Measuring principle
Capacitive Liquid
-
Characteristic / Application
Capacitive Rope probe
-
Specialities
Interface detection
Foam detection -
Ambient temperature
-50 °C … +70 °C
(-58 °F … +158 °F)
With separate housing:
-50 °C … +120 °C
(-58°F … +248 °F) -
Process temperature
-80 °C … +200 °C
(-112 °F … +392 °F) -
Process pressure / max. overpressure limit
Vacuum … 100 bar
(Vacuum … 1450 psi) -
Main wetted parts
Insulation material: FEP, PFA
316L -
Process connection
G 3/4 … 1 1/2
NPT 3/4 … 1 1/2
Flange from DN25…/ASME 1″…/JIS 10K… -
Process connection hygienic
Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount -
Sensor length
Total length of probe: max 12m (39 ft)
-
Communication
2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC
-
Safety approvals
Overfill prevention WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175 -
Marine approval
GL/ ABS/ DNV
-
Options
Inactive length
Active build-up compensation
Separate housing -
Components
Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325 -
Application limits
Notice the pressure and temperature derating.
Notice for non conductive medium the DK.
Field of application
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.
For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
Process connections: Flanges, threads, special hygienic process connections
Temperature: -80 to +200°C (-112 to +392°F)
Pressure: Vacuum to +100bar (vacuum to +1,450psi)
Sensor length: 12m (39ft)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Benefits
Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a buttonReliable and safe measurement due to active build-up compensationReliable and universal application thanks to wide range of certificates and approvalsShort reaction timeMaterial in contact with the process made of corrosion-resistant and FDA-listed materialsTwo-stage overvoltage protectionNo need for recalibration after replacing electronics