Ultrasonic measurement Time-of-Flight Prosonic FMU44

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0,7 bar … 2,5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN100, ASME 4″, JIS 10K 100
    DN150, ASME 6″, JIS 10K 150
    DN200, ASME 8″, JIS 10K 200
    Mounting bracket

  • Blocking distance

    0.5 m (1.9 ft)

  • Max. measurement distance

    Liquids: 20 m (66 ft),
    Solids: 10 m (33 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Fast filling and discharging rate:
    FMU90 + FDU9x
    Level limit detection:
    FMU90 + FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    2-wire HART

  • Accuracy

    +/- 4mm or +/- 0,2 % of set measuring range

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0,7 bar … 2,5 bar abs
    (10 psi … 36 psi)

  • Main wetted parts

    PVDF

  • Process connection

    Flange
    DN100, ASME 4″, JIS 10K 100
    DN150, ASME 6″, JIS 10K 150
    DN200, ASME 8″, JIS 10K 200
    Mounting bracket

  • Blocking distance

    0.5 m (1.9 ft)

  • Max. measurement distance

    Liquids: 20 m (66 ft),
    Solids: 10 m (33 ft)

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, INMETRO, NEPSI

  • Application limits

    Take notice of range diagram

Field of application
The Prosonic FMU44 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Two-wire or four wire instrument for continuous non-contact level and flow measurement.

Process connection: Flange
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +2.5bar (+10 to +36psi)
Maximum measuring distance: Liquids 20m (66ft), Solids 10m (33ft)
Blocking distance: Liquids and Solids 0.5m (1.9ft)
International explosion protection certificates

Benefits
Reliable non-contact measurementQuick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectableEnvelope curves on the on-site display for simple diagnosisHermetically sealed and potted sensorChemically resistant sensor out of PVDFCalibration without filling or dischargingIntegrated temperature sensor for automatic correction of the temperature dependent sound velocity

Spread the love

Contact Us