Measuring principle
Vibration Solids
-
Characteristic / Application
Point level switch for fine grained solids and powder
Grain size: <= 10 mm (<= 0.39 in)
Fork sensor
No calibration required
Not affected by build-up or external vibration
Robust
Switch value visible from outside
Rope extension -
Specialities
Build-up and corrosion detection
Remote version
3 temperature versions available
SIL 2 -
Supply / Communication
10-55V DC PNP 3-wire
19-253V AC 2-wire
19…253V AC / 19…55V DC 2 relay contact
8/16mA
NAMUR
PFM -
Ambient temperature
-50°C … 70°C
(-60°F … 160°F) -
Process temperature
-40°C …80 °C
(-40°F … 170°F) -
Process pressure / max. overpressure limit
Vacuum … 2 bar
(Vacuum … 30 psi)
max. 6 bar / 80 psi for EExd/EExde -
Min. density of medium
Standard fork: 10 g/l
Short fork: 50 g/l -
Main wetted parts
Sensor selectable:316L 3,2um
316L 0,8um
316L PTFE coated (to avoid build-up)
Rope: PUR, Silicon -
Max. tensile strength
3000 N
-
Process connection
Thread
R 1 1/2″
1 1/4″ NPT
1 1/2″ NPT
EN Flange DN50…DN100
ASME Flange 2″…4″
JIS Flange 50A…100A -
Process connection hygienic
Tri-Clamp ISO2852
-
Sensor length
750….20000mm
(30…800″) -
Communication
DC PNP 2-wire
AC Thyristor
DPDT relay
8/16mA
NAMUR
PFM -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN, INMETRO, NEPSI, EAC
-
Safety approvals
SIL
-
Options
Glass cover
Temperature spacerEN10204-3.1 -
Components
PFM: FTL325P, FTL375P
NAMUR: FTL325N, FTL375N
Field of application
Soliphant FTM52 is a robust point level switch for use in silos containing fine-grained or powdery solids even with a low bulk density. Suitable for a wide range of applications with international certificates for use in dust or gas hazardous areas. Available with polished fork and stainless steel housing with Tri-Clamp or with aluminum housing and coated fork. Maintenance-free device for use in typical applications like: cereals, flour, cocoa, sugar, animal feed, dye powder, chalk.
Point level switch for fine grained solids and powder.
Process connections: Threads, flanges and hygienic connection (Tri-Clamp)
Temperature: -40 to +80°C (-40 to +170°F)
Pressure: -1 to +2bar (-14.5 to +30psi)
Sensor length: 750mm to 20,000mm
Sensor material: 316L (3,2µm, 0,8µm, PTFE coated)
International explosion protection certificates
Benefits
SIL2 in accordance with IEC 61508No mechanically moved parts, free of maintenanceMeasurement not affected by build-up or external vibrationVarious electronic inserts: e.g. NAMUR, relay, thyristor and PFM-signal outputs for optimum alignment with the plant control systemBuild-up and abrasion display selectable, density setting and switching delay selectableChoice of coated or polished sensorBuild-up and corrosion detection