Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with StrongSens -
Thermowell / protection tube
barstock (drilled) or to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
16 mm (0,63″)
18 mm (0,71″)
19 mm (0,75″)
19,5 mm (0,77″)
20 mm (0,79″)
22,2 mm (0,87″)
24 mm (0,95″)
25 mm (0,98″)
25,4 mm (1,0″)
26 mm (1,02″)
27 mm (1,06″)
30 mm (1,18″)
33,4 mm (1,31″) -
Max. immersion length on request
up to 1.500,0 mm (59,06”)
-
Material protection tube/ thermowell
316 (1.4401)
316L (1.4404)
316/316L (1.4401/1.4404)
316Ti (1.4571)
347 (1.4550)
310 (1.4841)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
10CrMo9-10 (1.7380)
13CrMo4-5 (1.7335)
16Mo3 (1.5415)
A105 (1.0460)
C22.8 (P250GH) (1.0460)
P355NH (1.0565)
Duplex S32205 (1.4462)
Titanium Gr2 (3.7035) -
Process connection
Male thread:
G1″
NPT1/2″, NPT3/4″, NPT 1″
M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
Female thread:
M24x1.5
NPT1/2″
Flange:
DN25 PN16, PN40, PN50, PN100 B1
DN40 PN40 B1
DN50 PN40, PN63 B1
ASME 1″ 150 RF
ASME 1″ 300 RF
ASME 1″ 600 RF
ASME 1″ 900/1500 RF
ASME 1 1/2″ 150 RF
ASME 1 1/2″ 300 RF
ASME 1 1/2″ 600 RF
ASME 1 1/2″ 900/1500 RF
ASME 1 1/2″ 2500 RF
ASME 2″ 150 RF
ASME 2″ 300 RF
ASME 2″ 600 RF
ASME 2″ 900/1500 RF
ASME 2″ 2500 RF
to weld-in:
Diameter 18 mm (0,71″)
Diameter 24 mm (0,94″)
Diameter 26 mm (1,02″)
Diameter 26,7 mm (NPS 3/4″)
Diameter 33,4 mm (NPS 1″) -
Tip shape
straight
tapered
stepped -
Surface roughness Ra
0,76 μm (30 μin.)
1,6 μm (63,0 μin.) -
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration up to 500 bar
-
Accuracy
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II3G Ex ec IIC T6, II3D
CSA C/US General Purpose
CSA C/US IS, NI I/1+2/A-D
CSA C/US XP, NI, DIP I, II, III/1+2/A-G
CSA C/US DIP II, III / 1/E-G
EAC 0Ex ia IIC T6…T1 Ga X
EAC Ga/Gb Ex d IIC T6…T1 X
EAC Ex ta/tb IIIC 85oC…450oC Da/Db X
EAC Ga/Gb Ex ia IIC T6…T1 X
EAC 0Ex ia IIC T6…T1 Ga X, Ex ia IIIC 85oC…450oC Da/Db X
EAC Ga/Gb Ex d IIC T6…T1 X, Ex ta/tb IIIC 85oC…450oC Da/Db X
INMETRO Ex ia IIC T6 Ga/Gb, Ex ia IIIC Da/Db
INMETRO Ex d IIC T6 Ga/Gb, Ex tb IIIC Da/Db
INMETRO Ex nA IIC T6 Gc
CCC Ex ia II