Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
universal range of application
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube or to be used with thermowell
-
Insert / probe
Basis Sensortechnologie
-
Outer diameter protection tube / Insert
Thermowell:
9×1,25 mm
11×2 mm -
Max. immersion length on request
up to 1.000,0 mm (39”)
-
Material protection tube/ thermowell
316L (1.4404)
-
Process connection
Thread:
G1/2″
NPT1/2″
M20x1.5, M27x2, M33x2
Compression fitting:
NPT1/2″, G1/2″, G1″
Flansche:
DN25 DN40 B1
ASME 1″ 150 RF
ASME 1″ 300 RF
ASME 1 1/2″ 150 RF
ASME 2″ 150 RF
ASME 2″ 300 RF -
Tip shape
straight
-
Operating temperature range
Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration
-
Accuracy
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2 -
Response time
t90 around 100 s
depending on configuration -
Integration head transmitter
yes (4 … 20 mA; HART)
Field of application
RTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
Universal range of applicationApplication in non-hazardous areasMeasuring range: –50 to +650 °C (–58 to +1202 °F)Pressure range up to 50 bar (725 psi)Degree of protection: up to IP 68
Benefits
Economical, reliable measurementUser-friendly from product selection to maintenance Wide range of process connectionsEasy and safe device setup and service using Bluetooth® communication