-
Measuring principle
Raman spectroscopy
-
Spectral coverage
Probe spectral coverage is limited by the coverage of the analyzer being used.
-
Maximum laser power into probehead (mW)
< 499
-
Sample interface
Temperature (25.4 mm / 1 inch) standard configuration:
-30 to 120 °C / -22 to 248 °F (316L stainless steel)
-30 to 150 °C / -22 to 302 °F (C276 alloy)
-30 to 150 °C / -22 to 302 °F (Grade 2 titanium)
Temperature (25.4 mm / 1 inch) cryogenic configuration:
-196 to 70°C / -320.8 to 158 °F (C276 alloy)
-196 to 70 °C / -320.8 to 158 °F (Hybrid metal combination)
Temperature (60.33 mm / 2.375 inch) standard configuration:
-30 to 120°C / -22 to 248 °F (316L stainless steel)
-30 to 150 °C / -22 to 302 °F (C276 alloy)
-30 to 150 °C / -22 to 302 °F (Grade 2 titanium)
Temperature ramp:
≤ 30 °C/min
≤ 54 °F/min
Flange: up to 305 mm / 12 inch diameter, ASME B16.5 or DIN EN1092 Type B flanges available upon request
Relative humidity: up to 95%, non-condensing -
Pressure
Min pressure:
Full vacuum (0 bara) but not ultrahigh vacuum (UHV) where outgassing maybe a concern
Max Pressure
25.4 mm / 1 inch standard probe:
141.5 barg / 2053 psig (316L stainless steel)
186.6 barg / 2707 psig (C276 alloy)
144.1 barg / 2090 psig (Grade 2 titanium)
25.4 mm / 1 inch cryogenic probe:
213.7 barg / 3100 psig (C276 alloy)
158.6 barg / 2300 psig (Hybrid metal combination)
60.33 mm / 2.375 inch probe:
49.7 barg / 721 psig (316L stainless steel)
68.8 barg / 998 psig (C276 alloy)
51.5 barg / 747 psig (Grade 2 titanium) -
Wetted materials
316L option
Metal: 316L stainless steel
Window: High-purity sapphire
C276 option
Metal: C276 alloy
Window: High-purity sapphire
Titanium option
Metal: Grade 2 titanium
Window: High-purity sapphire
Hybrid metal combination option
Metal: 316L stainless steel, C276 alloy
Window: High-purity sapphire -
Fiber optic cable
Cable sold separately
-
Length
Maximum immersible length is dependent on material choice
-
Diameter
25.4 or 60.33 mm
1 or 2.375 inch
(25.4 mm / 1 inch only for Grade 2 Titanium) -
Hazardous area certifications
ATEX, CSA, IECEx
Field of application
The Raman Rxn-41 probe is a rugged, process insertion probe with no sample handling system. Its single cable design streamlines installation, eliminates risk scenarios, and minimizes installation cost for long fiber runs in the process environment. The Rxn-41 probe is ideally suited for use in chemical plants and refineries to measure batch or continuous flow production. For direct measurements in cryogenic fluids, an optimized cryogenic version of the Raman Rxn-41 probe is available.
Chemical: reaction monitoring, blending, feed and final product monitoringPolymer: polymerization reaction monitoring, polymer blendingPharmaceutical: API reaction monitoring, crystallization, polymorph, drug substance production unit operationOil & Gas: fuel blending, fuel characterization
Benefits
Constructed to individual site requirementsSealed probe designIntegrated “laser on” indicatorOne in/one out fiber opticsDirect insertion compatibilityMeets Category 1 pressure equipment safety standardsSuitable for hazardous area/classified environments