Measuring principle
Inductive
-
Application
Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology
-
Characteristic
Specifically intended for use in hygienic applications and especially suitable for following applications:
Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring -
Measurement range
100 µS/cm to 2000 mS/cm
Cell constant k : 6.3 1/cm -
Measuring principle
Inductive conductivity measurement
-
Design
Hygienic design with FDA certified virgin PEEK body including all hygienic certifications
-
Material
In contact with medium: Virgin PEEK
-
Process temperature
Max. 125 °C (max. 257 °F)
For sterilization: up to 150 °C for max. 60 min
(up to 302 °F for max. 60 min) -
Process pressure
12 bar abs up to 90 °C
(174 psi abs up to 194 °F) -
Temperature sensor
Pt 1000
-
Connection
Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2″, Varivent N DN 40-125, Neumo Biocontrol D50
-
Ingress protection
IP67
-
Output / communication
Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus
-
Additional certifications
FDA, EHEDG, 3A
Biological reactivity USP class VI part <87> and <88>
EC Regulation No. 1935/2004
Field of application
Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.
The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants, quality assurance
Leakage monitoring
It features the following protocols and interfaces:
0/4…20mA
HART
PROFIBUS DP
PROFIBUS PA
Benefits
Unique hygienic design avoids recontaminationWith all hygienic certificates required in hygienic and sterile applicationsCertified biocompatibility according to USP class VICompliant with EG 2023/2006 and 1935/2004 Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP) Durable thanks to encapsulated, jointless design