industry for the most demanding applications.

  • Sensor features

    Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance-free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).

  • Transmitter features

    Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. Transmitter certified to MI‐001. Device in compact or remote version.

  • Nominal diameter range

    DN 25…2000
    1″…78″

  • Max. measurement error

    ±0.5%
    ±0.2% (optional)

  • Measuring range

    0…110’000 m3/h

  • Max. process pressure

    PN6…40

  • Medium temperature range

    -20…+80°C
    (-4…176°F)

  • Ambient temperature range

    -20…+60°C
    -40…+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Two line display with backlit
    Push button

  • Outputs

    4…20 mA
    Pulse/Frequency
    Status

  • Inputs

    Status

  • Digital communication

    HART

  • Hazardous area approvals

    ATEX

  • Product safety

    CE, C-tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025),
    Custody transfer approvals: MI-001, PTB

  • Pressure approvals and certificates

    PED

Field of application
Promag W is the specialized sensor for all applications in the water industry. Combined with the proven Promag 51 transmitter with push buttons, Promag 51W offers highly accurate measurement of liquids for a wide range of standard applications. it will be the preferred solution for customers needing custody transfer measurement Promag 51W is available in a compact or remote version.

The measuring principle is virtually independent of pressure, density, temperature and viscosityThe specialist in the water and wastewater industry for the most demanding applications.Device propertiesInternational drinking water approvalsDegree of protection IP68 (Type 6P enclosure)Approved for custody transfer to MI-001/OIML R49Transmitter certified to MI-001Device in compact or remote versionHART

Benefits
Secure, reliable long-term operation – robust and completely welded sensorEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsQuality – designed for custody transfer; featuring worldwide recognized metrological approvalsSafe operation – display provides easy readable process informationFully industry compliant – IEC/EN/NAMUR

Proline Promag 51P electromagnetic flowmeter

The flowmeter for highest medium temperatures with a transmitter for custody transfer

  • Measuring principle

    Electromagnetic

  • Product headline

    The flowmeter for highest medium temperatures with a transmitter for custody transfer. Dedicated for chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Versatile applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24″). All common Ex approvals.

  • Transmitter features

    Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. Transmitter certified to MI‐001. Device in compact or remote version.

  • Nominal diameter range

    DN 15…600
    1/2″…24″

  • Max. measurement error

    ±0.5%
    ±0.2% (optional)

  • Measuring range

    0…9’600 m3/h

  • Max. process pressure

    PN10…40

  • Medium temperature range

    -40…+150°C
    (-40…+302°F)

  • Ambient temperature range

    -20…+60°C
    -40…+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Two line display with backlit
    Push button

  • Outputs

    4…20 mA
    Pulse/Frequency
    Status

  • Inputs

    Status

  • Digital communication

    HART

  • Hazardous area approvals

    ATEX

  • Product safety

    CE, C-tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Custody transfer approvals: MI-001, PTB

Field of application
Promag P is the preferred sensor for applications with highest requirements in a multitude of industries. Combined with the proven Promag 51 transmitter with push buttons, Promag 51P offers highly accurate measurement of liquids. Promag 51P is dedicated for chemical and process applications with corrosive liquids and high medium temperatures. it will be the preferred solution for customers needing custody transfer measurement. Promag 51P is available in a compact or remote version.

The measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated for chemical and process applications with corrosive liquids and high medium temperatures.Device propertiesNominal diameter: max. DN 600 (24″)All common Ex approvalsLiner made of PTFE or PFATransmitter certified to MI-001Device in compact or remote versionHART

Benefits
Versatile applications – wide variety of wetted materialsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionQuality – designed for custody transfer; featuring worldwide recognized metrological approvalsSafe operation – display provides easy readable process informationFully industry compliant – IEC/EN/NAMURMaintenance-free – no moving parts

TW15 Barstock thermowell

Thermowell made of drilled barstock material. Mainly used in heavy duty or industrial applications

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    metric style
    DIN 43772 Form 4/4F
    flanged process connection or weld-in with neck

  • Head connection

    external thread:
    M24 x 1.5
    1/2″ NPT

  • Maximum standard immersion length

    250 mm (9,84″)

  • Max. immersion length on request

    400 mm (15,75″)

  • Process connection

    For welding with welding socket TA115 as accessory
    For flanging with the following flange sizes:
    DN25 PN40 B1
    DN40 PN40 B1
    DN50 PN40 B1
    ASME 1″ 150 RF
    ASME 1″ 300 RF
    ASME 1 1/2″ 150 RF

  • Thermowell root diameter

    18 mm (0,71″)
    24 mm (0,94″)

  • Medium contact material

    1.4571 (316Ti)
    2.4819 (Alloy C276)
    1.7335 (13CrMo4-5)
    Titan
    Duplex SAF2205
    C22.8
    1.5415 (16Mo3)
    1.7380 (10CrMo 9 10)

  • Wetted part finishing (Ra)

    < 0.8 µm (31.50 µin)
    < 1.6 µm (63.00 µin)

  • Tip shape

    conical

  • Temperature range

    -200…1.100 °C (-328…2.012 °F)

  • Max. process pressure (static)

    400 bar (5802 psi)

  • Max. process pressure at 400 °C

    400 bar (5802 psi)

Field of application
Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.

TW15 is designed for use with resistance and thermocouple thermometers in heavy duty applications.
Modular configuration according to DIN 43772 (form 4/4F) enable a use in all industrial processes with severe thermal and mechanical stresses.

Benefits
Extension, immersion length and total length can be chosen according to process requirementsA wide choice of dimensions, materials and process connections is availableSpecial versions can be manufactured according to customer requirementsThe process connection can either be weld-in or flanged

TU54 Flanged barstock thermowell, US style

Thermowell with flanged process connections and round extension

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    US-style
    flanged process connections

  • Head connection

    internal thread:
    1/2″ NPT

  • Maximum standard immersion length

    24″

  • Process connection

    flange
    ASME 1″ 150 RF (B16.5)
    ASME 1″ 300 RF (B16.5)
    ASME 1″ 600 RF (B16.5)
    ASME 1″ 900/1500 RF (B16.5)
    ASME 1.5″ 150 RF (B16.5)
    ASME 1.5″ 300 RF (B16.5)
    ASME 1.5″ 600 RF (B16.5)
    ASME 1.5″ 900/1500 RF (B16.5)
    ASME 2″ 150 RF (B16.5)
    ASME 2″ 300 RF (B16.5)
    ASME 2″ 600 RF (B16.5)
    ASME 2″ 900/1500 RF (B16.5)
    ASME 3″ 150 RF (B16.5)
    ASME 3″ 300 RF (B16.5)
    ASME 3″ 600 RF (B16.5)

  • Thermowell root diameter

    3/4”
    7/8″
    1 1/16″

  • Medium contact material

    316/ 316L
    304
    others on request

  • Wetted part finishing (Ra)

    32 µin (0.80 µin)

  • Tip shape

    straight
    tapered
    stepped

  • Temperature range

    -200…700 °C (-328…1.292 °F)

  • Max. process pressure (static)

    500 bar (7252 psi)

  • Max. process pressure at 400 °C

    depends on configuration

Field of application
The robust thermowell is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials.

Designed for use with resistance and thermocouple thermometers in industrial or heavy duty applications.

For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by replacing the insert in closed processes

Benefits
Extension, immersion length and total length can be chosen according to process requirementsModular configuration enable a use in all industrial processes with severe thermal and mechanical stressesFast response time with conical or stepped tip form

TU53 Threaded barstock thermowell, US style

Thermowell with threaded process connections and hexagonal extension

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    US-style
    threaded process connections

  • Head connection

    internal thread:
    1/2″ NPT

  • Maximum standard immersion length

    24″

  • Max. immersion length on request

    Not defined

  • Process connection

    threads:
    1/2″ NPT
    3/4″ NPT
    1″ NPT

  • Thermowell root diameter

    5/8″
    3/4″
    7/8″
    1 1/16″

  • Medium contact material

    316/ 316L
    A105
    AlloyC276
    others on request

  • Wetted part finishing (Ra)

    32 µin (0.80 µin)

  • Tip shape

    straight
    taperedl
    stepped

  • Temperature range

    -200…700 °C (-328…1.292 °F)

  • Max. process pressure (static)

    500 bar (7252 psi)

  • Max. process pressure at 400 °C

    depends on configuration

Field of application
The robust thermowell is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials.

Designed for use with resistance and thermocouple thermometers in industrial or heavy duty applications.

For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by replacing the insert in closed processes

Benefits
Extension, immersion length and total length can be chosen according to process requirementsModular configuration enable a use in all industrial processes with severe thermal and mechanical stressesFast response time with conical or stepped tip form

TU52 Socket weld barstock thermowell, US style

Thermowell with socket weld process connections and round extension

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    US-style
    weld-in process connections

  • Head connection

    internal thread:
    1/2″ NPT

  • Maximum standard immersion length

    24″

  • Process connection

    socket weld

  • Thermowell root diameter

    3/4″
    7/8″
    1″

  • Medium contact material

    316/ 316L
    others on request

  • Wetted part finishing (Ra)

    32 µin (0.80 µin)

  • Tip shape

    straight
    tappered
    stepped

  • Temperature range

    -200…700 °C (-328…1.292 °F)

  • Max. process pressure (static)

    500 bar (7252 psi)

  • Max. process pressure at 400 °C

    depends on configuration

Field of application
The robust thermowell is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials.

Designed for use with resistance and thermocouple thermometers in industrial or heavy duty applications.

For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by replacing the insert in closed processes

Benefits
Extension, immersion length and total length can be chosen according to process requirementsModular configuration enable a use in all industrial processes with severe thermal and mechanical stressesFast response time with conical or stepped tip form

TU51 Weld-in barstock thermowell, US style

Thermowell with weld-in process connections and round extension

  • Measuring principle

    Bar stock Thermowell

  • Characteristic / Application

    US-style
    weld-in process connections

  • Head connection

    internal thread:
    1/2″ NPT

  • Maximum standard immersion length

    24″

  • Process connection

    weld-in

  • Thermowell root diameter

    1.050″
    1.315″

  • Medium contact material

    316/ 316L
    others on request

  • Wetted part finishing (Ra)

    32 µin (0.80 µin)

  • Tip shape

    tapered

  • Temperature range

    -200…700 °C (-328…1.292 °F)

  • Max. process pressure (static)

    500 bar (7252 psi)

  • Max. process pressure at 400 °C

    depends on configuration

Field of application
The robust thermowell is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials.

Designed for use with resistance and thermocouple thermometers in industrial or heavy duty applications.

For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by replacing the insert in closed processes

Benefits
Extension, immersion length and total length can be chosen according to process requirementsModular configuration enable a use in all industrial processes with severe thermal and mechanical stressesFast response time with conical tip form

Thermophant T TTR35 Temperature switch

Compact and cost-saving for safe monitoring of process temperatures in hygienic applications

  • Measuring principle

    Temperature switch

  • Characteristic / Application

    Intelligent temperature switch with Pt100 sensor (class A)
    for hygenic applications
    FDA compliant

  • Auxiliary power supply

    12…30 V DC

  • Accuracy

    -50…75 °C: <0,5 K
    (-58…167 °F: <0,9 °F)
    75…150 °C: <0,65 K
    (167…302 °F: <1,2 °F)

  • Long term drift

    <0,1 K/a (<0,2°F)

  • Operating temperature range

    -50…150 °C (-58…302 °F)

  • Process connection

    hygienic connections

  • Hint

    Not defined

Field of application
Cost efficiency, optimal use of space, reliable operation and easy commissioning indicate modern process measuring technology. The temperature switch completely fulfills these requirements in the Food & Beverage as well as in the Life Science industry. Designed for safe monitoring of process temperatures it can be selected between one or two switch outputs as well as one switch output and one standardized analog output. A variety of hygienic process connections leads to a flexible use.

Temperature switch for the monitoring, display and control of process temperatures in a range from -50 to +150 °C (-58 to +302 °F), optional for TTR35 with neck: -50 to +200 °C (-58 to +392 °F) . Thermophant T TTR35 – for hygienic applications.
Electronic versions:One PNP switch outputTwo PNP switch outputs2 x PNP switch outputs or one PNP switch output and 4 to 20 mA output (active)

Benefits
Integrated switching electronics for decentral and economic process monitoring and control3A approvedFunction control and information on-site thanks to LEDs and digital displayLong-term stable temperature sensor made of platinum (Pt100 class A as per IEC 60751) High accuracy across the entire ambient temperature range and short response timeOperation and visualization also with PC and FieldCare or ReadWin 2000 configuration softwareDESINA-compliant

Thermophant T TTR31 Temperature switch

Compact and cost-saving for safe monitoring of process temperatures

  • Measuring principle

    Temperature switch

  • Characteristic / Application

    Intelligent temperature switch with Pt100 sensor (Class A)
    DESINA compliant

  • Auxiliary power supply

    12…30 V DC

  • Accuracy

    -50…75 °C: <0,5 K
    (-58…167 °F: <0,9 °F)
    75…150 °C: <0,65 K
    (167…302 °F: <1,2 °F)

  • Long term drift

    <0,1K/a (<0,2°F/a)

  • Operating temperature range

    -50…150 °C (-58…302 °F)

  • Process connection

    threads, clamp connection

  • Hint

    Not defined

Field of application
Cost efficiency, optimal use of space, reliable operation, easy installation and commissioning indicate modern process measuring technology. The temperature switch completely fulfills these requirements. Designed for the safe measurement and monitoring of process temperatures it can be selected between one or two switch outputs as well as one switch output and one standardized analog output. Vibration-proof integrated thin-film sensors guarantee highest operational safety.

Temperature switch for the monitoring, display and control of process temperatures in a range from -50 to 150 °C (-58 to 302 °F). Thermophant T TTR 31- with thread connections or coupling.
Electronic versions:One PNP switch outputTwo PNP switch outputs2 x PNP switch outputs or one PNP switch output and 4 to 20 mA output (active)

Benefits
Integrated switching electronics for decentral and economic process monitoring and controlHigh reproducibility and long-term stabilityFunction control and information on-site thanks to LEDs and digital display Long-term stable temperature sensor made of platinum (Pt100 class A as per IEC 60751) High accuracy across the entire ambient temperature range and short response time Operation and visualisation also with PC and FieldCare or ReadWin 2000 configuration softwareDESINA-compliant

TST434 Resistance thermometer

Comprehensive and common temperature measurement technology for almost all branches of industry

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    probe for ambient temperature measurement
    without neck

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Outer diameter protection tube / Insert

    20,0 mm (0,79”)

  • Material protection tube/ thermowell

    Aluminium

  • Operating temperature range

    PT 100:
    -50 °C …100 °C
    (-58 °F …212 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
The RTD thermometer is especially designed for monitoring the room temperature. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. For ambient temperature measurements indoor or outdoor.

Indoor or outdoor ambient temperature measurementMaximum measuring range:–50 to +100 °C (–58 to +212 °F)Degree of protection: IP66/68 (NEMA Type 4x encl.)

Benefits
Robust terminal heads according to DIN EN 50446 or stable plastic housings offer optimal protection from extreme ambient conditionsReliable, long term stable and accurate indoor or outdoor ambient temperature measurementSimple and fast wall mountingOptional head transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™

iTEMP TMT80 Temperature head transmitter

Transformation of the sensor signals into stable and standardized output signal for all industries

  • Measuring principle

    Head transmitter

  • Input

    1 x RTD, TC

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    8…35 V DC

  • Communication

    pc-programmable

  • Installation

    Terminal head form B

  • Accuracy

    (Pt100, -50…250 °C) <= 0,5 K
    (Pt100, -58…482 °F) <= 0,9 °F

  • Galvanic isolation

    yes

Field of application
This transmitter is configurable and supports both selected resistance sensor types and thermocouples. In order to obtain the highest measurement precision, linearization characteristics for every type of sensor are stored in the transmitter.The standardized output signal used for process measurement is a 4 to 20 mA signal. This offers fast, easy and cost-saving temperature measuring and reliable measurement values for a wide range of non-ex industry applications.

PC programmable (PCP) temperature head transmitter for converting various input signals into a scalable 4 to 20 mA analog output signal
Suitable for resistance thermometer (RTD) and thermocouple (TC)
Device configuration using PC with configuration kit and PC software ReadWin 2000

Benefits
2-wire technology, 4 to 20 mA analog outputFault signal on sensor break or short circuit,presettable to NAMUR NE 43Meets the EMC requirements as per NAMUR NE 21Galvanic isolation 500 V (input/output)Application specific measuring range setting

iTEMP TMT188 Temperature head transmitter

Transformation of the sensor signal into a stable and standardized output signal for all industries

  • Measuring principle

    Head transmitter

  • Input

    1 x TC

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    8…35 V DC (standard-version)
    8…30 V DC (Ex-version)

  • Installation

    Terminal head form B

  • Accuracy

    (Type K) <= 0,5 K
    (Type K) <= 0,9 °F

  • Galvanic isolation

    yes

  • Certification

    UL Ex IS
    UL Ex NI
    GOST Ex i
    GL marine approval
    GOST Metrology
    FM IS,NI,Class I,Div.1+2,Group ABCD
    CSA IS,NI,Class I,Div.1+2,Group ABCD
    ATEX II1G EEx ia IIC T4/T5/T6
    ATEX II3G Ex nA IIC Gc
    ATEX II3D Ex tc IIIC Dc
    ATEX II1G Ex ia IIC T6 Ga, II3D
    ATEX II3G Ex nA IIC Gc, II3D
    FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
    CSA General Purpose
    EAC Ex ia IIC T6 Ga
    GL (German Lloyd)

Field of application
The transmitter is designed for the transformation of a thermocouple (TC) sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications.

Fixed range temperature head transmitter for converting a TC input signal into a 4 to 20 mA analog output signal Input: Thermocouple (TC)

Benefits
High accuracy in complete ambient temperature rangeFailure information when sensor breaks or short circuits as per NAMUR NE 43EMC as per NAMUR NE 21, CE Ex approval: ATEX Ex ia and dust zone 22 in compliance with EN 50281-1; FM IS; CSA ISUL recognized component to UL 3111-1Marine approvalGalvanic isolation

iTEMP TMT128 DIN rail temperature transmitter

Transformation of the sensor signal into a stable and standardized output signal for all industries

  • Measuring principle

    Rail transmitter

  • Input

    1 x TC

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    12…35 V DC (standard-version)
    12…30 V DC (Ex-version)

  • Installation

    DIN-rail

  • Accuracy

    (Type K) <= 0,5 K
    (Type K) <=0,9 °F

  • Galvanic isolation

    yes

  • Certification

    UL rec. Comp
    marine approval
    GOST Metrology
    FM IS,NI,Class I,Div.1+2,Group ABCD
    CSA IS,NI,Class I,Div.1+2,Group ABCD
    ATEX II2(1)G Ex ia[ia Ga] IIC T6 Gb
    ATEX II3G Ex nA IIC Gc
    FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
    CSA General Purpose

Field of application
The transmitter is designed for the transformation of a TC sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications. Installation is realized on DIN rail according to IEC 60715 (housing width: 22.5 mm).

Fixed range temperature transmitter for converting TC input signals into a 4 to 20 mA analog output signal
Input: Thermocouple (TC)For DIN rail mounting

Benefits
High accuracy in complete ambient temperature rangeFault signal on sensor break or short circuit, NAMUR NE 43 compliantEMC as per NAMUR NE 21, CE Ex-Certification: ATEX Ex ia, FM IS, CSA IS UL recognized component to UL 3111-1Ship building approval GLGalvanic isolation

iTEMP TMT127 DIN rail temperature transmitter

Transformation of the sensor signal into a stable and standardized output signal for all industries

  • Measuring principle

    Rail transmitter

  • Input

    1 x analog RTD (Pt100)

  • Output

    1 x analog 4…20 mA

  • Auxiliary power supply

    12…35 V DC (standard-version)
    12…30 V DC (Ex-version)

  • Installation

    DIN-rail

  • Accuracy

    (Pt100, -50…200 °C) <= 0,2 K
    (Pt100, -58…392 °F) <= 0,4 °F

  • Galvanic isolation

    yes

  • Certification

    UL rec. Comp
    marine approval
    GOST Metrology
    FM IS,NI,Class I,Div.1+2,Group ABCD
    CSA IS,NI,Class I,Div.1+2,Group ABCD
    ATEX II2(1)G Ex ia[ia Ga] IIC T6 Gb
    ATEX II3G Ex nA IIC Gc
    FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
    CSA General Purpose

Field of application
The transmitter is designed for the transformation of an RTD Pt100 sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications. Installation is realized on DIN rail according to IEC 60715 (housing width: 22.5 mm).

Fixed range temperature transmitter for converting a Pt100 input signal into a scalable 4 to 20 mA analog output signalInput: Resistance thermometer (RTD) Pt100For DIN rail mounting

Benefits
High accuracy in complete ambient temperature rangeFault signal on sensor break or short circuit, NAMUR NE 43 compliantEMC as per NAMUR NE 21, CE Ex-Certification: ATEX Ex ia, FM IS, CSA IS UL recognized component to UL 3111-1Ship building approval GLGalvanic isolation

TH56 US style thermocouple sensor, with plug connection

Cost efficient thermocouple sensor designed for use in many process and laboratory applications

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    Industrial US style
    cable probe
    process connection as compression fitting

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    1/16” (1,59 mm)
    1/8” (3,18 mm)
    3/16” (4,76 mm)
    1/4” (6,35 mm)

  • Max. immersion length on request

    up to 96″ (2438 mm)
    others on request

  • Material protection tube/ thermowell

    Sensor sheath
    316
    Alloy 600

  • Optional coating

    not applicable

  • Process connection

    compression fitting:
    NPT1/8″
    NPT1/4″

  • Tip shape

    straight

  • Surface roughness Ra

    not defined

  • Operating temperature range

    Type T:
    -270 °C …370 °C
    (-454 °F …698 °F)
    Type J:
    -210 °C …720 °C
    (-346 °F …1.328 °F)
    Type E:
    -270 °C …820 °C
    (-454 °F …1.508 °F)
    Type K:
    -270 °C …1.150 °C
    (-454 °F …2.102 °F)
    Type N:
    -270 °C … 1.150 °C
    (-454 °F …2.102 °F)

  • Max. process pressure (static)

    Standard acc. to ASTM E-230
    Special acc. to ASTM E-230

  • Accuracy

    Standard acc. to ASTM E-230
    Special acc. to ASTM E-230

  • Response time

    63% rt = 0,3 s

  • Integration head transmitter

    no

Field of application
The thermocouple sensor with plug connection is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is used in many process and laboratory applications such as heat exchangers, furnaces or dryers. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables the cable probe to detect rapid temperature changes fast and accurate.

Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose applications.The sensors can be used on:Heat exchangersPower & recovery areasFurnacesDryersFlue gasCompressor stationsProcess reactors

Benefits
Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solution.Improved galvanic isolation on most devices (2 kV)One source shopping for temperature measurement solutions. Remove and install straight out of the box!All iTEMP® transmitters provide long term stability ≤ 0.05 % per year

Translate »