Proline t-mass F 500 thermal mass flowmeter
Inline flowmeter with long-term stability as remote version with up to 4 I/Os
-
Measuring principle
Thermal
-
Product headline
Inline flowmeter with long-term stability as remote version with up to 4 I/Os.
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof.
Measurement of utility and process gases as well as gas mixtures in small line sizes. -
Sensor features
High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor.
Inline version with DN 15 to 100 (½ to 4″). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 15 to DN 100 (1/2″ to 4″)
-
Wetted materials
Measuring tubes
• DN 15 to 50 (½ to 2″): stainless cast steel, CF3M/1.4408
• DN 65 to 100 (2½ to 4″): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
• Stainless steel, 1.4404 (316/316L)
• Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L) -
Measured variables
Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
-
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
-
Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
-
Max. process pressure
PN40 / Cl. 300 / 20K
-
Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)
-
Ambient temperature range
-40 to 60°C (-40 to 140°F)
Optional:
Transmitter: -50 to 60°C (-50 to 140°F),
Sensor: -60 to 60°C (-60 to 140°F) -
Transmitter housing material
Aluminium, AlSi10Mg, coated
Polycarbonate -
Degree of protection
IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)
-
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, Modbus RS485
-
Power supply
DC 24V
AC 100 to 240V -
Hazardous area approvals
ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
-
Product safety
CE, C-tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Proline t-mass B 150 thermal mass flowmeter
The flowmeter for cost-effective measurement and easy monitoring of utility gases
-
Measuring principle
Thermal
-
Product headline
The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts. -
Sensor features
Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement.
Insertion version for nominal diameter DN 80 to 1500 (3 to 60″). Installation and removal of sensor without process interruption. Easy installation. -
Transmitter features
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter. -
Nominal diameter range
DN 80 to 1500 (3 to 60″)
-
Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G -
Measured variables
Mass flow, temperature, corrected volume flow, FAD volume flow
-
Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature “Calibration flow”) -
Measuring range
20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature “Calibration flow”) -
Max. process pressure
20 bar g (290 psi g)
-
Medium temperature range
–40 to +100 °C (–40 to +212 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line display with push Buttons
Configuration via local display and operating tools possible -
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
-
Power supply
DC 18 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
CRN
Field of application
The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Device properties
Insertion version for nominal diameter DN 80 to 1500 (3 to 60″)
Installation and removal of sensor without process interruption
Easy installation
Device in compact version with DC 24 V power supply
4-20 mA HART, pulse/frequency/switch output
Compact and robust transmitter
Benefits
Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ductsOptimal process monitoring – easy measurement even at low pressures and flow velocitiesCost-effective measurement – easy installation, negligible pressure loss and maintenance-freeReliable flow trending – multivariable measurementFast and efficient commissioning – guided operating menusHigh plant availability – self-diagnostics and error monitoringAutomatic recovery of data for servicing
Proline t-mass A 150 thermal mass flowmeter
The flowmeter for cost-effective measurement and easy monitoring of utility gases
-
Measuring principle
Thermal
-
Product headline
The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes. -
Sensor features
Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement.
Inline version: DN 15 to 50 (½ to 2″). Process pressure up to PN 40, Class 300. A variety of process connections available. -
Transmitter features
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter. -
Nominal diameter range
DN 15 to 50 (½ to 2″)
-
Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L) -
Measured variables
Mass flow, temperature, corrected volume flow, FAD volume flow
-
Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature “Calibration flow”) -
Measuring range
0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature “Calibration flow”) -
Max. process pressure
PN 40, Class 300
-
Medium temperature range
–40 to +100 °C (–40 to +212 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line display with push Buttons
Configuration via local display and operating tools possible -
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
-
Power supply
DC 18 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
Field of application
The t-mass A 150 device is specially designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. its 4-wire technology is contained within a rugged compact aluminum housing. It is orderable either with display or as a blind version. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Device properties
Inline version: nominal diameter DN 15 to 50 (1/2 to 2″)
Process pressure up to PN 40, Class 300
A variety of process connections available
Device in compact version with DC 24 V power supply
4-20 mA HART, pulse/frequency/switch output
Compact and robust transmitter
Benefits
Suitable for air, nitrogen, carbon dioxide and argon in small line sizesOptimal process monitoring – easy measurement even at low pressures and flow velocitiesCost-effective measurement – easy installation, negligible pressure loss and maintenance-freeReliable flow trending – multivariable measurementFast and efficient commissioning – guided operating menusHigh plant availability – self-diagnostics and error monitoringAutomatic recovery of data for servicing
Proline Promag W 10 electromagnetic flowmeter
Flowmeter for basic water and wastewater applications with easy-to-use operation concept
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
Suitable for elementary measurement tasks such as raw water intake. -
Sensor features
Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform. -
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display. -
Nominal diameter range
DN 25 to 3000(1 to 120″)
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194°F) -
Ambient temperature range
-40 to 60°C (-40 to 140°F)
-
Sensor housing material
DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 350 to 2000 (14 to 78″): Carbon steel with protective varnish -
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 -
Display/Operation
LCD display with touch & auto rotate
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
CSA, GP, KC
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
CRN, PED
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approvals: ACS, KTW/W270, NSF 61, WRAS BS 6920
Field of application
Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.Suitable for elementary measurement tasks such as raw water intake.Device propertiesInternational drinking water approvalsDegree of protection IP68 (Type 6P enclosure)System integration with HART, Modbus RS485Flexible operation with app and optional display
Benefits
Proline Promag W 800 electromagnetic flowmeter
Long-lasting battery-powered magmeter with secure system integration and communication
-
Measuring principle
Electromagnetic
-
Product headline
Battery-powered flowmeter with EN ISO 12944 corrosion protection & intelligent energy efficient mode.
For direct underground installation or permanent underwater use.
Certified sensor for the most demanding water and wastewater applications. -
Sensor features
Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). -
Transmitter features
Secure data storage and transmission – worldwide
encrypted communication over the mobile network . Convenient commissioning and operation – device
access via Bluetooth using intuitive SmartBlue app. Integrated verification – Heartbeat Technology.
Transmitter housing made of durable polycarbonate. Battery lifetime up to 15 years. Measuring intervals can be adapted individually. -
Nominal diameter range
DN 25 to 900 (1 to 36″)
-
Wetted materials
Liner: polyurethane; PTFE; hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Volume flow
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
-
Measuring range
9 dm³/min to 22500 m³/h (2.5 to 100000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material hard rubber: 0 to +70 °C (+32 to +158 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: -20 to 90°C (–4 to +194 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 350 to 900 (14 to 36″): Carbon steel with protective varnish -
Transmitter housing material
Polycarbonat
-
Degree of protection
Compact version: IP66/67, type 4X enclosure and IP68, type 6P enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible; Remote data access via mail and SMS -
Outputs
3x Pulse/switch output (passive); Modbus RS485
-
Inputs
Status input
-
Digital communication
LTE Cat M1; LTE Cat NB1; LTE Cat NB2; GPRS; EGPRS
-
Power supply
Internal:
Batteries per DC 3.6 V External:
AC 85 to 265 V (47 to 63 Hz) / DC 19 to 30 V -
Hazardous area approvals
CSA, GP
-
Product safety
CE Marking, EAC Marking, UKCA Marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Custody transfer according to MI‐001
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
CRN, PED
-
Hygienic approvals and certificates
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920
Field of application
Promag W 800 is ideal for off-grid applications in the water industry, even flow measurement in direct underground installation or underwater. Promag 800 covers basic functionality, Promag 800 Advanced offers the full performance spectrum. The battery-powered transmitter provides worldwide transmission of measured data without additional energy supply. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to the measurement of industrial or municipal water and wastewaterDevice propertiesInternational drinking water approvalsDegree of protection IP68 (Type 6P enclosure)Transmitter housing made of durable polycarbonateBattery lifetime up to 15 yearsMeasuring intervals can be adapted individually
Benefits
With corrosion protection for underground installation or permanent underwater use Improved process safety – leakage detection with low flow and pressure measurement Reliable measurement – accurate measured values even with 0 x DN inlet run Long-term operation – robust and completely welded sensor Secure data storage and transmission – worldwide encrypted communication over the mobile network Convenient commissioning and operation – device access via Bluetooth using intuitive SmartBlue app Integrated verification – Heartbeat Technology
Proline Promag W 500 electromagnetic flowmeter
Specialist for demanding water and wastewater applications as remote version with up to 4 I/Os
-
Measuring principle
Electromagnetic
-
Product headline
Specialist for demanding water and wastewater applications as remote version with up to 4 I/Os.
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
Dedicated to the measurement of industrial or municipal water and wastewater . -
Sensor features
Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 25 to 3000(1 to 120″)
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec -
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 25 to 2400 (1 to 90″): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval
Proline Promag P 10 electromagnetic flowmeter
Flowmeter for basic process applications with easy-to-use operation concept
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic process applications with easy-to-use operation concept.
Dedicated to chemical and process applications with corrosive liquids. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display. -
Nominal diameter range
DN 15 to 600 (½ to 24″)
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
-
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 15 to 300 (½ to 12″”): AlSi10Mg, coated
DN 350 to 600 (14 to 24″”): Carbon steel with protective varnish -
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
Standard: IP66/67, Type 4X enclosure
-
Display/Operation
2.4″ LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, KC, JPN, UK Ex
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Driking water approvals: ACS; NSF61, WRAS
Field of application
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With its straightforward hard- and software design, Promag P 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables safe processes.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.Dedicated to chemical and process applications with corrosive liquids.Device propertiesNominal diameter: max. DN 600 (24″)All common Ex approvalsLiner made of PTFE or PFASystem integration with HART, Modbus RS485Flexible operation with app and optional display
Benefits
Diverse applications – wide variety of wetted materialsEnergy-saving flow measurement – no pressure loss due to cross section constrictionMaintenance-free – no moving partsOptimum usability – operation with mobile devices and SmartBlue app or display with touch screenSimple, time-saving commissioning – guided parameterization in advance and in the fieldIntegrated verification – Heartbeat Technology
Proline Promag P 500 electromagnetic flowmeter
High-temperature flowmeter for process applications as remote version with up to 4 I/Os
-
Measuring principle
Electromagnetic
-
Product headline
High-temperature flowmeter for process applications as remote version with up to 4 I/Os.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
DN 15 to 600 (½ to 24″)
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum;
Titanium; Duplex 1.4462 (UNS S31803) -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
Proline Promag P 200 electromagnetic flowmeter
The flowmeter for highest medium temperatures with genuine loop-powered technology
-
Measuring principle
Electromagnetic
-
Product headline
The flowmeter for highest medium temperatures with genuine loop-powered technology.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 200 (8″). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 15 to 200 (½ to 8″)
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum -
Measured variables
Volume flow, mass flow
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
-
Measuring range
4 dm3/min to 1100 m3/h (1 to 4850 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
AlSi10Mg, coated
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
-
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex
-
Other approvals and certificates
-
Product safety
CE, C-Tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
CRN, PED
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approvals: ACS, NSF 61
Field of application
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With genuine loop-powered technology, Promag P 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to chemical and process applications with corrosive liquids and high medium temperaturesDevice propertiesNominal diameter: max. DN 200 (8″)All common Ex approvalsLiner made of PTFE or PFALoop-powered technologyRobust two-chamber housingPlant safety: worldwide approvals (SIL, Haz. area)
Benefits
Versatile applications – wide variety of wetted materialsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsConvenient device wiring – separate connection compartmentSafe operation – no need to open the device due to display with touch control, background lightingIntegrated verification – Heartbeat Technology
Proline Promag P 100 electromagnetic flowmeter
The flowmeter for highest medium temperatures with an ultra-compact transmitter
-
Measuring principle
Electromagnetic
-
Product headline
The flowmeter for highest medium temperatures with an ultra-compact transmitter.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24″). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Local display available. -
Nominal diameter range
DN 15 to 600 (½ to 24″)
-
Wetted materials
Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803) -
Measured variables
Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s -
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish -
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible -
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
-
Power supply
DC 20 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO
-
Other approvals and certificates
-
Product safety
CE, C-Tick
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC
17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approval: ACS, NSF 61, WRAS
Field of application
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to chemical and process applications with corrosive liquids and high medium temperaturesDevice propertiesNominal diameter: max. DN 600 (24″)All common Ex approvalsLiner made of PTFE or PFARobust, ultra-compact transmitter housingLocal display available
Benefits
Versatile applications – wide variety of wetted materialsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsSpace-saving transmitter – full functionality on the smallest footprintTime-saving local operation without additional software and hardware – integrated web serverIntegrated verification – Heartbeat Technology
Proline Promag H 10 electromagnetic flowmeter
Flowmeter for basic hygienic applications with easy-to-use operation concept
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic hygienic applications with easy-to-use operation concept.
For applications with sanitary requirements. -
Sensor features
Flexible installation concept – numerous hygienic process connections. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP-/SIP-cleanable. -
Transmitter features
Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display. -
Nominal diameter range
DN 2 to 150 (¹⁄₁₂ to 6″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone) -
Measured variables
Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity -
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
Standard: IP66/67, type 4X enclosure
-
Display/Operation
2.4″ LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
CSA, GP, KC
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP
Field of application
Promag H is the preferred sensor for hygienic applications in the food and beverage and life sciences industries. With its straightforward hard- and software design, Promag H 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.For applications with sanitary requirements.Device propertiesLiner made of PFASensor housing made of stainless steel (3-A, EHEDG)Wetted materials CIP-/SIP-cleanableSystem integration with HART, Modbus RS485Flexible operation with app and optional display
Benefits
Flexible installation concept – numerous hygienic process connectionsEnergy-saving flow measurement – no pressure loss due to cross section constrictionMaintenance-free – no moving partsOptimum usability – operation with mobile devices and SmartBlue app or display with touch screenSimple, time-saving commissioning – guided parameterization in advance and in the fieldIntegrated verification – Heartbeat Technology
Proline Promag H 500 electromagnetic flowmeter
Specialist for hygienic applications, as remote version with up to 4 I/Os
-
Measuring principle
Electromagnetic
-
Product headline
Specialist for hygienic applications, as remote version with up to 4 I/Os.
Dedicated to demanding applications in the food and beverage as well as in life sciences industries. -
Sensor features
Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP, SIP cleanable. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
-
Nominal diameter range
DN 2 to 150 (¹⁄₁₂ to 6″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Measured variables
Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4409 (CF3M), similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
EHEDG, 3-A, liner and seals acc. to FDA, cGMP
Field of application
Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. With its innovative remote transmitter Promag H 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables compliance and process safety at all times.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to demanding applications in the food and beverage as well as in life sciences industriesDevice propertiesLiner made of PFASensor housing made of stainless steel (
Proline Promag H 300 electromagnetic flowmeter
Specialist for hygienic applications with a compact, easily accessible transmitter
-
Measuring principle
Electromagnetic
-
Product headline
Specialist for hygienic applications with a compact, easily accessible transmitter.
Dedicated to demanding applications in the food and beverage as well as in life sciences industries. -
Sensor features
Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Wetted materials CIP, SIP cleanable. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. -
Nominal diameter range
DN 2 to 150 (¹⁄₁₂ to 6″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Measured variables
Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
-
Degree of protection
IP66/67, type 4X enclosure
IP69 -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Proline Promag H 200 electromagnetic flowmeter
Flowmeter for smallest flow rates with genuine loop-powered technology
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for smallest flow rates with genuine loop-powered technology.
Dedicated to the measurement of the smallest flow quantities. -
Sensor features
Flexible installation concept – numerous process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Liner made of PFA. Sensor housing made of stainless steel. Various electrode materials available. -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 2 to 25 (¹⁄₁₂ to 1″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Measured variables
Volume flow, mass flow
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
-
Measuring range
0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
-
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex
-
Product safety
CE, C-Tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
Field of application
Promag H is the preferred sensor for applications with highest requirements in the chemical and life sciences industries. With its genuine loop-powered technology, Promag H 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
The measuring principle is virtually independent of pressure, density, temperature and viscosityDedicated to the measurement of the smallest flow quantitiesDevice propertiesLiner made of PFASensor housing made of stainless steelVarious electrode materials availableLoop-powered technologyHigh ingress protection: IP69Plant safety: worldwide approvals (SIL, Haz. area)
Benefits
Flexible installation concept – numerous hygienic process connectionsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsConvenient device wiring – separate connection compartmentSafe operation – no need to open the device due to display with touch control, background lightingIntegrated verification – Heartbeat Technology
Proline Promag E 100 electromagnetic flowmeter
The economical flowmeter with an ultra-compact transmitter
-
Measuring principle
Electromagnetic
-
Product headline
The economical flowmeter with an ultra-compact transmitter.
Fully suitable for basic applications in the chemical and process industry. -
Sensor features
Cost-effective sensor – ideal solution for basic requirements. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24″). Ex approvals for Zone 2. Liner made of PTFE. -
Transmitter features
Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Local display available. -
Nominal diameter range
DN 15 to 600 (½ to 24″)
-
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–10 to +110 °C (+14 to +230 °F)
-
Ambient temperature range
–10 to +60 °C (+14 to +140 °F)
-
Sensor housing material
DN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish -
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible -
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
-
Power supply
DC 20 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, EAC
-
Product safety
CE, C-Tick
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED
-
Material certificates
3.1 material
Field of application
The proven sensor for economical measurement of conductive liquids, Promag E, serves various basic applications in the chemical and process industry. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag E 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosityFully suitable for basic applications in the chemical and process industry.Device propertiesNominal diameter: max. DN 600 (24″)Ex approvals for Zone 2Liner made of PTFERobust, ultra-compact transmitter housingLocal display available
Benefits
Cost-effective sensor – ideal solution for basic requirementsEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsSpace-saving transmitter – full functionality on the smallest footprintTime-saving local operation without additional software and hardware – integrated web serverIntegrated verification – Heartbeat Technology
Proline Promag D 10 electromagnetic flowmeter
Highly cost-effective wafer flowmeter with easy-to-use operation concept
-
Measuring principle
Electromagnetic
-
Product headline
Highly cost-effective wafer flowmeter with easy-to-use operation concept.
For basic water applications, optimized for limited space and plastic pipe installations. -
Sensor features
Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals. -
Transmitter features
Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
2-line display with push buttons. Device as compact or remote version. HART. -
Nominal diameter range
DN 25 to 100 (1 to 4″)
-
Wetted materials
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L) -
Measured variables
Volume flow, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
-
Max. process pressure
PN 16, Class 150, 10K
-
Medium temperature range
Liner material polyamide: 0 to +60°C (+32 to +140°F)
-
Ambient temperature range
-40 to 60°C (-40 to 140°F)
-
Sensor housing material
DN 25 to 100 (1 to 12″): AlSi10Mg, coated
-
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure -
Display/Operation
LCD display with touch & auto rotate
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
CSA, GP
-
Product safety
Product safety
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Hygienic approvals and certificates
Hygienic approvals and certificates
Field of application
The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. With its straightforward hard- and software design, Promag D 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.For basic water applications; optimized for limited space and plastic pipe installationsDevice propertiesShort installation length and low weightIntegrated ground disks made of stainless steelInternational drinking water approvalsSystem integration with HART, Modbus RS485Flexible operation with app and optional display
Benefits
Easy, fast centering of the sensor – innovative housing construction Energy-saving flow measurement – no pressure loss due to cross section constriction Maintenance-free – no moving parts Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen Simple, time-saving commissioning – guided parameterization in advance and in the field Integrated verification – Heartbeat Technology
Dosimag electromagnetic flowmeter
Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.
For demanding dosing and filling applications. -
Sensor features
High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1″). Measuring device conform to FDA. -
Transmitter features
Versatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – stainless steel housing.
Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter. -
Nominal diameter range
DN 4 (⁵⁄₃₂”), 8 (⁵⁄₁₆”), 15 (½”), 25 (1″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum -
Measured variables
Volume flow
-
Max. measurement error
±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)
±0.5 % o.r. ± 1 mm/s (0.04 in/s)
±5 % o.r. -
Measuring range
0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
-
Max. process pressure
PN 16
-
Medium temperature range
Seal material EPDM: –20 to +130 °C (–4 to +266 °F)
Seal material Silicone: –20 to +130 °C (–4 to +266 °F)
Seal material Viton: 0 to +150 °C (+32 to +302 °F) -
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4308 (304)
-
Transmitter housing material
1.4308 (304)
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
No local Operation
Configuration via operating tools possible -
Outputs
Pulse/frequency/switch output (passive)
-
Inputs
None
-
Digital communication
Modbus RS485
-
Power supply
DC 20 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus
-
Product safety
CE
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025)
NTEP -
Material certificates
3.1 material
-
Hygienic approvals and certificates
Sanitary approval: 3-A, EHEDG, seals acc. to FDA
Field of application
Dosimag is specially designed for filling and bottling applications of conductive liquids. It measures volume directly. Designed for applications where space is a premium, Dosimag will be the preferred choice for system integrators, skid builders and equipment manufacturers.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
For demanding dosing and filling applications.
Device properties
Wetted materials CIP, SIP cleanable
Nominal diameter: DN 4 to 25 (1/8 to 1″)
Measuring device conform to FDA
Pulse/frequency/switch output, Modbus RS485
Custody transfer approvals (MID, NTEP)
Excellent and easy cleanable transmitter
Benefits
High process safety – high measuring accuracy and repeatability in shortest filling timeEnergy-saving flow measurement – no pressure loss due to cross-section constrictionMaintenance-free – no moving partsVersatile and time-saving wiring – plug connectorIndustry-optimized – ultra-compact designFor hygiene requirements – stainless steel housing
Proline Teqwave MW 500 – Total solids meter
Inline measuring device for total solids measurement in wastewater sludge as remote version with up to 4 I/Os
-
Measuring principle
Total solids measurement via microwave transmission
-
Product headline
Total solids measurement for the water and wastewater industry, remote version with up to 4 I/Os. Supports sludge treatment processes (from primary sludge to dewatered sludge).
-
Sensor features
Polished tube – less maintenance due to reduced adhesion.
Fewer process measuring points – multivariable measurement (total solids, temperature, conductivity).
Easy installation – proven sensor construction. -
Transmitter features
Full access to process and diagnostic information –numerous, freely combinable I/Os.
Onboard load calculation – less effort needed in programming.
Integrated verification – Heartbeat Technology. -
Nominal diameter range
DN 50 to 300
-
Installation
Inline installation
-
Material
Measuring tube:
Stainless steel 1.4408 according to DIN EN 10213, CF3M according to ASME A351)
Temperature sensor:
1.4435 (316L) -
Measurement range
0 to 500 g/l (0 to 31 lb/ft3), 0 to 50%
-
Connection
Wafer
-
Ingress protection
IP66/67, Type 4X enclosure
-
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Output / communication
4-20mA HART, Modbus RS485
-
Power supply
AC 100 to 240 V / AC/DC 24 V
-
Product safety
CE Marking, UKCA Marking
-
Hazardous area approvals
ATEX, IECEx, CSA C/US
-
Material certificates
3.1 material
-
Metrological approvals and certificates
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Field of application
The measuring device Teqwave MW 500 enhances sludge treatment in wastewater treatment plants through real-time total solids measurement using microwave transmission. This allows quicker, more efficient process optimization and fewer lab measurements. Continuous data availability improves solid-liquid separation, boosts operational safety, and enables swift response to process changes. Typical applications in sludge treatment include clarification, digestion, and dewatering.
The remote transmitter version Proline 500 allows for maximum installation flexibility in challenging environments. Equipped with a built-in web server and optional integrated WLAN, it simplifies operation and provides additional process and device information.
Benefits
Reliable, real-time measuring performance – permanent in-line measurement with excellent repeatabilityLess maintenance – polished measuring tube reduces build-up formation and extends cleaning intervalsReduced effort in programming – onboard load rate calculation available in combination with a flowmeterFewer process measuring points – multivariable measurement (total solids, temperature, conductivity)Easy installation – innovative sensor construction and state-of-the-art technology with web server (optional WLAN)Full access to process and diagnostic information – numerous freely combinable I/Os availableIntegrated verification – Heartbeat Technology enables documented device functionality without process interruption
Proline Teqwave MW 300 – Total solids meter
Inline measuring device for total solids measurement in wastewater sludge with a compact, easily accessible transmitter
-
Measuring principle
Total solids measurement via microwave transmission
-
Product headline
Total solids measurement for the water and wastewater industry, with a compact, easily accessible transmitter. Supports sludge treatment processes (from primary sludge to dewatered sludge).
-
Sensor features
Polished tube – less maintenance due to reduced adhesion.
Fewer process measuring points – multivariable measurement (total solids, temperature, conductivity).
Easy installation – proven sensor construction. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os.
Onboard load calculation – less effort needed in programming.
Integrated verification – Heartbeat Technology. -
Nominal diameter range
DN 50 to 300
-
Installation
Inline installation
-
Material
Measuring tube:
Stainless steel 1.4408 according to DIN EN 10213, CF3M according to ASME A351)
Temperature sensor:
1.4435 (316L) -
Measurement range
0 to 500 g/l (0 to 31 lb/ft3), 0 to 50%
-
Connection
Wafer
-
Ingress protection
IP66/67, Type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible -
Output / communication
4-20mA HART, Modbus RS485
-
Power supply
AC 100 to 240 V / AC/DC 24 V
-
Product safety
CE Marking, UKCA Marking
-
Hazardous area approvals
ATEX, IECEx, CSA C/US
-
Material certificates
3.1 material
-
Metrological approvals and certificates
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Field of application
The measuring device Teqwave MW 300 enhances sludge treatment in wastewater treatment plants through real-time total solids measurement using microwave transmission. This allows quicker, more efficient process optimization and fewer lab measurements. Continuous data availability improves solid-liquid separation, boosts operational safety, and enables swift response to process changes. Typical applications in sludge treatment include clarification, digestion, and dewatering.
The space-saving compact transmitter version Proline 300 is designed with a high degree of flexibility in mind, accommodating various operational and system integration needs. It provides access from one side, a remote display, and enhanced connectivity features. For easy operation and to provide additional process and device information, it comes with a built-in web server and optional integrated WLAN.
Benefits
Reliable, real-time measuring performance – permanent in-line measurement with excellent repeatabilityLess maintenance – polished measuring tube reduces build-up formation and extends cleaning intervalsReduced effort in programming – onboard load rate calculation available in combination with a flowmeterFewer process measuring points – multivariable measurement (total solids, temperature, conductivity) Easy installation – innovative sensor construction and state-of-the-art technology with web server (optional WLAN)Full access to process and diagnostic information – numerous freely combinable I/Os availableIntegrated verification – Heartbeat Technology enables documented device functionality without process interruption
Fieldgate SFG500 Intelligent Ethernet/PROFIBUS gateway
Parallel access to PROFIBUS networks, monitoring of PROFIBUS and HART device status
iTHERM ModuLine TT151 Barstock thermowell
Metric thermowell for a wide range of heavy duty industrial applications
-
Measuring principle
Bar stock Thermowell
-
Characteristic / Application
metric style
compliant according to ASME, DIN or NAMUR standard
universal use -
Head connection
internal thread:
M14x1,5
M18x1,5
M20x1,5
M27x2
1/2″ NPT
1/2″ NPSM
1/2″NPSC
G1/2″
G3/4″
M24x1,5 sliding -
Maximum standard immersion length
1500 mm
-
Process connection
To be
threaded
weld in
with flange according to ASME, EN or ISO -
Thermowell root diameter
9…50 mm
-
Medium contact material
Wide selection of materials including:
316
316L
316Ti
347
310
Alloy600
AlloyC276
10CrMo9-10
13CrMo4-5
16Mo3
A105
C22.8
Duplex
Titan Gr.2
316+316L dual rated
P355NH -
Wetted part finishing (Ra)
< 0.8 μm (31.50 μin)
< 1.6 μm (63.00 μin)
DIN Standard -
Tip shape
Straight
Tappered
Stepped
partly tappered -
Temperature range
-200…1100 °C (-328…2.012 °F)
Depending on Configuration -
Max. process pressure (static)
500 bar (7252 psi)
Depending on Configuration -
Max. process pressure at 400 °C
depends on process connection and material
Field of application
The TT151 thermowell is designed as per DIN 43772, ASME B40.9, NAMUR NE 170 norms or as individual configuration. The robust protection tube ensures safe and accurate measurements in process lines or vessels, shielding temperature sensors from harsh environments. It is drilled and machined from solid bar stock with root diameters from 9 to 50 mm. Tips are available in straight, tapered or stepped form. Process connections include a selection of standard flanges, threads or weld-in versions.
Protects the temperature sensor against physical and chemical stressHigh robustness for challenging process conditionsPressure range: up to 500 bar (7252 psi)For use in pipes, vessels or tanksEasier maintenance and recalibration of the measuring point (sensor can be replaced without interrupting the process)
Benefits
TT151 is an industry standard thermowell manufactured from round barstock Modular configuration according to DIN 43772, ASME B40.9, NAMUR NE 170 or more flexible as universal version Extension, immersion length and total length can be chosen according to process requirements Wide range of dimensions, materials and process connections available iTHERM TwistWell in helical design – reducing vortex induced vibrations in high-velocity applications
TR66 Explosion-proof Pt100 Thermometer
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style metric
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
suitable for high process pressures
threaded process connection
with neck
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
20 mm (0,79″)
24 mm (0,94″)
25 mm (0,98″) -
Max. immersion length on request
up to 5.000,00 mm (196,85”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4404 (316L)
1.4571 (316Ti)
AlloyC276
Alloy600 -
Optional coating
Not defined
-
Process connection
male thread:
NPT3/4″
NPT1″
flange:
ASME 1″ 150 RF (B16.5)
ASME 1″ 300 RF (B16.5)
ASME 1″ 600 RF (B16.5)
ASME 1,5″ 150 RF (B16.5)
ASME 1,5″ 300 RF (B16.5)
ASME 1,5″ 600 RF (B16.5)
ASME 2″ 300 RF (B16.5)
ASME 2″ 600 RF (B16.5) -
Tip shape
tapered
-
Surface roughness Ra
1,6 μm (63,0 μin.)
-
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II
IECEx
EAC Ex
Explosion proof
UKCA -
Certification
Gost Metrology
SIL (transmitter only)
Marine approval
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust protection tubes and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors.
Heavy duty applications
Oil & Gas processing industry
Measuring range: -200 to +600 °C (-328 to 1112 °F)
Static pressure range up to 100 bar (1450 psi)
Protection class: IP68
Benefits
Types of protection for use in hazardous locations: Intrinsic safety (Ex i.a.), flameproof (Ex d), non-sparking (Ex nA)High degree of insert compatibility and design as per DIN 43772Extension neck to protect the head transmitter from overheatingFast response time with reduced/tapered tip formHigh degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths Marine approval
iTEMP TMT72 Temperature transmitter
Transformation of sensor signals into stable and standardized output signals for all industries
-
Measuring principle
Head transmitter
-
Input
1 x RTD, TC, Ohm, mV
-
Output
1 x analog 4…20 mA / HART
-
Auxiliary power supply
10…36 V DC (Head transmitter)
11…36 V DC (DIN rail device)
10/11…30 V DC (Ex ia) -
Communication
HART-protocol
Bluetooth® wireless technology -
Installation
Terminal head form B / DIN rail / field mount housing
-
Accuracy
(Pt100, -50…200 °C) <= 0,1 K
(Pt100, -58…392 °F) <= 0,18 °F -
Galvanic isolation
yes
-
Certification
ATEX II1G Ex ia IIC T6
ATEX II3G Ex ic IIC T6 Gc
ATEX II3D Ex tc IIIC Dc
ATEX II3G Ex nA IIC T6 Gc
ATEX II2G Ex ia IIC T6 Gb, II3D
ATEX II3G Ex nA IIC T6 Gc, II3D
ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
CSA C/US General Purpose
CSA C/US IS, Ex ec I/1+2/A-D
CSA C/US XP, DIP I, II, III/1+2/A-G
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
IECEx Ex nA IIC T6 Gc
IECEx Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex ia IIC T6 Ga
INMETRO Ex d T6 Gb, Ex tb IIIC Db
INMETRO Ex nA IIC T6 Gc
NEPSI Ex ia IIC T6 Ga
NEPSI Ex d IIC T6 Gb
NEPSI Ex nA II T6 Gc
UK II1G Ex ia IIC T6 Ga
UK II3D Ex tc IIIC Dc
UK II2G Ex ia IIC T6 Ga, II3D Ex ia IIIC Dc
UK II3G Ex nA IIC Gc, II3D Ex tc IIIC Dc
UK II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db
ATEX IECEx II1G Ex ia IIC T6 Ga
ATEX IECEx II2D Ex tb IIIC Db
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth® interface for remote operation via Endress+Hauser SmartBlue App.
Bluetooth®-enabled temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signalImproved process efficiency and increased plant uptimeUniversal input for RTD, TC, resistance transmitters (Ω), voltage transmitters (mV)Installation in terminal head form B (flat face) as per DIN EN 50446Installation in cabinets with DIN rail housingOptional installation in field housing even for use in Ex d applications
Benefits
Safe operation in hazardous areas thanks to international approvals Reliable operation thanks to sensor and device monitoring Integrated Bluetooth® interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional Diagnostics information according to NAMUR NE 107 Available with plug-on display TID10Optimization of the measurement accuracy by sensor-transmitter matching.
iTEMP TMT162 Temperature field transmitter
Electronic monitoring, conversion and display of input signals – all over the industries
-
Measuring principle
Field transmitter
-
Input
2 x RTD, TC, Ohm, mV
-
Output
1 x analog 4…20 mA / HART
FOUNDATION Fieldbus H1
PROFIBUS PA -
Auxiliary power supply
11,5…42 V DC (HART)
11,5…30 V DC (Ex ia)
9…32 V DC (FF, PA)
10,5…24 V DC (Ex ia, FF, PA) -
Communication
HART
FOUNDATION Fieldbus
PROFIBUS PA -
Installation
in field
-
Accuracy
(Pt100) <= 0,1 K (HART, FF, PA)
(Pt100) <= 0,18 °F (HART, FF, PA) -
Galvanic isolation
yes
-
Certification
UL rec. Comp (HART)
FM IS, NI I/1+2/ABCD
CSA IS, NI I/1+2/ABCD
ATEX II1G Ex ia IIC T6
ATEX II2G Ex d IIC T6
ATEX II3G Ex nA IIC T6 Gc
ATEX II3G Ex ic IIC T6 Gc
ATEX IECEx II2D Ex tb IIIC Db
ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC
ATEX Ex d, Ex ia
FM XP, NI, DIP I,II,III/1+2/A-G
CSA XP, NI, DIP I,II,III/1+2/A-G
FM XP, DIP, IS, NI I,II,III/1+2/A-G
CSA XP, DIP, IS, NI I,II,III/1+2/A-G
FM+CSA XP,DIP, IS, NI I,II,III/1+2/A-G
CSA General Purpose
IECEx Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga, Ex ia IIIC Db
IECEx Ex d IIC T6 Gb
IECEx Ex ia, Ex d
NEPSI Ex ia IIC T4-T6
NEPSI Ex nA II T4-T6
NEPSI Ex d IIC T4-T6
marine approval only for HART-protocol
SIL2/3 only for HART-protocol
EAC Ex ia IIC T6 Ga
EAC Ex d IIC T6 Gb
UK II3G Ex nA T6 IIC Gc
INMETRO Ex db IIC T6 Gb, Ex tb IIIC Db
INMETRO Ex ia IIC T6 Ga
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX350/370, field communicator 475 or remotely via PC FOUNDATION Fieldbus™ ITK 6.1.2PROFIBUS® PA Profile 3.02 Optional: stainless steel housing for hygienic or Ex d application
Benefits
High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronicsBacklit display with large measured value, bar graph and status condition indicationDiagnostics information according to NAMUR NE107International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approvalSIL certification as per IEC 61508:2010Galvanic isolation 2 kV (sensor input / current output)
iTHERM MultiSens Flex TMS01 Multipoint RTD/TC thermometer
Modular direct contact TC and RTD multipoint thermometer for oil, gas and petrochemical applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
easy-to-use
suitable for hazardous areas
flanged process connection
light chemical processes
3D sensors distributions
modular design
replaceable sensors during shutdown -
Thermowell / protection tube
without (for direct contact sensors type)
with (for replaceable sensors)
with (for increased mechanical protection)
Multi-thermowells, each one dedicated to a sensor -
Insert / probe
mineral insulated (MI), flexible
mineral insulated (MI), flexible, with its own thermowell -
Outer diameter protection tube / Insert
6,0 mm (0,24”)
8,0 mm (0,31″)
10,29 mm (1/8″) -
Max. immersion length on request
up to 30.000,00 mm (1181”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4435 (316L)
1.4541 (321)
1.4550 (347)
Alloy 600 (2.4816) -
Process connection
flange:
2″ ASME/ANSI B16.5 150
…600
3″ ASME/ANSI B16.5 150
..600
4″ ASME/ANSI B16.5 150
…600
6″ ASME/ANSI B16.5 150
…600
8″ ASME/ANSI B16.5 150
…600
DN80 EN/DIN 1092.1 PN10
…PN100
DN100 EN/DIN 1092.1 PN10
…PN100
DN125 EN/DIN 1092.1 PN10
…PN100
DN150 EN/DIN 1092.1 PN10
…PN100
DN200 EN/DIN 1092.1 PN10
…PN100 -
Tip shape
straight
-
Operating temperature range
Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 920 °C
(max. 1.688 °F)
Type N:
max. 1.150 °C
(max. 2.102 °F)
Type T:
max. 370 °C
(max. 698 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1450 psi)
-
Accuracy
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1 -
Response time
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX
IECEX -
Certification
SIL (transmitter only)
Field of application
By complying with the highest safety standards, iTHERM TMS01 can be customized for various applications. Bendable into a 3D layout, it provides a complete temperature profile just by using one nozzle. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available either with TC or RTD technology or with our iTHERM StrongSens.
Petrochemical industryOil & Gas industryHeavy Chemical processes
Benefits
Easy-to-use device with modular and flexible design, ready to be installed either for direct contact measurements or by means of sensor-dedicated protecting tubes. The device can also be installed in thermowells already in place Infinite layouts of 3D sensors distribution for any desired process monitoring configuration High degree of customization thanks to a modular product design for easy installation, process integration and maintenance High degree of insert process compatibility as per standard IEC 60584, ASTM E230 and IEC 60751 On-board electronic heat protection for highest product durability Compliance to different types of protection for use in hazardous locations for easy process integration
TMR31 Compact thermometer
Compact, fast and precise for the measurement of process temperatures in common industries
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
compact temperature probe
fast response time
threaded process connection
with or without neck -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
pipe version, isolated wires, not flexible
-
Outer diameter protection tube / Insert
4,00 mm (0,16″)
6,00 mm (0,24”) -
Max. immersion length on request
up to 600,00 mm (23,62”)
-
Material protection tube/ thermowell
1.4404 (316L)
-
Process connection
male thread:
G1/4″
G1/2″
NPT1/4″
NPT1/2″
M14x1.5
M18x1.5
BSPT R1/2″ -
Tip shape
straight
-
Surface roughness Ra
0,8 μm (32 μin.)
-
Operating temperature range
PT 100:
-50 °C …200 °C
(-58 °F …392 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
-
Accuracy
class A acc. to IEC 60751
-
Response time
t50 = 1 s
t90 = 2 s -
Integration head transmitter
no (4…20mA Signal)
-
Certification
Marine approval
UL 3111-1
Field of application
With cost efficiency, optimal use of space, reliable operation, easy installation and commissioning the TMR31 fulfills the requirements of modern process measurement technology. Vibration-proof integrated thin-film sensors guarantee highest operational safety at the fastest response times.
The TMR31 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR31 with process connections for general applications.
Benefits
Small, compact design made entirely of stainless steelExtremely short response timesHighly accurate even with short insertion lengths4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA outputConfiguration and visualization with ReadWin® 2000 PC operating software, which is free of chargeBreakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43Marine approval
Sanitary digital thermometer iTHERM TM411
Hygienic temperature measurement instrument for optimum product quality, process safety and efficiency
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
hygienic process connections
with neck
suitable for hazardous areas
incl. protection tube
QuickSens for fastest response time
StrongSens for most robust design
QuickNeck for easy and cost saving recalibration -
Thermowell / protection tube
without
incl. thermowell
incl. Tee-/elbow thermowell -
Insert / probe
mineral insulated (MI), flexible
pipe version, isolated wires, not flexible -
Outer diameter protection tube / Insert
6,0 mm (0,24″)
9,0 mm (0,35″)
12,7 mm (0,5″) -
Material protection tube/ thermowell
1.4435 delta-ferrit < 1%
316L -
Process connection
compression fitting
weld in adapter
clamp connections acc. to ISO2852
screwed pipe joint acc. to DIN 11851
aseptic screwed pipe joint acc. to DIN 11864-1
metallic sealing system
thread acc. to ISO 228 for liquiphant adaptor
APV Inline
Varivent
Ingold
SMS 1147
Neumo Biocontrol
T- and elbow thermowell -
Tip shape
straight
reduced
tapered -
Surface roughness Ra
0,76 μm (29,92 μin)
0,38 μm (14,96 μin)
0,38 μm (14,96 μin) electropolished -
Operating temperature range
PT100:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II
ATEX IECEx
FM
CSA
CRN
JPN
JPN Ex ia -
Certification
SIL (transmitter only)
Field of application
The modular sanitary thermometer iTHERM TM411 with digital display delivers highly accurate, reliable and fast temperature measurements in process lines, vessels, tanks, fermenters and more. The high-performance device is designed for the strictly regulated food and life sciences industries. Configure your hygienic instruments from a selection of thin film RTDs with QuickSens or StrongSens technology or 2x Pt100 wire wound temperature sensors, smart transmitters and hygienic process connections.
Designed for use in hygienic and aseptic applications in food, beverage and life sciencesMeasuring range: –200 to 600 °C (-28 to 1 112 °F)Pressure range up to 40 bar (580 psi) Protection class: up to IP69KRemote parametrization with secure Bluetooth® temperature transmittersInternational approvals: Certified for use in hazardous areas, explosion protection as per ATEX/IECEx, CSA, FM, EAC Ex, JPN Ex, NEPSI; Hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Benefits
Optimum process control: Fast sensor response times with iTHERM QuickSens technology (t90: 1.5 s)Up to 75% faster and safer recalibrations with iTHERM QuickNeck – tool-free quick-release for instant insert removalHigh sensor availability under rough conditions: Vibration resistant RTD technology iTHERM StrongSens (> 60g)Easy product selection, configuration and maintenanceIncrease productivity and product safety in sanitary applications with highly accurate and reliable measurementsThermowells, hygienic process connections and housings expertly manufactured from high-grade materials treated for low surface roughness
Sanitary RTD – iTHERM TrustSens TM371
Self-calibrating hygienic temperature transmitter lowers risk and drives automation in regulated processes
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
self-calibrating
metric style
compact temperature probe
hygienic design
life sciences, food & beverage -
Thermowell / protection tube
without
incl. thermowell
incl. Tee-/elbow thermowell -
Insert / probe
without exchangeable insert
-
Outer diameter protection tube / Insert
6.0 mm (0.24”)
9.0 mm (0.35”)
12.7 mm (0.5″) -
Max. immersion length on request
up to 900.00 mm (35.4”)
-
Material protection tube/ thermowell
1.4435 Delta Ferrite < 1%
316L -
Process connection
compression fitting
weld in adapter
clamp connections acc. to ISO 2852
screwed pipe joint acc. to DIN 11851
aseptic screwed pipe joint acc. to DIN 11864-1
metallic sealing system
thread acc. to ISO 228 for Liquiphant adaptor
APV Inline
Varivent
Ingold
SMS 1147
Neumo Biocontrol
TT411 elbow thermowell DIN 11865 -
Tip shape
straight
reduced -
Surface roughness Ra
0.76 μm (29.92 μin)
0.38 μm (14.96 μin)
0.38 μm (14.96 μin) electropolished -
Operating temperature range
Pt100:
-40 °C to 160 °C (-40 °F to 320 °F),
optional up to 190 °C (374 °F)
reference point for automated calibration -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Response time
t50 = 2.5 s
t90 = 5.4 s -
Integration head transmitter
no (4 to 20 mA signal, HART)
-
Ex – approvals
CSA C/US IS, I/1+2/A-F
CSA C/US General Purpose
UK II1/2G Ex ia IIC T6 Ga/Gb, II1/2D Ex ia IIIC Da/Db
ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb, II1/2D Ex ia IIIC T6 Da/Db
Field of application
Our award-winning iTHERM TrustSens TM371 sanitary RTD features the world’s first self-calibrating Pt100 sensor unit! The hygienic temperature transmitter with Heartbeat Technology effectively eliminates the risk of undetected non-conformities, reduces production downtime while increasing product safety and process efficiency in food, beverage and life sciences applications. The instrument complies with FDA and GMP regulations and integrates with the Netilion cloud-based Industry 4.0 ecosystem.
Designed for critical hygienic / aseptic applications in life sciences, fo
iTHERM CompactLine TM311 – Pt100 temperature sensor
Compact, accurate and fast RTD sensor with IO-Link for sterile applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric and imperial style
compact temperature probe
fast response time
high accuracy
standard and hygienic design
hygienic process connection
threaded process connection -
Thermowell / protection tube
without
incl. thermowell
incl. Tee-/elbow thermowell -
Insert / probe
pipe version, isolated wires, not flexible
-
Outer diameter protection tube / Insert
3,0 mm (0,12”)
6,0 mm (0,24”) -
Max. immersion length on request
up to 600,00 mm (23,62”)
-
Material protection tube/ thermowell
1.4435 Delta-Ferrit < 1%
316L -
Process connection
compression fitting
Thread
weld in adapter
clamp connections acc. to ISO2852
screwed pipe joint acc. to DIN 11851
aseptic screwed pipe joint acc. to DIN 11864-1
metallic sealing system
thread acc. to ISO 228 for liquiphant adaptor
Varivent
SMS 1147
Tee-/elbow thermowell -
Tip shape
straight
reduced -
Surface roughness Ra
0,76 μm (29,92 μin)
0,38 μm (14,96 μin)
0,38 μm (14,96 μin) electropolished -
Operating temperature range
PT 100:
-50 °C …200 °C
(-58 °F …392 °F) -
Max. process pressure (static)
at 20 °C: 50 bar (725 psi)
-
Accuracy
class A acc. to IEC 60751
-
Response time
t50 = 1 s
t90 = 1.5 s -
Integration head transmitter
no (4…20mA Signal, IO-Link)
-
Certification
3A, EHEDG, ASME BPE, FDA, TSE
1935/2004, 2023/2006, 10/2011
DNVGL, BV
CSA C/US General Purpose
RCM
Field of application
iTHERM CompactLine TM311 sanitary thermometer provides accurate and fast process temperature measurements in hygienic and aseptic applications. Its temperature sensor offers a 4-wire connection or feeds into a smart temperature transmitter with 4 to 20 mA, IO-Link (auto-detect) or switch output. Featuring TipSens technology, the RTD (Pt100; Class A) delivers response times as low as 1.5 s (t90) for optimum process control. This versatile device is a great choice to drive plant standardization.
Developed for universal use in sterile applicationsHigh standardization potential for skid builders, machine and plant manufacturersMeasuring range: -50 to 200 °C (-58 to 392 °F)Pressure range: Up to 50 bar (725 psi)Protection class: IP69Output: Pt100 (4-wire connection); IO-Link, 4 to 20 mA, 1x PNP switchInternational approvals: 3-A, EHEDG, ASME BPE, FDA, EC 1935/2004, EN 2023/2006, TSE/ADI, GB4806-2016, GB9685-2016; Marine approval acc. to DNV GL
Benefits
Fast installation and easy commissioning:- Compact dimensions for installation in tight spaces- Standard M12 connector with IP69 for easy electrical connection- Recommended process immersion lengths for optimum measurement- Preset temperature rangeExcellent temperature measurement performance:- Short response times as low as 1.5 s (t90)- High sensor accuracy even with short immersion lengths- Improved measuring accuracy with transmitter-sensor matchingSafe and reliable operation:- Device safety to EN 610101-1 and CSA C/US- Electromagnetic compatibility (NAMUR NE 21)- Device diagnostic information (NAMUR NE 43)- Hygienic design manufactured from high-grade stainless steel- Marine approval
iTHERM ModuLine TM151
Trend-setting, highly modular and robust RTD or TC thermometer for a wide range of industrial applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
suitable for high process pressures
with neck or QuickNeck
incl. thermowell / protection tube (metal) or to be installed into thermowell
can be used with StrongSens -
Thermowell / protection tube
barstock (drilled) or to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
16 mm (0,63″)
18 mm (0,71″)
19 mm (0,75″)
19,5 mm (0,77″)
20 mm (0,79″)
22,2 mm (0,87″)
24 mm (0,95″)
25 mm (0,98″)
25,4 mm (1,0″)
26 mm (1,02″)
27 mm (1,06″)
30 mm (1,18″)
33,4 mm (1,31″) -
Max. immersion length on request
up to 1.500,0 mm (59,06”)
-
Material protection tube/ thermowell
316 (1.4401)
316L (1.4404)
316/316L (1.4401/1.4404)
316Ti (1.4571)
347 (1.4550)
310 (1.4841)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
10CrMo9-10 (1.7380)
13CrMo4-5 (1.7335)
16Mo3 (1.5415)
A105 (1.0460)
C22.8 (P250GH) (1.0460)
P355NH (1.0565)
Duplex S32205 (1.4462)
Titanium Gr2 (3.7035) -
Process connection
Male thread:
G1″
NPT1/2″, NPT3/4″, NPT 1″
M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
Female thread:
M24x1.5
NPT1/2″
Flange:
DN25 PN16, PN40, PN50, PN100 B1
DN40 PN40 B1
DN50 PN40, PN63 B1
ASME 1″ 150 RF
ASME 1″ 300 RF
ASME 1″ 600 RF
ASME 1″ 900/1500 RF
ASME 1 1/2″ 150 RF
ASME 1 1/2″ 300 RF
ASME 1 1/2″ 600 RF
ASME 1 1/2″ 900/1500 RF
ASME 1 1/2″ 2500 RF
ASME 2″ 150 RF
ASME 2″ 300 RF
ASME 2″ 600 RF
ASME 2″ 900/1500 RF
ASME 2″ 2500 RF
to weld-in:
Diameter 18 mm (0,71″)
Diameter 24 mm (0,94″)
Diameter 26 mm (1,02″)
Diameter 26,7 mm (NPS 3/4″)
Diameter 33,4 mm (NPS 1″) -
Tip shape
straight
tapered
stepped -
Surface roughness Ra
0,76 μm (30 μin.)
1,6 μm (63,0 μin.) -
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration up to 500 bar
-
Accuracy
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX II3G Ex ec IIC T6, II3D
CSA C/US General Purpose
CSA C/US IS, NI I/1+2/A-D
CSA C/US XP, NI, DIP I, II, III/1+2/A-G
CSA C/US DIP II, III / 1/E-G
EAC 0Ex ia IIC T6…T1 Ga X
EAC Ga/Gb Ex d IIC T6…T1 X
EAC Ex ta/tb IIIC 85oC…450oC Da/Db X
EAC Ga/Gb Ex ia IIC T6…T1 X
EAC 0Ex ia IIC T6…T1 Ga X, Ex ia IIIC 85oC…450oC Da/Db X
EAC Ga/Gb Ex d IIC T6…T1 X, Ex ta/tb IIIC 85oC…450oC Da/Db X
INMETRO Ex ia IIC T6 Ga/Gb, Ex ia IIIC Da/Db
INMETRO Ex d IIC T6 Ga/Gb, Ex tb IIIC Da/Db
INMETRO Ex nA IIC T6 Gc
CCC Ex ia II
iTHERM ModuLine TM111
Trend-setting, modular temperature sensor for direct installation without thermowell, designed for a wide range of industrial applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
metric style
universal range of application
suitable for hazardous areas
can be used with StrongSens, QuickSens insert
direct process contact -
Thermowell / protection tube
without, direct process contact
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
Insert:
3,0 mm
6,0 mm -
Max. immersion length on request
up to 4.500,0 mm (177”)
-
Material protection tube/ thermowell
Insert Material:
316L (1.4404)
Alloy 600 (2.4816)
Pyrosil -
Process connection
Thread:
G1/4, G1/2″
NPT1/2″, NPT3/4″
M18x1.5, M20x1.5
Cap-nut:
G1/2″, G3/4″
Compression fitting, also spring load:
NPT1/2″, G1/2″
Weld-in adapter cylindrical or spherical -
Tip shape
straight
-
Surface roughness Ra
< 1.6 μm (63.00 μin)
-
Operating temperature range
PT100 TF StrongSens:
-50 °C …500 °C
(-58 °F …932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C …600 °C
(-328 °F …1.112 °F)
PT100 TF:
-50 °C …400 °C
(-58 °F …752 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Typ J:
max. 800 °C
(max. 1.472 °F)
Typ N:
max. 1.100 °C
(max. 2.012 °F) -
Max. process pressure (static)
depending on the configuration
-
Accuracy
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
t90 starting at < 1,5 s QuickSens
depending on configuration -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
ATEX
ATEX IECEx
NEPSI
IECEx
EAC Ex
CSA C/US
INMETRO -
Certification
SIL (Transmitter)
Field of application
Our explosion-proof temperature sensor iTHERM ModuLine TM111 is ideal for a wide range of industrial applications and hazardous areas. Easy-to-use metric version with outstanding RTD or TC sensor technology. An optional head transmitter, with all common communication protocols – Bluetooth® technology for high measurement accuracy and reliability. It features vibration-resistant and fast-response sensor technology (iTHERM StrongSens and QuickSens).
Universal range of applicationMeasuring range: –200 to +1.100 °C (–328 to +2.012 °F)Pressure range up to 75 bar (1088 psi)Degree of protection: up to IP 68Vibration-resistant sensor elements up to 60g
Benefits
User-friendly and reliable from product selection to maintenance iTHERM inserts: globally unique, automated production. Full traceability and consistently high product quality for reliable measured valuesiTHERM QuickSens: fastest response times 1.5 s for optimum process control iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety iTHERM TA30x: variety of terminal heads for easier handling and lower installation and maintenance costsInternational certification: explosion protection according to ATEX, IECEx, CSA C US and NEPSI
TH13 Modular RTD thermometer, US style
Best in class temperature measurement technology for general applications
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style
modular temperature assembly
threaded process connection
process connection as weld in version
with extension
incl. thermowell -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
3/4” (19,05 mm)
1” (25,40 mm)
17/16” (26,99 mm)
15,88 mm …33,40 mm
(0,63” …1,31”) -
Max. immersion length on request
up to 24″ (609 mm)
others on request -
Material protection tube/ thermowell
316/316L
A105
AlloyC276
others on request -
Optional coating
Available on request
-
Process connection
male thread:
NPT1/2″
NPT3/4″
NPT1″
weld in version
socket weld version
1″ -
Tip shape
reduced
tapered
straight -
Surface roughness Ra
32 μin (0.80 μm)
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
depends on configuration -
Accuracy
class AA acc. to IEC 60751
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex – approvals
transmitter only
FM IS
CSA IS
FM/CSA IS -
Certification
SIL (transmitter only)
Field of application
The robust device with a barstock thermowell is a complete unit ready for use with various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of process connections, dimensions, and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
The TH13 temperature sensors are RTD assemblies installed in thermowells and designed for use in all types of process industries, including heavy industries, due to their rugged design.The sensor is made up of a measurement probe with an insulated RTD element, sheath and a thermowell made of barstock material. The sensor assemblies can be used in process industries such as:ChemicalsPetrochemical Power plants Refineries Offshore platforms
Benefits
High flexibility due to modular assembly with standard terminal heads and customized immersion lengthOne Source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications. Remove and install straight out of the box!Improved galvanic isolation on most devices (2 kV)Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a complete point solutionAll iTEMP® transmitters provide long term stability ≤ 0.05 % per yearFast response time with reduced/tapered tip formHead transmitter with easy selection: Analog output 4 to 20 mA, HART®, PROFIBUS® PA or FOUNDATION Fieldbus™
High-Temperature Thermocouple – TAF16
Designed for the extremely high process temperatures in cement production, steel treatment, incinerators and fluidized bed furnaces
-
Measuring principle
Thermocouple
-
Characteristic / Application
metric style
modular temperature assembly
high temperature probe (furnace)
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
welded protection tube
ceramic protection tube -
Insert / probe
mineral insulated (MI), flexible
ceramic capilarry, rigid -
Outer diameter protection tube / Insert
14,0 mm (0,55″)
15,0 mm (0,59″)
17,2 mm (0,68″)
18,0 mm (0,71″)
21,3 mm (0,84″)
22,0 mm (0,87″)
26,7 mm (1,05″)
28,0 mm (1,10″) -
Max. immersion length on request
up to 4.525,00 mm (178,15”)
-
Material protection tube/ thermowell
1.4401 (316)
1.4749 (~446)
1.4841 (310)
Alloy 600 (2.4816)
Alloy 601 (2.4851)
Incoloy 800HT (1.4959)
Kanthal AF
Kanthal Super
NiCo
Siliciumnitrid(SiN) -
Process connection
compression fitting:
G1/2″
G3/4″
G1″
G11/4″
G11/2″
adjustable Flange -
Tip shape
straight
-
Operating temperature range
Type K:
-40 °C …1.100 °C
(-40 °F …2.012 °F)
Type J:
-40 °C …750 °C
(-40 °F …1.382 °F)
Type N:
-40 °C …1.150 °C
(-40 °F …2102 °F)
Type S:
0 °C …1.400 °C
(32 °F …2.552 °F) -
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
-
Accuracy
class 2 acc. to IEC 60584
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Certification
SIL (transmitter only)
Field of application
Measuring points with extremely high process temperatures require this high-temperature thermometer with a ceramic or metal thermowell as well as thermocouples made from special metals such as platinum and rhodium. The thermowell made from special materials protects from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.
Applicable for temperature measurement in cement production, steel treatment, incinerators and fluidized bed furnaces. The TAF16 contains a single or double thermocouple insert and a metal or ceramic protection tube as well as an optional internal sheathProcess temperatures: up to +1,700 °C (+3,092 °F)
Benefits
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistanceLong-term stable measurement due to sensor protection with non-porous materialsFlexible product selection thanks to modular designOptimized life cycle costs by means of replaceable spare parts

































