Radar measurement Time-of-Flight Micropilot FMR53

  • Measuring principle

    Level radar

  • Characteristic / Application

    For common non-contact continuous level measurement in liquids,
    especially suited for small process connections and for chemically aggressive media;
    Rod antenna with PTFE coating

  • Specialities

    Heartbeat Technology,
    SIL 2 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    C-band (~6 GHz)

  • Accuracy

    +/- 6 mm (0.24 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+150 °C
    (-40…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    PTFE, PVDF

  • Process connection

    Thread:
    MNPT 1 1/2, R 1 1/2
    Flange:
    DN50…DN150,
    ASME 2″…6″,
    JIS 10K

  • Max. measurement distance

    Standard: 20 m (66 ft)

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    ASME B31.3
    AD2000

  • Options

    Display,
    Remote operation via SmartBlue App using Bluetooth®,
    Customized parameterization,
    Gas-tight feed through,
    PWIS free

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application
    Nozzle height >250 mm:
    FMR51, FMR52, FMR54
    Low DK:
    FMR51, FMR52, FMR54

Field of application
Micropilot FMR53 for simple level measurement applications in liquids. With its slim rod antenna, FMR53 free space radar is particularly suited for small process connections. The PTFE coating of the rod antenna and flange plating guarantee resistance also in aggressive media. The Micropilot FMR53 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Especially suited for small process connections, PTFE sensors usable in chemically aggressive media.
Process connections: Thread or flange
Temperature: -40 to +150°C (–40 to +302°F)
Pressure range: -1 to +40bar (–14.5 to +580psi)
Maximum measuring range: 20m (66ft)
Accuracy: ±6mm
C-band: 6GHz
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Benefits
Reliable non-contact measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test concept for SIL and WHG saves time and cost

Spread the love

Contact Us

    Please prove you are human by selecting the tree.