Measuring principle
Fieldbus indicators
-
Measuring principle
8 channel field indicator for fieldbuses
-
Function
Display values
Advanced diagnostic -
Display
High contrast backlit LCD with bargraph
TAG/unit -
Power Supply
Not defined
-
Input
Foundation Fieldbus protocol
PROFIBUS PA protocol -
Output
Not defined
-
Output
Not defined
-
Software functions
Listener Mode
On Foundation Fieldbus also function block connection:
Display transducer block
Advanced diagnostic block
2 x input selector
Arithmetic block
Integrator block
PID block -
Certificates
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ic IIC T6
ATEX II2G Ex db IIC T6 Gb
ATEX II2D Ex tb IIIC Db
ATEX II3G Ex nA IIC T6
ATEX II1G Ex ia IIC T4/T5/T6, II2D
CSA General Purpose
CSA IS, NI I / 1+2/A-D
CSA XP,NI,DIP I,II,III/1+2/A-G
CSA XP,NI,DIP IS, NI I, II, III/1+2/A-G
FM IS,NI I / 1+2/A-D
FM XP,NI,DIP I,II,III/1+2/A-G
FM XP,NI, DIP IS, NI I, II, III/1+2/A-G
IECEx Ex ia IIC T6 Ga
IECEx Ex db IIC T6 Gb
IECEx Ex tb IIIC Db -
SIL
Not defined
-
Panel mounting
field
-
Measuring principle
Display
-
Function
Display values
Advanced diagnostic -
Certification
ATEX Ex ia
ATEX Ex d
FM
CSA
IECEx Ex ia
IECEx Ex d
IECEx Ex tD -
Input
Foundation Fieldbus protocol
PROFIBUS PA protocol -
Dimensions (wxhxd)
Field housing:
132 x 135 x 106 mm
(5.2″ x 5.31″ x 4.17″) -
Software
Listener Mode
On Foundation Fieldbus also function block connection:
Display transducer block
Advanced diagnostic block´
2 x input selector
Arithmetic block
Integrator block
PID block -
Operation
Foundation Fieldbus: via fieldbus
PROFIBUS PA: DTM and FieldCare or DIP-switches on the device
Write lock on hardware -
Display
High contrast backlit LCD with bargraph
TAG/unit -
Operating Voltage
9-32 V DC, polarity independent
Field of application
The 8 channel indicator shows measured and calculated values and status information of the fieldbus users in a FOUNDATION Fieldbus™ or PROFIBUS® PA network. In the listener mode the device listens to the set fieldbus addresses and indicates their values. In addition, for FOUNDATION Fieldbus™ values available on the bus can be indicated via function block interconnection. A plain text field allows the display of the engineering unit or of the TAG. A bar graph is available for trend visualization.
Fieldbus indicator with 8 input channels and FOUNDATION Fieldbus™ or PROFIBUS® PA protocol for displaying process values and calculated values.
Benefits
Simple and standardized communication via fieldbus protocolListener mode for up to 8 input channels or digital statusBrilliant, backlit LC display with bar graph, diagnostic symbols and clear text fieldNo external power supply requiredInternational approvals