Measuring principle
Conductive
-
Characteristic / Application
One rod probe for high temperature and high pressure. corrosion resistant
-
Supply / Communication
Relay
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 135 °C
(-40 °F … 275 °F) -
Process pressure / max. overpressure limit
Vacuum … 50 bar
(Vacuum … 725 psi) -
Min. conductivity of medium
20 µS/cm
-
Main wetted parts
PTFE, 316TI
-
Process connection
G1/2
-
Sensor length
0.05m … 2m
(2″ … 79″) -
Communication
Relay
-
Certificates / Approvals
ATEX
-
Components
Transmitter: FTW325
-
Application limits
observe min. medium conductivity
Field of application
The 11375Z is a cost-effective and reliable solution for conductive point level detection in process or storage tanks for all kinds of liquids.
For conductive point level detection in process or storage tanks, for conductivity as of 0.02mS/cm. As overfill prevention with line monitoring even in Ex-area Zone 0 or as pump protection in pipes and two-point control.
Process connection: Thread
Measuring range: 50 to 2,000mm (1.9 to 78.7″)
Temperature: -40 to +200°C (-40 to 392°F)
Pressure: -1 to +50bar (-15 to +725psi )
Components: Transmitter FTW325
International explosion protection certificates, overfill prevention WHG
Benefits
Long operating life and reliable function without wear since no moving parts in the tank Cost-effective probe for conductive liquid Probe can be shortened as requiredCooling adapter for higher fluid temperatures, as of 100°C