Proline Prosonic Flow E 100 ultrasonic flowmeter

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Economical Ultrasonic flowmeter with integrated temperature measurement.
    Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines.

  • Sensor features

    Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1).
    Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel.

  • Transmitter features

    Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations.
    4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing.

  • Nominal diameter range

    DN 50 to 150 (2″to 6″)

  • Wetted materials

    Measuring tube: 1.4301 (F304)
    Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

  • Measured variables

    Volume flow, calculated mass flow, flow velocity, sound velocity, temperature

  • Max. measurement error

    Volume flow:
    – ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
    – ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)

  • Measuring range

    0.025 to 5 m/s (0.02 to 16.4 ft/s)
    0 to 6360 dm3/min (0 to 1680 gal/min)

  • Max. process pressure

    PN 25 / ASME Cl. 150

  • Medium temperature range

    0 to 150° (17.8 to 302 °F)

  • Ambient temperature range

    -20 to 60 °C (-4 to 140 °F)

  • Sensor housing material

    Stainless steel

  • Transmitter housing material

    Compact:
    AlSi10Mg, coated
    Stainless steel, 1.4301

  • Degree of protection

    Standard: IP66/67, Type 4X enclosure
    With opened housing: IP20, Type 1 enclosure

  • Display/Operation

    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Power supply

    DC 19.2 to 28.8 V

  • Hazardous area approvals

    None

  • Product safety

    CE, C-Tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
    Calibration according to EN 1434 Class 2

  • Pressure approvals and certificates

    PED

  • Material certificates

    3.1 material

Field of application
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

The measuring principle is independent of pressure, density, temperature and conductivityBidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return linesDevice properties:Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)Process temperatures up to 150 °C (302 °F)Entire meter housing made of stainless steel4-20 mA HART, pulse/frequency outputLocal display for reading and monitoring availableRobust transmitter housing

Benefits
Long-term stability – reliable, robust sensorReducing further measuring point – multivariable deviceDependable flow measurement – high turndown (200:1)Time-saving local operation without additional software and hardware – integrated web serverExtended calibration intervals – integrated device verification due to Heartbeat TechnologyEasy commissioning – brief parameter explanations

Spread the love

Contact Us

    Please prove you are human by selecting the house.