Measuring principle
Capacitive
-
Characteristic / Application
Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure)
-
Interface measurement
Interfaces liquid / liquid also with emulsion layers
-
Specialities
Inactive length
Factory calibrated
short response time by change of value -
Supply / Communication
12-36V DC HART
PFM -
Accuracy
repeatablity 0,1%
-
Linearity error for conductive liquids
<0,25%
-
Ambient temperature
-50°C…+70°C
-58°F…+158°F -
Process temperature
-80°C…200°C
-112°F…392°F -
Process pressure / max. overpressure limit
Vacuum … 100 bar
(Vaccum … 1450 psi) -
Main wetted parts
Insulation material: FEP,PFA
316L -
Process connection
G 3/4, G 1, G1 1/2 /NPT 3/4″, NPT 1, NPT1 1/2″
Flange from DN25…/ASME 1″…/JIS… -
Process connection hygienic
Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal -
Sensor length
Total length: 6m (20ft)
Inactive length: max. 2m (7ft) -
Max. measurement distance
0.42 m … 10.0 m
(1.38 ft … 33 ft) -
Communication
4…20mA HART
PFM -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175 -
Hygienic approvals
EHEDG
-
Marine approval
GL/ ABS/ DNV
-
Options
Separate housing
gas-tight probe seal -
Application limits
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating
Field of application
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures – especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
Process connections: Flanges and threads
Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
Measuring range: 0.42 to 10.0m (1.38 to 33ft)
Temperature: -80 to +200°C (-112 to +392°F)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508Reliable and universal application thanks to wide range of certificates and approvals No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higherMaterial in contact with the process made of corrosion-resistant materialMenu-guided local configuration via plain text display (optional) Two-stage overvoltage protection