Radiometric level and density measurement Gammapilot FMG50

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Compact transmitter for extreme process conditions (temperature, pressure);
    Non-contact measuring technique

  • Interface measurement

    Interfaces liquid / liquid also with emulsion layers
    Interfaces liquid / solid

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning, operation and maintenance with the SmartBlue App

  • Supply / Communication

    2-wire loop powered

  • Accuracy

    +/-1%

  • Ambient temperature

    -40 °C…+80 °C,
    (-40 °F…+176 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Sensor length

    PVT scintillator
    400 mm…3000 mm,
    >3000 mm cascade mode

  • Max. measurement distance

    Unlimited measuring range,
    Cascade

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

  • Safety approvals

    Overfill protection WHG
    SIL 2/3

  • Design approvals

    EN 10204-3.1

  • Options

    Display

  • Components

    Isotope: FSG60, FSG61,
    Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
    Mounting accessories: FHG61

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Compact transmitter for extreme process conditions (temperature, pressure);
    Non-contact measuring technique

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning, operation and maintenance with the SmartBlue App

  • Supply / Communication

    2-wire loop powered

  • Accuracy

    +/-1%

  • Ambient temperature

    -40 °C…+80 °C,
    (-40 °F…+176 °F)

  • P

Spread the love