Guided radar measurement Time-of-Flight Levelflex FMP50

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Basic device
    Rod probe, Rope probe
    Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe: +/- 2 mm (0.08 in)
    Rope probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process pressure / max. overpressure limit

    Vacuum…6 bar,
    (Vacuum…87 psi)

  • Main wetted parts

    Rod probe: 316L, PPS, Viton
    Rope probe: 316, PPS, Viton

  • Process connection

    Thread:
    G 3/4, MNPT 3/4
    Flange:
    UNI Flange

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 12 m (40 ft)

  • Max. measurement distance

    Rod: 4 m (13 ft) Min DK>1.6
    Rope: 12 m (40 ft) Min DK>1.6

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod or rope probe.
Process connections: Thread or adapter flange
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +87psi)
Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs