Measuring principle
Colorimetric
-
Characteristic
Process analyzer for iron in aqueous solutions
Comply with standard colorimetric measuring principle, ferrozine method -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Application
Monitoring of the iron content of potable water, mineral water and source water for industrial processes
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Webserver, Modbus, Ethernet/IP, Profibus DP -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe -
Consumables
Reagents and standard solutions CY80FE for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
Field of application
Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.
Liquiline System CA80FE monitors:Iron content in drinking water and mineral waterResidual iron after precipitation, flocculation and filtration processesProcess water containing diluted iron
Benefits
Compliance with standard ferrozine method ensures direct comparability to lab measurements Supports predictive maintenance by advanced diagnostics Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors. Comfortable remote access via integrated web server Seamless integration into process control systems thanks to digital field busses such as Modbus, PROFIBUS or EtherNet/IP