Ultrasonic measurement Time-of-Flight Prosonic FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version

  • Specialities

    Protection Class IP 66 / NEMA 4x
    automatic sensor recognition of FDU9x sensors

  • Supply / Communication

    90 … 253 VAC
    10.5 … 32 VDC
    Profibus DP

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 60 °C
    (-40 °F … 140 °F)

  • Communication

    Profibus DP

  • Certificates / Approvals

    ATEX, CSA

  • Options

    Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display

  • Components

    Sensors FDU9x

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with Field housing or top hat rail housing for control cabinet instrumentation, 5 or 10 channel version

  • Specialities

    Protection Class IP 66 / NEMA 4x
    automatic sensor recognition of FDU9x sensors

  • Supply / Communication

    90 … 253 VAC
    10.5 … 32 VDC
    Profibus DP

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 60 °C
    (-40 °F … 140 °F)

  • Communication

    Profibus DP

  • Certificates / Approvals

    ATEX, CSA

  • Options

    Illuminated display, 6 line graphic display with country specific menu guidance

  • Components

    Sensors FDU9x

Field of application
Prosonic FMU95 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids.

Continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk materials with up to 5 or 10 ultrasonic sensors.
Measuring range up to 45m (148ft) (depending on sensor and material measured)
Calculation of average values or sums

Benefits
Simple, menu-guided operation with 6-line plain text display, 15 languages selectableEnvelope curves on the display for quick and simple diagnosisEasy operation, diagnosis and measuring point documentation with the supplied “FieldCare” operating programTime-of-Flight correction via integrated or external temperature sensorsLinearization (up to 32 points, freely configurable)System integration via PROFIBUS DP with up to 20 measured valuesAutomatic detection of the sensors FDU9x