Radar measurement Micropilot FMR540

  • Measuring principle

    Level radar

  • Characteristic / Application

    Horn antenna:
    High precision measurement for for storage tanks up to 20 m (65ft)
    Parabolic antenna:
    High precision measurement for free space applications up to 40 m (131 ft)

  • Supply / Communication

    4-wire (HART)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 1 mm

  • Ambient temperature

    Standard:
    -40°C…80°C
    (-40°F…176°F)
    For calibration to regulatory standards:
    -25°C…60°C
    (-13°F…131°F)

  • Process temperature

    -40°C…200°C
    (-40°F…392°F)

  • Process pressure / max. overpressure limit

    Horn: Vacuum…16 bar (232 psi)
    Parabolic: Vacuum…6 bar (87 psi)
    Use of UNIflange: Vacuum…1 bar (14.5 psi)

  • Main wetted parts

    316L

  • Process connection

    Horn Antenna: DN100, DN150 Flange
    UNIFlange DN150, DN200, DN250
    Parabolic antenna: UNIflange with Top Target
    positioner DN200, DN250
    For dk value < 1.9, contact Endress+Hauser

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, NEPSI

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application
    Strong condensate or build-up formation
    FMR53x
    Existing stilling wells with non-ideal measuring conditions
    FMR532

Field of application
Micropilot FMR540 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. FMR540 with parabolic antenna is particularly suited for free space applications up to 40m and with horn antenna for free space applications that disallow the use of a parabolic antenna due to tank/nozzle geometry. Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.

Parabolic antenna suited for free space applications up to 40m offers high beam focusing for applications with nozzle situated close to tank wall, 4″/DN100 horn antenna suited for free space applications.
Process connection: Flange
Temperature: -40 to +200°C (-40 to +392°F)
Pressure: Vacuum to +16bar (Vacuum to +232psi)
Maximum measuring range: 40m (131ft)
Accuracy: Better than ±1mm
K-band: 26GHz
International explosion protection and custody transfer certificates, overfill prevention WHG, SIL

Benefits
Better than 1mm accuracyNational approvals (NMi, PTB) for custody transferApplicable as stand-alone system or integrated into tank gauging systems via the Tank Side Monitor NRF590Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supplyAlignment device to compensate any flange inclinationEasy on-site operation via menu-driven alphanumeric displayEasy commissioning, documentation and diagnostics via operating software (FieldCare)