Microwave flow indicator Solimotion FTR20

  • Measuring principle

    Microwave barrier

  • Characteristic / Application

    Flow indicator for bulk solids
    Non-contact motion detection (movement / no movement)
    of pneumatically or mechanically conveyed bulk solids of all kinds,
    also in potentially explosive atmospheres (dust Ex)
    Detection of changes in the mass flow of bulk solids
    via the optional 4 – 20 mA current output

  • Ambient temperature

    -40°C … +70°C
    (-40°F…158°F)

  • Process temperature

    Standard
    -40°C … +70°C
    (-40°F …158°F)
    With adapter for temperature reduction:
    -40°C to +450°C
    -40°F …+842°F)

  • Process pressure / max. overpressure limit

    0.5 … 6.8 bar abs standard
    (7.2 … 98.6 psi abs)
    When using the adapter for temperature reduction:
    0.8 to 5.1 bar abs
    (11.6 …74 psi abs)

  • Main wetted parts

    316Ti/1.4571
    Sensor diaphragm: PTFE or ceramic

  • Process connection

    Thread R 1½ (EN 10226)
    NPT 1½ (ASME B1.20.1)

  • Communication

    Relay SPDT
    Analog 4 – 20 mA
    Solid-state relay

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex

  • Design approvals

    EN10204-3.1

  • Options

    Adapter for temperature reduction

Field of application
The Solimotion FTR20 flow indicator for bulk solids is a non-contact device based on microwave technology. It is ideally suited for cost-effective monitoring of a mass flow (present or not present). The compact device can be used wherever the cost-effective monitoring of bulk solids movement is required. Individual adjustments to the application can be carried out by means of configurable functions (incl. automatic calibration).

Building materials industry: Cement, plaster, wood chips etc.Chemicals: Fertilizers, plastic powder and granules, silica etc.Food industry: Coffee, tea, tobacco, cereals, animal feeds etc.Energy production: Coal, carbon dust, fly-ash, coke etc.
Process connections: Threads or a suitable mounting bracket
Temperature: -40 to +450°C (-40 to +842°F), with adapter for temperature reduction
Pressure: 0.5 to 6.8bar abs standard (7.2 to 98.6psi abs)
International explosion protection certificates

Benefits
Sensor, transmitter and power unit mounted in one housing, which means less effort for installation and mountingHigh safety level compliant with international explosion protection certificatesFlush-mounted installation, non-contact installation possible for ideal integration into the processElectronics housing can be rotated by 360° allowing adjustment into optimum position after installationHigh cost-effectiveness thanks to its mechanical robustness: No wear, process-wetted ceramic sensor diaphragm (optional), long service life, maintenance-freeSignaling of mass flow (present or not present)

Spread the love

Contact Us

    Please prove you are human by selecting the cup.