Guided radar measurement Time-of-Flight Levelflex FMP52

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device coated for corrosive media
    Rod probe, Rope probe
    Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.

  • Interface measurement

    Clean interfaces liquid/ liquid;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe :+/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft):
    +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft):
    +/- 10 mm (0.39 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -50…+200 °C
    (-58…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    Rod probe:
    304, 304L, 316L, PTFE, PFA
    Rope probe:
    304, 304L, 316, 316L, PTFE, PFA

  • Process connection

    Flange:
    ASME 1 1/2″…6″,
    DN50…DN100,
    JIS 10K

  • Process connection hygienic

    Tri-Clamp
    DIN11851

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 45 m (148 ft)

  • Max. measurement distance

    Rod:
    4 m (13 ft) Min DK>1.6
    Rope:
    25 m…30 m (82 ft…98 ft) Min DK>1.6;
    30 m…45 m (98 ft…148 ft) Min DK>1,9

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    ASME B31.1, B31.3
    AD2000

  • Hygienic approvals

    3A, EHEDG

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Gas-tight feed through,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod or rope probe.

Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Spread the love

Contact Us

    Please prove you are human by selecting the tree.