Capacitance Point level detection Liquicap FTI52

  • Measuring principle

    Capacitive Liquid

  • Characteristic / Application

    Capacitive Rope probe

  • Specialities

    Interface detection
    Foam detection

  • Ambient temperature

    -50 °C … +70 °C
    (-58 °F … +158 °F)
    With separate housing:
    -50 °C … +120 °C
    (-58°F … +248 °F)

  • Process temperature

    -80 °C … +200 °C
    (-112 °F … +392 °F)

  • Process pressure / max. overpressure limit

    Vacuum … 100 bar
    (Vacuum … 1450 psi)

  • Main wetted parts

    Insulation material: FEP, PFA
    316L

  • Process connection

    G 3/4 … 1 1/2
    NPT 3/4 … 1 1/2
    Flange from DN25…/ASME 1″…/JIS 10K…

  • Process connection hygienic

    Tri-Clamp ISO2852 gap free plated
    Dairy coupling
    Flush mount

  • Sensor length

    Total length of probe: max 12m (39 ft)

  • Communication

    2- wire 19-253 VAC
    3-wire
    PFM
    Relay DPDT
    DC-PNP
    8/16 mA

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Inactive length
    Active build-up compensation
    Separate housing

  • Components

    Transmitter
    PFM: FTC325, FTC625, FTC470Z, FTC471Z
    3-wire:
    FTC325

  • Application limits

    Notice the pressure and temperature derating.
    Notice for non conductive medium the DK.

Field of application
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.

For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
Process connections: Flanges, threads, special hygienic process connections
Temperature: -80 to +200°C (-112 to +392°F)
Pressure: Vacuum to +100bar (vacuum to +1,450psi)
Sensor length: 12m (39ft)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Benefits
Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a buttonReliable and safe measurement due to active build-up compensationReliable and universal application thanks to wide range of certificates and approvalsShort reaction timeMaterial in contact with the process made of corrosion-resistant and FDA-listed materialsTwo-stage overvoltage protectionNo need for recalibration after replacing electronics