Measuring principle
Head transmitter
-
Input
1 x TC
-
Output
1 x analog 4…20 mA
-
Auxiliary power supply
8…35 V DC (standard-version)
8…30 V DC (Ex-version) -
Installation
Terminal head form B
-
Accuracy
(Type K) <= 0,5 K
(Type K) <= 0,9 °F -
Galvanic isolation
yes
-
Certification
UL Ex IS
UL Ex NI
GOST Ex i
GL marine approval
GOST Metrology
FM IS,NI,Class I,Div.1+2,Group ABCD
CSA IS,NI,Class I,Div.1+2,Group ABCD
ATEX II1G EEx ia IIC T4/T5/T6
ATEX II3G Ex nA IIC Gc
ATEX II3D Ex tc IIIC Dc
ATEX II1G Ex ia IIC T6 Ga, II3D
ATEX II3G Ex nA IIC Gc, II3D
FM+CSA IS,NI,Class I,Div.1+2,Group ABCD
CSA General Purpose
EAC Ex ia IIC T6 Ga
GL (German Lloyd)
Field of application
The transmitter is designed for the transformation of a thermocouple (TC) sensor signal in a fixed measuring range. The standardized output signal used for process measurement is a 4 to 20 mA signal. This means fast, easy and cost-saving temperature measuring as well as reliable and precise measured values for for a wide range of industry applications.
Fixed range temperature head transmitter for converting a TC input signal into a 4 to 20 mA analog output signal Input: Thermocouple (TC)
Benefits
High accuracy in complete ambient temperature rangeFailure information when sensor breaks or short circuits as per NAMUR NE 43EMC as per NAMUR NE 21, CE Ex approval: ATEX Ex ia and dust zone 22 in compliance with EN 50281-1; FM IS; CSA ISUL recognized component to UL 3111-1Marine approvalGalvanic isolation