Spectrometer Memosens Wave CAS80E

  • Measuring principle

    Absorption

  • Application

    Monitoring of WWTP in- and outlet
    Drinking water and surface water

  • Installation

    Insitu (immersion in process), extractive with sample and flow cell

  • Characteristic

    Insitu (immersion in process), extractive with sample and flow cell
    UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measurement range

    “Depending on the path length and the application the measuring range vary:
    TOCeq: 0 to 400 mg/l
    CODeq: 0 to 20 000 mg/l
    BODeq: 0 to 5000 mg/l
    SAC254: 0 to 1000 /m
    TU: 0 to 800 FAU
    TSS: 0 to 10 000 mg/l
    NO3-N: 0 to 500 mg/l
    APHA/Hazen: 0 to 500 Hazen

  • Measuring principle

    UV/VIS absorbance at 200 to 800 nm

  • Design

    40 mm

  • Material

    Housing: stainless steel or titanium
    Windows: sapphire or quartz
    O-rings: EPDM

  • Dimension

    571.4 x 40 mm
    21.5 x 1.6 in

  • Process temperature

    0 to 50°C
    32 to 122 °F

  • Process pressure

    0.5 to 10 bar abs.
    7.3 to 145 psi

  • Temperature sensor

    -20 to 60°C
    -4 to 140 °F

  • Connection

    G1 and NPT 3/4″

  • Ingress protection

    IP68

  • Measuring principle

    UV absorbance

  • Application

    Monitoring of WWTP in- and outlet, drinking water and surface water

  • Characteristic

    Insitu (immersion in process)
    Extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measurement range

    Depending on the path length and the application the measuring range vary:
    TOCeq: 0 to 400 mg/l
    CODeq: 0 to 20 000 mg/l
    BODeq: 0 to 5000 mg/l
    SAC254: 0 to 1000 /m
    TU: 0 to 800 FAU
    TSS: 0 to 10 000 mg/l
    NO3-N: 0 to 500 mg/l
    APHA/Hazen: 0 to 500 Hazen

  • Design

    40 mm

  • Material

    Housing: stainless steel or titanium
    Windows: sapphire or quartz
    O-rings: EPDM

  • Process temperature

    0 to 50°C
    32 to 122 °F

  • Process pressure

    0.5 to 10 bar abs.
    7.3 to 145 psi

  • Temperature sensor

    -20 to 60°C
    -4 to 140 °F

  • Connection

    G1 and NPT 3/4″

  • Ingress protection

    IP68

  • Measuring principle

    UV absorbance

  • Characteristic

    Insitu (immersion in process), extractive with sample and flow cell UV/VIS spectrometer for measurement of TOCeq, CODeq, BODeq, SAC254, TU/TSS, Nitrate, APHA/Hazen color

  • Measuring method

    UV/VIS Absorbance at 200 to 800 nm

  • Size

    571.4 x 40 mm
    21.5 x 1.6 in

  • Design

    40 mm

Spread the love

Contact Us

    Please prove you are human by selecting the tree.