Measuring principle
Vibration Liquids
-
Characteristic / Application
High protection against aggressive media by using antistatic coating
Modular housing concept
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g.Ex,WHG)
pipe extension up to 3m (6m option) -
Specialities
Foamdetection
Detekt a densitychange
second line of defense -
Supply / Communication
PROFIBUS PA
19…253V AC, 2-wire
10…55V DC-PNP, 3-wire
DPDT, 19…253V AC, 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM, 2-wire
NAMUR with testbutton -
Ambient temperature
-50 °C…+70 °C
(-58 °C…+158 °F) -
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F)
up to 230 °C / 450°F on request -
Process pressure / max. overpressure limit
Vacuum…40 bar
(Vacuum…580 psi) -
Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
-
Main wetted parts
ECTFE
PFA (Edlon)
PFA (Rubyred)
PFA (conductive)
Enamel -
Process connection
Flange:
DN25…DN100,
ASME 1″…3″,
JIS RF10 K 50 -
Process connection hygienic
FDA conform with PFA (Edlon)
-
Sensor length
ECTFE, PFA 130mm, 148mm…3000mm
(ECTFE, PFA 5.12″, 5.83″…118″)
Enamel 130mm, 148mm…1200mm
(Enmal 5.12″, 5.83″…47.24″) -
Communication
PROFIBUS PA
19…253V AC
10…55V DC-PNP
19…253V AC bzw 10…55V DC
8/16mA, 11…36V DC
NAMUR
PFM -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
-
Safety approvals
SIL2/ SIL3
-
Design approvals
EN 10204-3.1
-
Marine approval
GL/ ABS/ DNV
-
Options
Heavy duty stainless steel housing mainly for the oil and gas industry
-
Components
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR
-
Measuring principle
Vibration Density
-
Characteristic / Application
Liquiphant M Density
with Density Computer FML621
Temperature and pressure measurement
High protection against aggressive media by using antistatic coating
Modular housing concept
Wide range of process connections
Pipe extension up to 3 m (6 m option) -
Supply / Communication
Transmitter power supply (MUS)
-
Ambient temperature
-50…80°C
-50…60°C for hazardous applications -
Process temperature
0…80 °C (validity of accuracy data)
-50…0°C / 80…150 °C (with reduced technical data) -
Process pressure
0…25 bar
>25…40 bar (with reduced technical data) -
Wetted parts
ECTFE, PFA and Enamel
-
Sensor length
115…3000 mm
(depends by the covering) -
Output