-
Measuring principle
Raman spectroscopy
-
Spectral coverage
Base Model and Enclosure configuration:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm) -
Spectral resolution
Base model and Enclosure configuration (average):
5 cm-1 (532 nm)
4 cm-1 (785 nm)
5 cm-1 (1000 nm)
Hybrid:
4 cm-1 (785 nm) average -
Channels
Base model and Enclosure configuration:
Up to four channels
Hybrid:
Up to two channels -
Temperature
Base model:
Operating:
5 to 35 °C / 41 to 95 °F (532 nm, 785 nm)
5 to 30 °C / 41 to 86 °F (1000 nm)
Storage:
-15 to 50 °C / 5 to 122 °F
Hybrid:
Operating: 5 to 35 °C / 41 to 95 °F
Storage: -15 to 50 °C / 5 to 122 °F
Enclosure configuration:
Operating: (all wavelengths)
5 to 50 °C / 41 to 122 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
20 to 80 %, non-condensing
-
Input voltage
Base model and Hybrid:
100-240 V, 50-60 Hz, ±10%
Enclosure configuration:
120 V ±10%, 60 Hz -OR-
230 V ±10%, 50/60 Hz -
Power consumption (W)
Base model and Hybrid:
400 (max)
250 (typical start-up)
120 (typical running)
Enclosure configuration:
1560 (max)
1560 (typical start-up)
750 (typical running) -
Warm up time (minutes)
Base model and Hybrid:
120
Enclosure configuration:
240 -
Unit dimensions (width x height x depth)
Base model and Hybrid:
483 x 267 x 556 mm
19.02 x 10.52 x 21.89 inch
Enclosure configuration: (with optional trolley)
1175 x 1480 x 826 mm
46.26 x 58.27 x 32.52 inch -
Weight
Base model:
28.5 kg / 63 lbs
Enclosure configuration:
185.5 kg / 409 lbs (with optional trolley) -
Sampling probe compatibility
Base model and enclosure configuration:
Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46
Hybrid:
Channel 1 – Raman Rxn-20 (with accessory optics)
Channel 2 – Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46 -
Automation interface
OPC
Modbus
HTTPS
(contact us for other options) -
Installation options
Base model and Hybrid:
19-inch rack package
Enclosure configuration:
NEMA 4X enclosure; wall-mountable, moblile trolley, or fixed stand -
Hazardous area certifications
Base model and Hybrid:
ATEX, CSA, IECEx
Enclosure configuration:
Call support for options
-
Measuring principle
Raman spectroscopy
-
Spectral coverage
Base Model and Enclosure configuration:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm) -
Spectral resolution
Base model and Enclosure configuration (average):
5 cm-1 (532 nm)
4 cm-1 (785 nm)
5 cm-1 (1000 nm)
Hybrid:
4 cm-1 (785 nm) average -
Channels
Base model and Enclosure configuration:
Up to four channels
Hybrid:
Up to two channels -
Temperature
Base model:
Operating:
5 to 35 °C / 41 to 95 °F (532 nm, 785 nm)
5 to 30 °C / 41 to 86 °F (1000 nm)
Storage:
-15 to 50 °C / 5 to 122 °F
Hybrid:
Operating: 5 to 35 °C / 41 to 95 °F
Storage: -15 to 50 °C / 5 to 122 °F
Enclosure configuration:
Operating: (all wavelengths)
5 to 50 °C / 41 to 122 °F
Storage:
-15 to 50 °C / 5 to 122 °F -
Relative humidity
20 to 80 %, non-condensing
-
Input voltage
Base model and Hybrid:
100-240 V, 50-60 Hz, ±10%
Enclosure configuration:
120 V ±10%, 60 Hz -OR-
230 V ±10%, 50/60 Hz