Measuring principle
Sensor ORP / Redox
-
Application
Processapplications, heavy soiled media, emulsions, suspensions, precipitations
-
Installation
digital electrode with Memosenstechnology
-
Characteristic
Very robust, easy cleanable.
-
Measurement range
-1500 mV – +1500 mV
-
Measuring principle
– Gel compact electrode with open aperture – measuring part as platinum cap.
-
Design
All shaft lengths – advanced gel technology
-
Material
Glass electrode and platinum cap.
-
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch) -
Process temperature
max. 110°C (230°F)
-
Process pressure
max. 13bar (189psi)
-
Temperature sensor
NTC30k
-
Ex certification
ATEX II IG EEXia IIC T3/T4/T6
FM/CSA Class1 Div.2 in Kombination mit CM42 und CPM153 Messumformer. -
Connection
Memosens
-
Ingress protection
IP68
Field of application
Orbipore CPS92D is the digital specialist for fibrous media or media with a high content of suspended solids such as dispersions, precipitation reactions or emulsions. The open aperture prevents fouling and guarantees you the most reliable measurement under extreme process conditions. Orbipore CPS92D is not the latest Memosens generation. To get information on the new Memosens CPS92E sensor with extended functionality, click here.
Chemical processesPulp and paper industryContaminated media and suspended solids:- Dispersions- Precipitation- EmulsionsWith ATEX, FM, and CSA approval for application in hazardous areas.
Benefits
Open aperture for application in heavily soiled media Low maintenance and long service life due to stabilized gel filling Not affected by fluctuations in pressure and temperatureMaximum process safety through non-contact inductive signal transmissionEnables predictive maintenance due to storage of sensor and process-specific dataReduced operating costs thanks to minimized process downtime and extended sensor lifetime