TSC310 Thermocouple sensor, cable probe

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    metric style
    cable probe
    suitable for hazardous areas
    process connection as compression fitting

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    2,0 mm (0,08”)
    3,0 mm (0,12”)
    4,5 mm (0,18”)
    6,0 mm (0,24”)

  • Max. immersion length on request

    up to 100.000,00 mm (3.937,01”)

  • Material protection tube/ thermowell

    1.4401 (316)
    Alloy 600 (2.4816)

  • Process connection

    compression fitting:
    G1/4
    G3/8
    G1/2
    G1/8
    NPT1/4
    NPT1/2
    NPT1/8
    NPT3/8

  • Tip shape

    straight

  • Operating temperature range

    Type K:
    max. 1.100 °C
    (max. 2.012 °F)
    Type J:
    max. 750 °C
    (max. 1.382 °F)

  • Max. process pressure (static)

    at 20 °C: 25 bar (363 psi)

  • Accuracy

    class 2 acc. to IEC 60584

  • Response time

    t50 = 1 s
    t90 = 2 s

  • Integration head transmitter

    no

  • Ex – approvals

    ATEX II
    NEPSI
    IECEx
    UKCA

  • Certification

    Gost Metrology

Field of application
The thermocouple (TC) cable probe is easy to install and provide a high operational safety due to reliable and accurate temperature measurement in common processes. The probe is specially suited to temperature measurement in machinery, laboratory equipment and plants in gaseous or liquid medium like air, water, oil, etc. Without additional thermowell the probe sheath is directly in contact with the process medium. This enables to detect rapid temperature changes fast and accurate.

The resistance thermometer is specially suited to temperature measurement in machinery, power stations and plants in gaseous or liquid media like air, steam, water and oil.

Benefits
High flexibility through user-specific insertion lengths and variable process connectionsFast response timeDifferent types of thermocouples according to DIN EN 60584 and ASTM E230/ANSI MC96.1: type J (Fe-CuNi), type K (NiCr-Ni)Types of protection for use in hazardous locations: Intrinsic Safety (Ex ia) and non-Sparking (Ex nA)NEPSI approval (Ex ia)

Spread the love

Contact Us