Radar measurement Micropilot NMR84

  • Measuring principle

    Level radar

  • Characteristic / Application

    Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30 m (98ft)

  • Specialities

    Custody transfer level measurement

  • Supply / Communication

    85-264VAC
    52-74VAC
    19-64VDC

  • Accuracy

    up to 0.5 mm

  • Ambient temperature

    Standard:
    -40°C…60°C
    (-40°F…140°F)
    For calibration to regulatory
    standards:
    -25°C…55°C
    (-13°F…131°F)

  • Process temperature

    -40°C…150°C
    (-40°F…302°F)

  • Process pressure / max. overpressure limit

    Vacuum … 25 bar abs

  • Main wetted parts

    316L, PTFE

  • Process connection

    Flange:
    DN100/4″…DN300/12″
    UNI-Flange:
    DN150/6″…DN300/12″

  • Max. measurement distance

    40 m (131 ft)
    For calibration to regulatory standards:
    30 m (98 ft)

  • Communication

    Outputs:
    Fieldbus: Modbus RS485, V1, WM550
    HART, BPM and TRL/2 (via GE option)
    Analog 4-20mA output (Exi/ Exd)
    Relay output (Exd)
    Inputs:
    Analog 4-20mA input (Exi/ Exd)
    2-, 3-, 4-wire RTD input
    Discrete input (Exd, passive/ active)

  • Certificates / Approvals

    ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
    INMETRO, NEPSI, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    AD2000

  • Metrological approvals and certificates

    OIML, NMi, PTB

  • Options

    Redundant fieldbus
    Alu-coated or 316L housing
    Weather protection cover

  • Application limits

    Maximum measuring range is
    dependent on the tank form and/
    or application
    Strong condensate or build-up
    formation

Field of application
Micropilot NMR84 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The NMR84 free space radar with drip-off planar antenna is specifically suited for stilling well applications. The superior drip-off antenna design with proven track record eliminates problems caused by condensation.

With planar antenna particularly suited for stilling well applications.
Process connections: Flanges
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: Vacuum to +25bar (Vacuum to +362psi)
Maximum measuring range: 40m (131ft)
Accuracy: ±0.5mm (±0.02″)
Transmitting frequency: 6GHz
International explosion protection and custody transfer certificates, overfill prevention WHG, SIL

Benefits
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety Maximum reliability through accuracy up to ±0.5mm (±0.02″) Developed according to international metrology recommendations such as OIML R85 and API MPMS Local and country-specific certifications like NMi or PTB for custody transfer applications Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols Unique drip-off antenna design eliminates measurement error due to condensation build-up

Spread the love

Contact Us

    Please prove you are human by selecting the car.