Proline Prosonic Flow B 200 ultrasonic flowmeter

  • Measuring principle

    Ultrasonic flow

  • Product headline

    The device for accurate, reliable biogas measurement with loop-powered technology.
    Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions.

  • Sensor features

    Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
    Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a).

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals.

  • Nominal diameter range

    Single‐path version: DN 50 (2″), DN 80 (3″)
    Two‐path version: DN 100 to 200 (4 to 8″)

  • Wetted materials

    Sensor: 1.4404/1.4435 (316L)
    Transducer: HNBR
    Temperature sensor (option): AFM 34

  • Measured variables

    Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature

  • Max. measurement error

    Volume flow (standard):
    ‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
    ‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
    Volume flow (option):
    ‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
    ‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)

  • Measuring range

    Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
    Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)

  • Max. process pressure

    11 bar a (159 psi a)

  • Medium temperature range

    0 to +80 °C (+32 to +176 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Transmitter housing material

    AlSi10Mg, coated; 1.4404 (316L)

  • Degree of protection

    IP66/67, type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control
    (operation from outside)
    Configuration via local display and operating tools possible

  • Outputs

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Inputs

    Current input 4‐20 mA (passive)

  • Digital communication

    HART

  • Power supply

    DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
    DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
    DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
    DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED

  • Material certificates

    3.1 material (wetted parts)

Field of application
Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology enables compliance and process safety at all times.

The measuring principle is unaffected by gas compositionInline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.Device properties:Multivariable device: flow, temperature and methaneMedium temperature: 0 to 80 °C (32 to 176 °F)Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a)Loop-powered technologyRobust dual-compartment housingPlant safety: worldwide approvals

Benefits
Integrated real-time methane fraction measurementOptimized for low pressure gas – specialized sensor designNo additional pressure loss – full bore designProcess transparency – diagnostic capabilityConvenient device wiring – separate connection compartmentSafe operation – no need to open the device due to display with touch control, background lighting Integrated verification – Heartbeat Technology

Spread the love

Contact Us

    Please prove you are human by selecting the house.