iTEMP TMT84 Temperature head transmitter

  • Measuring principle

    Head transmitter

  • Input

    2 x RTD, TC, Ohm, mV

  • Output

    PROFIBUS PA

  • Auxiliary power supply

    9…32 V DC (PROFIBUS PA)
    9…17,5 V DC (FISCO/FNICO)

  • Communication

    PROFIBUS PA

  • Installation

    Terminal head form B

  • Accuracy

    (Pt100) <= 0,1 K
    (Pt100) <= 0,18 °F

  • Galvanic isolation

    yes

  • Certification

    ATEX II3G Ex ic IIC T6 Gc
    ATEX II2D Ex tb IIIC Db
    ATEX II1G Ex ia IIC T4/T5/T6
    ATEX II3G Ex nA IIC T6 Gc
    ATEX II3D Ex tc IIIC Dc
    ATEX II1G Ex ia IIC T6 Ga, II3D
    ATEX II3G Ex nA IIC T6 Gc, II3D
    ATEX II2G Ex d T6, II2D Ex tb IIIC
    FM+CSA IS, NI I/1+2/ABCD
    CSA C/US General Purpose
    FM IS, NI I/1+2/ABCD
    CSA IS, NI I/1+2/ABCD
    CSA XP, NI, DIP I, II, III/1+2/A-G
    NEPSI Ex ia IIC T4/T5/T6
    TIIS Ex ia IIC T6
    NEPSI Ex nA IIC T4/T5/T6
    IECEx Ex ia IIC T4/T5/T6
    FM XP, NI, DIP I, II, III/1+2/A-G
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    IECEx Ex tb IIIC Db
    IECEx Ex d T6 Gb, Ex tb IIIC Db
    INMETRO Ex ia [ia Ga] IIC T6 Gb
    INMETRO Ex d T6 Gb, Ex tb IIIC Db
    NEPSI Ex d IIC T6 Gb
    UK II2D Ex tb IIIC Db
    UK II3D Ex tc IIIC Dc
    UK II1G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
    UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
    UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    ATEX IECEx II1G Ex ia IIC T6 Ga

Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.

2 input channels and PROFIBUS® PA protocol for the conversion of input signals into digital output signals The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes) For the highest level of safety, availability and risk reductionInstallation in flat-face terminal head as per DIN EN 50446Optional installation in field housings even for use in Ex d areas – with mounting brackets for wall or pipe mounting

Benefits
Easy and standardized communication via PROFIBUS® PA Profile 3.02Meets the EMC requirements as per NAMUR NE 21 and the recommendations of NE 89 with regard to temperature transmitters with digital signal processingStraightforward design of measuring points in Ex-areas through FISCO/FNICO conformity in accordance with IEC 600079-27 Safe operation in hazardous areas thanks to international approvals such as FM IS, NI, CSA IS, NI as well as ATEX Ex ia, Ex nA (Ex nL)High accuracy through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognition Rapid no-tools wiring due to optional spring terminal technology