Measuring principle
Absolute and gauge pressure
-
Characteristic
Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire)
-
Supply voltage
4…20 mA HART
11,5…45V DC (Non Ex):
Ex ia: 11,5…30V DC
PROFIBUS PA:
9…32 V DC (Non Ex)
FOUNDATION Fieldbus:
9…32 V DC (Non Ex) -
Reference Accuracy
Standard 0.1%
Platinum 0.075% -
Long term stability
0.2% of URL/ year
0.4% of URL/ 5 years
0.5% of URL/ 10 years -
Process temperature
-40°C…+130°C
(-40°F…+266°F
+150°C for 1h
(+302°F for 1h) -
Ambient temperature
-40°C…+85°C
(-40°F…+185°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
relative/ absolute -
Smallest calibratable span
10 mbar (0.15 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
20:1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Thread:
G1/2…G2, R1/2, MNPT1/2
Flange:
DN25…DN80,
ASME 1″…4″,
JIS 10K -
Process connection hygienic
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD -
Material process membrane
Ceramic
-
Material gasket
Viton, EPDM, NBR, Kalrez
-
Fill fluid
None, dry measuring cell
-
Material housing
Die-cast aluminum,
AISI 316L -
Communication
4…20 mA
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex