Measuring principle
Ultrasonic
-
Characteristic / Application
Compact ultrasonic transmitter
-
Supply / Communication
2-wire HART
-
Accuracy
+/- 4mm or +/- 0,2 % of set measuring range
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0,7 bar … 2,5 bar abs
(10 psi … 36 psi) -
Main wetted parts
PVDF
-
Process connection
Flange
DN100, ASME 4″, JIS 10K 100
DN150, ASME 6″, JIS 10K 150
DN200, ASME 8″, JIS 10K 200
Mounting bracket -
Blocking distance
0.5 m (1.9 ft)
-
Max. measurement distance
Liquids: 20 m (66 ft),
Solids: 10 m (33 ft) -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, INMETRO, NEPSI
-
Application limits
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Compact ultrasonic transmitter
-
Supply / Communication
2-wire HART
-
Accuracy
+/- 4mm or +/- 0,2 % of set measuring range
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0,7 bar … 2,5 bar abs
(10 psi … 36 psi) -
Main wetted parts
PVDF
-
Process connection
Flange
DN100, ASME 4″, JIS 10K 100
DN150, ASME 6″, JIS 10K 150
DN200, ASME 8″, JIS 10K 200
Mounting bracket -
Blocking distance
0.5 m (1.9 ft)
-
Max. measurement distance
Liquids: 20 m (66 ft),
Solids: 10 m (33 ft) -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, INMETRO, NEPSI
-
Application limits
Take notice of range diagram
Field of application
The Prosonic FMU44 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
Process connection: Flange
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +2.5bar (+10 to +36psi)
Maximum measuring distance: Liquids 20m (66ft), Solids 10m (33ft)
Blocking distance: Liquids and Solids 0.5m (1.9ft)
International explosion protection certificates
Benefits
Reliable non-contact measurementQuick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectableEnvelope curves on the on-site display for simple diagnosisHermetically sealed and potted sensorChemically resistant sensor out of PVDFCalibration without filling or dischargingIntegrated temperature sensor for automatic correction of the temperature dependent sound velocity