High-Temperature Thermocouple – TAF16

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    modular temperature assembly
    high temperature probe (furnace)
    incl. thermowell / protection tube (metal)

  • Thermowell / protection tube

    welded protection tube
    ceramic protection tube

  • Insert / probe

    mineral insulated (MI), flexible
    ceramic capilarry, rigid

  • Outer diameter protection tube / Insert

    14,0 mm (0,55″)
    15,0 mm (0,59″)
    17,2 mm (0,68″)
    18,0 mm (0,71″)
    21,3 mm (0,84″)
    22,0 mm (0,87″)
    26,7 mm (1,05″)
    28,0 mm (1,10″)

  • Max. immersion length on request

    up to 4.525,00 mm (178,15”)

  • Material protection tube/ thermowell

    1.4401 (316)
    1.4749 (~446)
    1.4841 (310)
    Alloy 600 (2.4816)
    Alloy 601 (2.4851)
    Incoloy 800HT (1.4959)
    Kanthal AF
    Kanthal Super
    NiCo
    Siliciumnitrid(SiN)

  • Process connection

    compression fitting:
    G1/2″
    G3/4″
    G1″
    G11/4″
    G11/2″
    adjustable Flange

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    -40 °C …1.100 °C
    (-40 °F …2.012 °F)
    Type J:
    -40 °C …750 °C
    (-40 °F …1.382 °F)
    Type N:
    -40 °C …1.150 °C
    (-40 °F …2102 °F)
    Type S:
    0 °C …1.400 °C
    (32 °F …2.552 °F)

  • Max. process pressure (static)

    at 20 °C: 1 bar (15 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    SIL (transmitter only)

Field of application
Measuring points with extremely high process temperatures require this high-temperature thermometer with a ceramic or metal thermowell as well as thermocouples made from special metals such as platinum and rhodium. The thermowell made from special materials protects from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

Applicable for temperature measurement in cement production, steel treatment, incinerators and fluidized bed furnaces. The TAF16 contains a single or double thermocouple insert and a metal or ceramic protection tube as well as an optional internal sheathProcess temperatures: up to +1,700 °C (+3,092 °F)

Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong-term stable measurement due to sensor protection with non-porous materialsFlexible product selection thanks to modular designOptimized life cycle costs by means of replaceable spare parts

Spread the love

Contact Us