The WATERFLUX 3070 is a battery powered electromagnetic water meter for use in water abstraction wells, district metering areas (DMA) and custody transfer measurement of potable water (MI-001, OIML R49). With optional pressure and temperature sensors, the meter can also be used for leak detection, quality control and pressure management systems. Unlike mechanical water meters, the WATERFLUX 3070 is maintenance-free and offers a much larger turn down ratio (1000:1). Its measuring tube with a rectangular and reduced cross-section enables a stable measurement even at low flow rates. Due to the optimized flow profile, the WATERFLUX 3070 can be installed virtually anywhere without straight inlet or outlet runs – behind pipe bends, slide valves or a reduction in the pipe. Even burial installation or use in flooded areas is possible.
Next to battery-powered operation with integrated batteries or optional external battery pack (“PowerBlock”), the WATERFLUX 3070 offers multiple power supply options. For locations with mains power supply, an optional FlexPower unit is available to connect the battery-powered meter to a 110…230V AC or 10…30V DC power source on site, e.g. an electrical grid, a solar panel or a small windmill. For permanent transmission of multiparameter measurement readings (e.g. flow, pressure, temperature), Modbus RTU communication is available as a simple interface. For remote or difficult to access measurement points (e.g. abstraction wells), the water meter can also be equipped with a GPRS or 3G module for remote transmission of readings. A full on-site verification of the WATERFLUX 3070 without process interruption can be carried out using the OPTICHECK service tool.
Specifications
Depending on selected device configuration
General information
Product type | Flowmeter |
Product family name | WATERFLUX |
Product positioning | For district metering of potable water and custody transfer (CT) measurement |
Measurement principle | Electromagnetic |
Measured media | Liquids |
Operating conditions
Process pressure | max. 16 barg/ 230 psig |
Process temperature | -5…+70°C/ +23…+158°F |
Materials
Liner | Polyamide polymer 11 (Rilsan®) |
Process connections
Flange connections | EN (1092-1): DN25…600 ASME (B 16.5): 1…24″ JIS (B 2220): 25…600A |
Thread connections | Male: G1, G1½, G2 |
Installation conditions
Inlet run | 0D |
Outlet run | 0D |
Approvals/Standards
Certificates/Approvals Potable Water | DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS |
Communication
Discrete outputs | Pulse, Status |
Digital outputs | Modbus RTU |