iTEMP TMT86 head transmitter with Ethernet-APL

  • Measuring principle

    Head transmitter

  • Input

    2 x RTD, TC, Ohm, mV

  • Output

    PROFINET

  • Auxiliary power supply

    9,6…15 V DC (Ethernet-APL)
    20…30 V DC (SPE)

  • Communication

    PROFINET with Ethernet-APL

  • Installation

    Terminal head form B / in field

  • Accuracy

    (Pt100, -50…200 °C) <= 0,1 K
    (Pt100, -58…392 °F) <= 0,18 °F

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T6
    ATEX II3G Ex ic IIC T6 Gc
    ATEX II3D Ex tc IIIC Dc
    ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc
    ATEX II3G Ex ec IIC T6, II3D
    ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
    CSA C/US General Purpose
    CSA C/US IS I/1/A-D, AEx/Ex ia IIC, NI I/2/A-D, AEx/Ex ec IIC Gc
    CSA XP, NI, DIP I, II, III/1+2/A-G
    EAC Ex ia IIC T6 Ga
    EAC Ex d IIC T6 Gb
    IECEx Ex d T6 Gb, Ex tb IIIC Db
    KC Ex ia IIC T6 Ga
    KC Ex db IIC T6 Gb
    INMETRO Ex ia IIC T6 Ga
    INMETRO Ex d T6 Gb, Ex tb IIIC Db
    NEPSI Ex ia IIC T4/T5/T6
    NEPSI Ex d IIC T6 Gb
    UK Ex ia IIC T6 Ga
    UK Ex d IIC T6 Gb
    ATEX IECEx II1G Ex ia IIC T6 Ga
    ATEX IECEx II2D Ex tb IIIC Db

Field of application
The iTEMP TMT86 is a reliable, intelligent and future proof dual-channel Ethernet-APL PROFINET temperature head transmitter for thermometers with terminal head form B and is suitable for use in hazardous areas. ​Beneficial diagnostic functions like corrosion monitoring of the sensor wires help to improve the plant up-time. The embedded webserver and the up-to-date FDI package simplifies the device configuration and integration.

Ethernet-APL: 2-wire Ethernet IEEE 802.3cg 10BASE-T1LTemperature measurement with two independent universal inputs (RTD, Ω, TC, mV)System integration with PROFINET®Installation in terminal head form B (flat face) as per DIN EN 50446Optional: installation in field housing for Ex d applicationsReliability, long-term stability, high precision and advanced diagnostic function in critical processes

Benefits
Digital communication down to the field level, even in explosive atmospheresEasy and standardized system integration via PROFINET® Profile 4Integrated web server offers simplicity during commissioning and maintenanceHigh accuracy of measuring point through sensor-transmitter matchingReliable operation with sensor monitoring and device hardware fault recognitionFast and tool-free wiring thanks to push-in terminal technology, optionalAttachable measured value display, optional

Spread the love