Radiometric measurement Synchronizer FHG66

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Synchronization of an unlimited number of Gamma Modulators FHG65

  • Specialities

    If multiple Gamma Modulators FHG65 are used

  • Supply / Communication

    DC: 18…36 V

  • Ambient temperature

    Mounted individually:
    -20°C …60°C
    ( -4°F … 142°F)
    Mounted in a row without lateral spacing:
    -20°C… 50°C
    ( -4°F …122°F)
    Installed in protective housing:
    -20°C … 40°C
    ( -4°F … 104°F)

  • Communication

    Relay: 1x SPDT

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Synchronization of an unlimited number of Gamma Modulators FHG65

  • Specialities

    If multiple Gamma Modulators FHG65 are used

  • Supply / Communication

    DC: 18…36 V

  • Ambient temperature

    Mounted individually:
    -20°C …60°C
    ( -4°F … 142°F)
    Mounted in a row without lateral spacing:
    -20°C… 50°C
    ( -4°F …122°F)
    Installed in protective housing:
    -20°C … 40°C
    ( -4°F … 104°F)

  • Communication

    Relay: 1x SPDT

  • Measuring principle

    Radiometric Limit

  • Communication

    Relay: 1x SPDT

  • Measuring principle

    Radiometric Limit

  • Communication

    Relay: 1x SPDT

  • Measuring principle

    Radiometric Density

  • Characteristic / Application

    Synchronization of an unlimited number of Gamma Modulators FHG65

  • Supply / Communication

    DC: 18…36 V

  • Ambient temperature

    Mounted individually:
    -20°C …60°C
    ( -4°F … 142°F)
    Mounted in a row without lateral spacing:
    -20°C… 50°C
    ( -4°F …122°F)
    Installed in protective housing:
    -20°C … 40°C
    ( -4°F … 104°F)

  • Options

    Relay: 1x SPDT

  • Specialities

    If multiple Gamma Modulators FHG65 are used

Field of application
The Gamma Synchronizer FHG66 is made for synchronization of an unlimited number of Gamma Modulators FHG65 for unhindered measurement with Gammapilot FMG60. The Gamma Modulator FHG65 is made for effective suppression of background and extraneous radiation (e. g. from non-destructive materials testing). The FHG66 observes the correct operation of just one single modulator.

Synchronization of an unlimited number of Gamma Modulators FHG65
Observation of single modulators

Benefits
Unhindered measurement with Gammapilot FMG60 in the event of interference radiation from non-destructive material testing up to 50μSv/h or fluctuating background radiationHighest system safety thanks to safe measuring signalsContinuing measurements which increase plant availability and reliabilityCost efficient system without maintenance requirementsEasy installation in conjunction with FQG61/62 source containersEasy integration into existing systems and fast operation

Spread the love

Contact Us

    Please prove you are human by selecting the car.