Measuring principle
Microwave barrier
-
Characteristic / Application
Transceiver
Non-contact point level detection and flow monitoring
Detecting, counting and positioning of objects
Monitoring of material transfer points
Detection and analysis of deposits and contamination
Installation:
Non-contact installation (transmission window) or front-flush installation (contact) -
Specialities
Measuement range: max. 100 m
-
Supply / Communication
85 … 253 VAC
20 … 60 VDC/ 20 … 30 VAC -
Ambient temperature
-40 °C…+70 °C
(-40°F…+158°F) -
Process temperature
Non-contact installation: any
Within installation:
-40 °C…+70 °C (-40 °F…+158 °F)
With HT-Adapter:
up to +450 °C (+842 °F) -
Process pressure / max. overpressure limit
Non-contact installation: any
Within installation:
0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.
With HD-Adapter:
up to +21 bar (+305 psi) abs. -
Min. density of medium
Solid weight: > 10 g/l
-
Main wetted parts
Non-contact installation:
no wetted parts
Within installation:
316Ti or Aluminium;
PTFE or Ceramic -
Process connection
1-1/2″ R, 1-1/2″ G, 1-1/2″ NPT
-
Process connection hygienic
Non-contact installation
-
Communication
Relays SPDT
Solid-State-Relaiy
4 … 20 mA -
Certificates / Approvals
ATEX, CSA C/US, IEC Ex
-
Design approvals
EN10204-3.1
-
Options
Sight glass
High temperature adapter
High pressure adapter
Installation bracket
FAR50, FAR51, FAR52, FAR53, FAR54, FAR55 -
Components
Transmitter: FQR56
-
Application limits
Solid weight: < 10 g/l
Field of application
The Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.
Typical bulk solids are: Wood chips, wood dust or flour; plaster, cement, ash; paper or cardboard shred, gravel, sand, dried powders in general, bags and boxes.Process connections: ThreadsAmbient temperature: -40 to +70°C (-40 to +158°F)Measuring range: Max. 100m (328ft)International explosion protection certificates
Benefits
Highly reliable measurement due to flush-mounted installation and possible non-contact installation as well as indication of the signal strength on the transceiverMechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free Electronics housing can be rotated by 360°, allowing adjustment into optimum position after installationDirect connection of the supply voltage (emitter and receiver separately or together)Mechanically compatible to FQR50/FDR50 microwave barrier, existing process connections can continue to be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can continue to be used