The standard sensor for highest demands for level measurement in bulk solids
Economically efficient basis model for all level applications in bulk solids
The Multiparameter device is the innovation in interface measurement
For high temperature and high pressure applications in the oil & gas, chemical and power industry
For the highest hygiene requirements in the food and life sciences industry
Coated probe for use in aggressive liquids
The standard sensor for highest demands in liquid level measurement
For all basic level applications in liquids
Compact transmitter for point level detection, continuous level, interface and density measurement
Electronic differential pressure system utilizing two metal sensor modules and one transmitter
Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter
Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m)
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m)
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 20m)
Hygienic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 3m)
Hygienic Memosens sensor for turbidity measurement in drinking water, process water and utilities
Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production
Memosens 2.0 combined electrode for chemical processes and poisoning media
Memosens 2.0 pH electrode for chemical processes and poisoning media
Memosens 2.0 ORP electrode for the chemical and life sciences industries
Memosens 2.0 glass sensor for the food & beverage industry and for bioreactors in biotech industry
Memosens glass electrode for bioreactors in the biotech industry and for the food industry
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
Memosens Wave spectrometer for color measurement in the Food & Beverage, Chemical and Life Sciences industries
Memosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)
Fully automatic system for pH and ORP measuring points in all industries
Memosens sensor for drinking water, pool and process water as well as utilities in all industries
Memosens sensor for water, process water and utilities in all industries
Colorimetric system for wastewater monitoring and optimization of process control
Analyzer for chemical oxygen demand in environmental monitoring, industrial and municipal wastewater

Guided radar measurement Time-of-Flight Levelflex FMP57

The standard sensor for highest demands for level measurement in bulk solids

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device for pulling forces up to 30kN
    Rod probe, Rope probe
    Integrated data memory. Factory precalibrated, Reliable measuring: in dusty atmosphere, in high + narrow silos, in vessels + obstacles.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus),
    4-wire (HART),
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe: +/- 2 mm (0.08 in)
    Rope probe <= 15 m (49ft):
    +/- 2 mm (0.08 in)
    Rope probe > 15 m (49ft):
    +/- 10 mm (0,39 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+150 °C
    (-40…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar
    (Vacuum…232 psi)

  • Main wetted parts

    Rod probe:
    316Ti, 316L, PEEK, PPS
    Rope probe:
    304, 316, 316Ti, 316L, PEEK, PPS, PA

  • Process connection

    Thread:
    G1 1/2, MNPT1 1/2
    Flange:
    ASME 1 1/2″…8″,
    DN50…DN200,
    JIS 10K

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 45 m (148 ft)

  • Max. measurement distance

    Rod:
    4 m (13 ft) Min DK>1.4
    Rope:
    20 m…25 m (66 ft…82 ft) Min DK >1.4;
    25 m…30 m (82ft…98 ft) Min DK >1.6;
    30 m…45 m (98ft…148 ft) Min DK>1,9

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV/ KR

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

Field of application
Levelflex FMP57 is the sensor for the highest demands in bulk solids and best suited for measurements in high silos, bunkers or stockpiles. Providing rope probes up to a length of 45m the FMP57 is also suited to measurements in high silos. Levelflex FMP57 guided radar is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.

Version with rod or rope probe.
Process connections: Thread or flange
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, SIL, marine approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP56

Economically efficient basis model for all level applications in bulk solids

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Basic device for pulling forces up to 12 kN
    Rope probe
    Integrated data memory, Factory precalibrated, Reliable measuring: in dusty atmosphere, in high + narrow silos, in vessels + obstacles.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus),
    4-wire (HART),
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rope probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    –40…+120 °C
    (–40…+248 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar
    (Vacuum…232 psi)

  • Main wetted parts

    Rope probe:
    304, 316, 316Ti, 316L, PEEK, PPS, PA

  • Process connection

    Thread:
    G 3/4, MNPT 3/4

  • Sensor length

    Rope probe: 12 m (40 ft)

  • Max. measurement distance

    Rope: 12 m (40 ft)
    Min DK >1.4

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    SIL

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

Field of application
Levelflex FMP56 is particularly designed for light-duty process conditions as they occur in silos and storage tanks for solids. FMP56 guided radar offers maximum reliability even in case of dusty atmosphere in narrow silos or in vessels with obstacles. Levelflex FMP56 is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement. Remote access with SmartBlue app via Bluetooth module is available.

Version with rope probe.
Process connections: Thread or adapter flange
Temperature: -40 to +120°C (-40 to +248°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: 12m (39ft)
Accuracy: ± 2mm (0.08″)
International explosion protection certificates, SIL, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP55

The Multiparameter device is the innovation in interface measurement

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device Multiparameter (capacitance and guided radar)
    Rod probe, Rope probe, Coaxial probe
    Integrated data memory, Factory precalibrated, Reliable measuring: for interface with emulsion, in case of moved surface + foam, for changing medias.

  • Interface measurement

    Interfaces liquid / liquid also with emulsion layers;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe :
    +/- 2 mm (0.08 in)
    Rope probe:
    +/- 2 mm (0.08 in)
    Coaxial probe:
    +/- 2 mm (0.08 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+200 °C
    (-40…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    Rod probe:
    316L, PTFE, PFA
    Rope probe:
    316, 316L, PTFE, PFA
    Coaxial probe:
    316L, PTFE, PFA

  • Process connection

    Flange:
    ASME 1 1/2″…6″,
    DN50…DN150,
    JIS 10K

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 10 m (33 ft)
    Coaxial probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 4 m (13 ft)
    Min DK >1.4
    Rope: 10 m (33 ft)
    Min DK >1.4
    Coaxial: 6 m (20 ft)
    Min DK >1.4

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.1, B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV/ KR

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

Field of application
Levelflex FMP55 guided radar with SensorFusion offers the worldwide first combination of the capacitance and guided radar measuring principle in one device. The instrument guarantees safe measured value acquisition even in emulsion layers and issues level and interface layer signals simultaneously. This makes the FMP55 Multiparameter the new standard in interface measurement especially in the oil & gas, chemical and petrochemical industry.

Version with rod, rope or coax probe.
Process connections: Thread or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13t), rope 10m (33ft), coax 6m (20ft)
Accuracy: Rod ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)Worlds easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP54

For high temperature and high pressure applications in the oil & gas, chemical and power industry

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device high pressure/ high temperature
    Rod probe, Rope probe, Coaxial Probe
    Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias

  • Interface measurement

    Clean interfaces liquid/ liquid;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe: +/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft):
    +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft):
    +/- 10 mm (0.39 in)
    Coaxial probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -50…+80 °C
    (-58…+176 °F)

  • Process temperature

    XT: -196…+280 °C
    (-321…+536 °F)
    HT: -196…+450 °C
    (-321…+842 °F)

  • Process pressure / max. overpressure limit

    Vacuum…400 bar
    (Vacuum…5800 psi)

  • Main wetted parts

    Rod probe:
    304, 316L, Alloy C, Ceramic
    Rope probe:
    304, 316, 316L, Alloy C, Ceramic
    Coaxial probe:
    304, 316L, Alloy C, Ceramic

  • Process connection

    Thread:
    G 1 1/2, MNPT 1 1/2
    Flange:
    ASME 2″…4″,
    DN50…DN100,
    JIS 10K, 63K,
    Fisher
    Masoneilan

  • Sensor length

    Rod probe: 10 m (33 ft)
    Rope probe: 45 m (148 ft)
    Coaxial probe: 6 m (20 ft)

  • Max. measurement distance

    Rod:
    10 m (33 ft) Min DK>1.6
    Rope:
    25 m…30 m (82 ft…98 ft) Min DK>1.6;
    30 m…45 m (98 ft…148 ft) Min DK >1,9
    Coaxial probe: 6 m (20 ft) Min DK>1.4

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.1, B31.3
    AD2000
    Steam boiler approval

  • Marine approval

    GL/ DNV/ ABS/ LR/ BV

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.

Version with rod, rope or coax probe.
Process connections: Thread or flange
Temperature: -196 to +450°C (-320 to +842°F)
Pressure: -1 to +400bar (-14.5 to +5,800psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: rod ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, steam boiler approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP53

For the highest hygiene requirements in the food and life sciences industry

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device. Hygiene
    Rod probe,
    ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe:+/- 2 mm (0.08 in)

  • Ambient temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process temperature

    -20…+150 °C
    (-4…+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum…16 bar
    (Vacuum…232 psi)

  • Main wetted parts

    Rod probe:
    304, 304L, 316L, PEEK

  • Process connection

    Thread:
    M24

  • Process connection hygienic

    Tri-Clamp
    DIN11851
    DIN11864-1
    NEUMO
    Varivent N
    SMS

  • Sensor length

    Rod probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 6 m (20 ft)
    Min DK>1.6

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A, EHEDG
    CoC ASME-BPE

  • Options

    Sensor remote with 3 m/9 ft or 6 m/18 ft cable,
    Weld-in adpater,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.

Version with rod probe.

Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO, Varivent N, SMS)
Temperature: -20 to +150°C (-4 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 6m (20ft)
Accuracy: ±2mm (0.12″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP52

Coated probe for use in aggressive liquids

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device coated for corrosive media
    Rod probe, Rope probe
    Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.

  • Interface measurement

    Clean interfaces liquid/ liquid;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe :+/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft):
    +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft):
    +/- 10 mm (0.39 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -50…+200 °C
    (-58…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    Rod probe:
    304, 304L, 316L, PTFE, PFA
    Rope probe:
    304, 304L, 316, 316L, PTFE, PFA

  • Process connection

    Flange:
    ASME 1 1/2″…6″,
    DN50…DN100,
    JIS 10K

  • Process connection hygienic

    Tri-Clamp
    DIN11851

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 45 m (148 ft)

  • Max. measurement distance

    Rod:
    4 m (13 ft) Min DK>1.6
    Rope:
    25 m…30 m (82 ft…98 ft) Min DK>1.6;
    30 m…45 m (98 ft…148 ft) Min DK>1,9

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    ASME B31.1, B31.3
    AD2000

  • Hygienic approvals

    3A, EHEDG

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Gas-tight feed through,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod or rope probe.

Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP51

The standard sensor for highest demands in liquid level measurement

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Premium device
    Rod probe, Rope probe, Coaxial probe
    Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.

  • Interface measurement

    Clean interfaces liquid/ liquid;
    Simultaneous measurement of interface and overall level

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe :+/- 2 mm (0.08 in)
    Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
    Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
    Coaxial probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -50…+80 °C
    (-58…+176 °F)

  • Process temperature

    -50…+200 °C
    (-58…+392 °F)

  • Process pressure / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Main wetted parts

    Rod probe:
    316L, Alloy C, Ceramic
    Rope probe:
    316, 316L, Alloy C, Ceramic
    Coaxial probe:
    316L, Alloy C, Ceramic, PFA

  • Process connection

    Thread:
    G3/4…G1 1/2;
    MNPT 3/4…MNPT1 1/2
    Flange:
    ASME 1 1/2″…8″,
    DN50…DN 200,
    JIS 10K

  • Sensor length

    Rod probe: 10 m (33 ft)
    Rope probe: 45 m (148 ft)
    Coaxial probe: 6 m (20 ft)

  • Max. measurement distance

    Rod: 10 m (33 ft) Min DK>1.6
    Rope: 25 m…30 m (82ft…98 ft) Min DK>1.6;
    30m…45 m (98ft…148 ft) Min DK>1,9
    Coaxial probe: 6 m (20 ft) Min DK>1.4

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.1, B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Gas-tight feed through,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP51 for level measurement even under extreme process conditions like high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod, rope or coax probe.

Process connections: Threads or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Guided radar measurement Time-of-Flight Levelflex FMP50

For all basic level applications in liquids

  • Measuring principle

    Guided radar

  • Characteristic / Application

    Basic device
    Rod probe, Rope probe
    Integrated data memory, Factory precalibrated, Reliable measuring for changing medias.

  • Specialities

    Heartbeat Technology,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    HistoROM,
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
    4-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Accuracy

    Rod probe: +/- 2 mm (0.08 in)
    Rope probe: +/- 2 mm (0.08 in)

  • Ambient temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process temperature

    -20…+80 °C
    (-4…+176 °F)

  • Process pressure / max. overpressure limit

    Vacuum…6 bar,
    (Vacuum…87 psi)

  • Main wetted parts

    Rod probe: 316L, PPS, Viton
    Rope probe: 316, PPS, Viton

  • Process connection

    Thread:
    G 3/4, MNPT 3/4
    Flange:
    UNI Flange

  • Sensor length

    Rod probe: 4 m (13 ft)
    Rope probe: 12 m (40 ft)

  • Max. measurement distance

    Rod: 4 m (13 ft) Min DK>1.6
    Rope: 12 m (40 ft) Min DK>1.6

  • Communication

    4…20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL

  • Design approvals

    EN 10204-3.1

  • Options

    Sensor remote with 3 m/ 9 ft cable,
    Remote operation via SmartBlue App using Bluetooth®

  • Application limits

    Application limits

Field of application
Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Version with rod or rope probe.
Process connections: Thread or adapter flange
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +87psi)
Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs

Radiometric level and density measurement Gammapilot FMG50

Compact transmitter for point level detection, continuous level, interface and density measurement

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Compact transmitter for extreme process conditions (temperature, pressure);
    Non-contact measuring technique

  • Interface measurement

    Interfaces liquid / liquid also with emulsion layers
    Interfaces liquid / solid

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning, operation and maintenance with the SmartBlue App

  • Supply / Communication

    2-wire loop powered

  • Accuracy

    +/-1%

  • Ambient temperature

    -40 °C…+80 °C,
    (-40 °F…+176 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Sensor length

    PVT scintillator
    400 mm…3000 mm,
    >3000 mm cascade mode

  • Max. measurement distance

    Unlimited measuring range,
    Cascade

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex

  • Safety approvals

    Overfill protection WHG
    SIL 2/3

  • Design approvals

    EN 10204-3.1

  • Options

    Display

  • Components

    Isotope: FSG60, FSG61,
    Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
    Mounting accessories: FHG61

  • Measuring principle

    Radiometric

  • Characteristic / Application

    Compact transmitter for extreme process conditions (temperature, pressure);
    Non-contact measuring technique

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning, operation and maintenance with the SmartBlue App

  • Supply / Communication

    2-wire loop powered

  • Accuracy

    +/-1%

  • Ambient temperature

    -40 °C…+80 °C,
    (-40 °F…+176 °F)

  • P

Electronic differential pressure Deltabar FMD72

Electronic differential pressure system utilizing two metal sensor modules and one transmitter

  • Measuring principle

    Differential pressure

  • Characteristic

    Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

  • Supply voltage

    4…20 mA HART:
    12…45V DC (Non Ex)
    Ex ia: 12…30V DC

  • Reference Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Long term stability

    0.05% of URL/year of individual sensor

  • Process temperature

    –40…+125°C
    (–40…+257°F)

  • Ambient temperature

    –40…+80°C
    (–40…+176°F)

  • Measuring cell

    400 mbar…10 bar
    (6 psi…150psi)

  • Vacuum resistance

    10 mbar (0.15 psi)

  • Max. overpressure limit

    160 bar (2400 psi)

  • Process connection

    Threads
    Flange (DIN, ASME,JIS)

  • Process connection hygienic

    DIN11851
    DIN11864-1
    Tri-Clamp
    DRD
    Varivent

  • Material process membrane

    316L, AlloyC,

  • Fill fluid

    Silicone oil
    Synthetic oil

  • Material housing

    Die-cast aluminum
    Stainless steel

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

  • Design approvals

    NACE MR0175,
    EN10204-3.1,

  • Hygienic approvals

    EHEDG
    3A

  • Measuring principle

    Differential pressure

  • Characteristic / Application

    Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

  • Supply / Communication

    4…20 mA HART

  • Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Long term stability

    0.05% of URL/year of individual sensor

  • Ambient temperature

    –40…+80°C
    (–40… +176°F)

  • Process temperature

    –40…+125°C
    (–40 … +257°F)

  • Process pressure / max. overpressure limit

    160 bar (2400 psi)

  • Pressure measuring range

    400 mbar…10 bar
    (6 psi…150 psi)

  • Main wetted parts

Electronic differential pressure Deltabar FMD71

Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter

  • Measuring principle

    Differential pressure

  • Characteristic

    Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.

  • Supply voltage

    4…20 mA HART:
    12…45V DC (Non Ex)
    Ex ia: 12…30V DC

  • Reference Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Long term stability

    0.05% of URL/year of individual sensor

  • Process temperature

    –25…+150°C
    (–13…+302°F)

  • Ambient temperature

    –40…+80°C
    (–40…+176°F)

  • Measuring cell

    100 mbar…40 bar
    (1.5 psi…600 psi)

  • Vacuum resistance

    0 mbar

  • Max. Turn down

    100 : 1

  • Max. overpressure limit

    60 bar (900 psi)

  • Process connection

    Threads
    Flansch (DIN, ASME, JIS)

  • Process connection hygienic

    DIN11851
    DIN11864-1
    Tri-Clamp
    DRD
    Varivent

  • Material process membrane

    Ceramic
    316L, AlloyC

  • Material gasket

    Viton, Kalrez, EPDM, NBR, Silicone

  • Fill fluid

    Silicone Oil

  • Material housing

    Die-cast aluminum
    Stainless steel

  • Communication

    4…20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

  • Design approvals

    NACE MR0175,
    EN10204-3.1,

  • Hygienic approvals

    EHEDG,
    3A

  • Measuring principle

    Differential pressure

  • Characteristic / Application

    Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.

  • Supply / Communication

    4…20 mA HART:
    12…45V DC
    Exia: 12…30V DC

  • Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Long term stability

    0.05% of URL/year of individual sensor

  • Ambient temperature

    –40…+80°C
    (–40…+176°F)

  • Process temperature

    –25…+150°C
    (–13…+302°F)

  • Process pressure / max. overpressure limit

Ultrasonic measurement Time-of-Flight Prosonic FDU95

Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C…80 °C
    or 150 °C,
    (-40 °F…176 °F
    or 302 °F)

  • Process temperature

    -40 °C…80 °C
    or 150 °C,
    (-40 °F…176 °F
    or 302 °F)

  • Process pressure / max. overpressure limit

    0.7 bar…1.5 bar abs
    (10 psi…22 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.7 m / 80 °C,
    (2.3 ft / 176 °F),
    0.9 m / 150 °C,
    (2.9 ft / 302 °F)

  • Max. measurement distance

    45 m (148 ft)

  • Communication

    Transmitter:
    4…20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 80 °C
    or 150 °C
    (-40 °F … 176 °F
    or 302 °F)

  • Process temperature

    -40 °C … 80 °C
    or 150 °C
    (-40 °F … 176 °F
    or 302 °F)

  • Process pressure / max. overpressure limit

    0.7 bar…1.5 bar abs
    (10 psi…22 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / PE foam (80°C / 176°F)
    Silicon / stainless steal (150°C / 302°F))

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.7 m / 80 °C
    (2.3 ft / 176 °F)
    0.9 m / 150 °C
    (2.9 ft / 302 °F)

  • Max. measurement distance

    45 m (148 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

  • Components

    Transmitter:
    FMU90

Field of application
The FDU95 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in solids 45m (148ft).

Sensor for continuous, non-contact level measurement of bulk materials in silos, on belts, stockpiles and in crushers. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +80°C or +150°C (-40 to +176°F or +302°F)
Pressure: +0.7 to +1.5bar (+10 to +22psi)
Maximum measuring range: Solids 45m (148ft)
Blocking distance: 0.7m / 80°C (2.3ft), 0.9m / 150°C (2.9ft)
International explosion protection certificates

Benefits
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are presentSuited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)Reduced build-up formation because of the self-cleaning effectIntegrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioningWeather resistant and flood-proof (IP 68)Non-contact measurement method minimizes service requirementsInternational Dust-Ex and Gas-Ex certificates available

Ultrasonic measurement Time-of-Flight Prosonic FDU93

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4…20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 3 bar abs
    (10 psi … 43 psi)

  • Main wetted parts

    UP (unsaturated polyester)
    Silicon / Al PTFE coated

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    Liquids: 25 m (85 ft),
    Solids: 15 m (50 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

  • Components

    Transmitter:
    FMU90

Field of application
The FDU93 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximu

Ultrasonic measurement Time-of-Flight Prosonic FDU92

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 20m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 20 m (65 ft),
    Solids: 10 m (33 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process temperature

    -40 °C … 95 °C
    (-40 °F … 203 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.4 m (1.3 ft)

  • Max. measurement distance

    Liquids: 20 m (65 ft),
    Solids: 10 m (33 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

  • Components

    Transmitter:
    FMU90

  • Measuring principle

    Ultrasonic

  • Product headline

    Version with separate transmitter in field housing or top hat rail housing
    Cost effective solution for open channel flow measurement in water / wastewater plants

  • Max. measurement error

    accuracy:
    distance measurement: +/- 2mm + 0.17%

Ultrasonic measurement Time-of-Flight Prosonic FDU91F

Hygienic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 105 °C
    (-40 °F … 221 °F)

  • Process temperature

    -40 °C … 105 °C
    (-40 °F … 221 °F)
    CIP: 30 min: 135 °C
    (30 min: 275 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    316L (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1″, DN80 / 100, ASME 3″ / 4″

  • Process connection hygienic

    Tri-Clamp ISO2852, DN80 3 1/2″, DN100 4″

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Design approvals

    EN 10204-3.1

  • Hygienic approvals

    3A

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    Foam / high turbulence possible:
    FDU92
    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 105 °C
    (-40 °F … 221 °F)

  • Process temperature

    -40 °C … 105 °C
    (-40 °F … 221 °F)
    30 min: 135 °C / 275 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    316L (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1″, DN80 / 100, ASME 3″ / 4″

  • Process connection hygienic

    Tri-Clamp ISO2852, DN80 (3 1/2″), DN100 (4″)

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certifica

Ultrasonic measurement Time-of-Flight Prosonic FDU91

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA6P)

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20 mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    Foam / high turbulence possible:
    FDU92
    Flange-flush assembly:
    FDU91F
    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART , Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (fully welded IP68 / NEMA 6P)

  • Process connection

    G / NPT 1″

  • Blocking distance

    0.3 m (1 ft)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

  • Components

    Transmitter:
    FMU90

Ultrasonic measurement Time-of-Flight Prosonic FDU90

Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 3m)

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Specialities

    Floating protection tube

  • Supply / Communication

    4-wire (HART, Profibus DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (IP68 / NEMA6P)

  • Process connection

    Front side thread:
    G / NPT 1 1/2″
    Rear side thread:
    G / NPT 1″
    Ceiling mounting

  • Blocking distance

    0.07 m (0.23 ft)

  • Max. measurement distance

    Liquids: 3 m (9.8 ft),
    Solids: 1.2 m (3.9 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

  • Components

    Transmitter:
    FMU90, FMU95

  • Application limits

    Foam / high turbulence possible:
    FDU92
    Flange-flush assembly:
    FDU91F
    For tank farms scanner:
    FMU95

  • Measuring principle

    Ultrasonic

  • Characteristic / Application

    Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter

  • Supply / Communication

    4-wire (HART, PROFIBUS DP)

  • Accuracy

    +/- 2mm + 0.17% of measured distance

  • Ambient temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process temperature

    -40 °C … 80 °C
    (-40 °F … 176 °F)

  • Process pressure / max. overpressure limit

    0.7 bar … 4 bar abs
    (10 psi … 58 psi)

  • Main wetted parts

    PVDF (IP68 / NEMA6P)

  • Process connection

    Front side thread:
    G / NPT 1 1/2″
    Rear side thread:
    G / NPT 1″
    Ceiling mounting

  • Blocking distance

    0.07 m (0.23 ft)

  • Max. measurement distance

    Liquids: 3 m (9.8 ft),
    Solids: 1.2 m (3.9 ft)

  • Communication

    Transmitter:
    4 … 20 mA HART
    Profibus DP

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex

  • Options

    Second 4…20mA output

Turbidity sensor Turbimax CUS52D

Hygienic Memosens sensor for turbidity measurement in drinking water, process water and utilities

  • Measuring principle

    Single beam scattered light

  • Application

    Turbidity measurement in:
    Drinking and process water
    Saline water
    Utilities of all industries

  • Installation

    Inline Insitu, sensor with clamp, flow cell, sensor with clamp, retractables, sensor straight, immersion in open channels

  • Design

    40 mm sensor

  • Dimension

    40 mm design, hygienic Clamp-version
    320 x 40 mm

  • Material

    Stainless steel version: 1.4404
    Plastic version: sensor head: PEEK, shaft: PPS
    Optical windows: sapphire
    O-rings: EPDM

  • Measurement range

    0.000 to 4000 FNU

  • Ingress protection

    IP68

  • Output / communication

    Memosens

  • Measuring principle

    Single beam scattered light

  • Application

    Turbidity measurement in:
    Drinking and process water
    Saline water
    Utilities of all industries

  • Installation

    Inline Insitu, sensor with clamp, flow cell, sensor with clamp, retractables, sensor straight, immersion in open channels

  • Measurement range

    0.000 to 4000 FNU

Digital combined pH/ORP sensor Memosens CPS96E

Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production

  • Measuring principle

    Potentiometric

  • Application

    pH / ORP sensor for heavily contaminated media
    and suspended solids
    • Chemical processes
    • Pulp and paper industry
    • Flue gas cleaning
    • Contaminated media:
    • Solids
    • Emulsions
    • Precipitation reactions

  • Characteristic

    Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

  • Measurement range

    ORP: –1 500 to 1 500 mV
    pH: 0 to 14

  • Measuring principle

    Pt-disc as additional ORP element
    rH measurement and control of the reference impedance

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology
    Hydrolysis stable gel

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B
    Metal lead: Ag/AgCl
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16.57 inch)

  • Process temperature

    0 to 110 °C (32 to 230 °F)

  • Process pressure

    0.8 to 14 bar (11.6 to 203 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Measuring principle

    Sensor ORP / Redox

  • Application

    pH / ORP sensor for heavily contaminated media
    and suspended solids
    • Chemical processes
    • Pulp and paper industry
    • Flue gas cleaning
    • Contaminated media:
    • Solids
    • Emulsions
    • Precipitation reactions

  • Characteristic

    Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications

  • Measurement range

    ORP: –1 500 to 1 500 mV
    pH: 0 to 14

  • Measuring principle

    Pt-disc as additional ORP element
    rH measurement and control of the reference impedance

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology
    Hydrolysis stable gel

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B
    Metal lead: Ag/AgCl
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16.57 inch)

  • Process temperature

    0 to 110 °C (32 to 230 °F)

  • Process pressure

    0.8 to 14 bar (11.6 to 203 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

Field of application
Memosens CPS96E is the specialist for media with a high content of suspended solids such as dispersions, precipitations or emulsions. The open aperture prevents fouling and ensures reliable simultaneous pH and ORP measurement. Thanks to Memosens 2.0 digital technology, CPS96E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Chemical processesPulp and paper industryContaminated media and suspended solids- Dispersions- Precipitations- EmulsionsWith ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and offering a future-proof basis for predictive maintenance and enhanced IIoT services. Simultaneous measurement of pH, ORP and rH values (in rH mode) provides a better process overview for tighter process control. Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality. Rob

Combined pH/ORP sensor Memosens CPS76E

Memosens 2.0 combined electrode for chemical processes and poisoning media

  • Measuring principle

    Potentiometric

  • Application

    Process technology and monitoring of processes with:
    – Rapidly changing pH values
    – High levels of electrode poisons, such as H2S

  • Characteristic

    Digital pH/ORP electrode for chemical process with an ion trap for poison-resistant reference

  • Measurement range

    ORP: –1 500 to 1 500 mV
    Application B
    • pH: 0 to 14
    Application H
    • pH: 0 to 12

  • Measuring principle

    Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP and rH value (in rH mode)

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B, Type N
    Metal lead: Ag/AgCl
    Open aperture: Ceramic junction,
    zirconium dioxide
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16,57 inch)

  • Process temperature

    Application B and H:
    0 to 140 ° C (32 to 284 ° F)
    Version TB:
    0 to 140 ° C (32 to 284 ° F)
    Version TU, TP (pressurized reference):
    0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
    maximum 100 ° C (212 ° F) in continuous operation due to increasing
    pressure drop at T> 100 ° C (212 ° F)

  • Process pressure

    Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
    Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Process technology and monitoring of processes with:
    – Rapidly changing pH values
    – High levels of electrode poisons, such as H2S

  • Characteristic

    Digital pH/ORP electrode for chemical process with an ion trap for poison-resistant reference

  • Measurement range

    ORP: –1 500 to 1 500 mV
    Application B
    • pH: 0 to 14
    Application H
    • pH: 0 to 12

  • Measuring principle

    Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP and rH value (in rH mode)

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B, Type N
    Metal lead: Ag/AgCl
    Open aperture: Ceramic junction,
    zirconium dioxide
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.68, 8.77, 14.04 and 16,57 inch)

  • Process temperature

    Application B and H:
    0 to 140 ° C (32 to 284 ° F)
    Version TB:
    0 to 140 ° C (32 to 284 ° F)
    Version TU, TP (pressurized reference):
    0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
    maximum 100 ° C (212 ° F) in continuous operation due to increasing
    pressure drop at T> 100 ° C (212 ° F)

  • Process pressure

    Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
    Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

Field of application
Memosens CPS76E is the heavy-duty specialist for simultaneous pH and ORP measurement. Its unique, contamination-resistant reference guarantees stable measurement in polluted, poisoning media and in media with low conductivity. Thanks to Memosens 2.0 digital technology, CPS76E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Processes in chemical industry and monitoring of processes with:Quickly changing pH or ORP valuesHigh proportion of electrode poisons such as H2S With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zone

Digital pH sensor Memosens CPS71E

Memosens 2.0 pH electrode for chemical processes and poisoning media

  • Measuring principle

    Potentiometric

  • Application

    Process technology and monitoring of processes with:
    • Rapidly changing pH values
    • High proportion of electrode poisons such as H2S

  • Characteristic

    Digital pH electrode for chemical process with an ion trap for poison-resistant reference

  • Measurement range

    Application B:
    • pH: 0 to 14
    Application H:
    • pH: 0 to 12

  • Measuring principle

    Gel compact electrode with ceramic junction and ion trap

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type B, Type N
    Metal lead: Ag/AgCl
    Open aperture: Ceramic junction, zirconium dioxide
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.47 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.72, 8.86, 14.2 and 16.7 inch)

  • Process temperature

    1 to 140 °C (32 to 284 °F)

  • Process pressure

    0,8 to 14 bar (11,6 to 203 psi) (absolute)

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2.

  • Connection

    Inductive, contactless connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Additional certifications

    Additional certifications

Field of application
Memosens CPS71E is specially designed for demanding processes. Its unique, contamination-resistant reference and its resistance to moisture ensure reliable measurement even in heavily polluted, aggressive media such as strong acids and bases. Thanks to Memosens 2.0 digital technology, CPS71E offers extended storage of calibration and process data providing the perfect basis for predictive maintenance. Pre-calibration in the lab and quick sensor exchange on site maximize process uptime.

Processes in chemical industry and monitoring of processes with:High proportion of electrode poisons such as H2SQuickly changing pH values With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
The electrode’s unique ion trap prevents poisoning of the junction and reference, making it resistant to strong acids and bases and ensuring a long sensor lifetime. The optional pressurized reference allows for reliable measurement in blocking media such as dispersions.Flexible installation thanks to optional upside-down mounting Inductive cable connection and non-contact signal transmission eliminate any problems due to moisture or corrosion and increase process integrity.Fast sensor exchange on site reduces process downtime and operating costs. Memosens 2.0 digital technology makes trend identification and predictive maintenance possible thanks to its extended storage of calibration and process data. The technology paves the way for advanced IIoT services.

Digital ORP sensor Memosens CPS62E

Memosens 2.0 ORP electrode for the chemical and life sciences industries

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Hygiene and sterile applications (sterilizable, autoclavable):
    • Fermenter
    • Biotechnology
    • Pharma

  • Characteristic

    Digital ORP electrode for hygienic production processes with ion trap
    for long-term stable reference

  • Measurement range

    –1 500 to 1 500 mV

  • Measuring principle

    Gel compact electrode with ceramic junction and ion trap
    Measuring element platinum cap

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    Metal lead: Ag/AgCl
    Open aperture: Ceramic junction,
    zirconium dioxide
    ORP measuring element: Platinum
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.46 inch)
    Shaft lengths: 120, 225 and 360 mm
    (4.68, 8.77 and 14.04 inch)

  • Process temperature

    0 to 100 °C (32 to 212 °F)
    0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only)

  • Process pressure

    0.8 to 7 bar (11.6 to 101.5 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2

  • Connection

    Inductive, digital connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

  • Additional certifications

    Additional certifications

Field of application
Memosens CPS62E is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media, in low conductivities and at high temperatures. Thanks to Memosens 2.0 digital technology, CPS62E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Process technology and monitoring of processes with:- Quickly changing ORP values- High proportion of electrode poisons such as H2SChemical processesHygienic and sterile applications:- Fermenters- Biotechnology- Life sciencesWith ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Sensor resists strong acids and bases and high organic loads. Maintains high accuracy even after CIP/SIP or autoclaving. Free from animal-based materials and from acrylamide. Upside-down mounting option allows for flexible installation. Maximum process safety is ensured by non-contact, inductive signal transmission. Minimized process downtime and extended sensor lifetime result in reduced operating costs.

Digital pH sensor Memosens CPS61E

Memosens 2.0 glass sensor for the food & beverage industry and for bioreactors in biotech industry

  • Measuring principle

    Potentiometric

  • Application

    Hygienic and sterile applications (sterilizable, autoclavable):
    • Bioreactor/fermenter
    • Biotechnology
    • Pharmaceutical industry
    • Foods

  • Characteristic

    Digital pH electrodes for hygienic production processes with ion trap for
    long-term stable reference

  • Measurement range

    pH: 0 to 14

  • Measuring principle

    Gel compact electrode with ceramic junction and ion trap

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Material

    Sensor shaft: Glass to suit process
    pH membrane glass: Type N
    Metal lead: Ag/AgCl
    Open aperture: Ceramic junction, zirconium dioxide
    O-ring: FKM
    Process coupling: PPS fiber-glass reinforced
    Nameplate: Ceramic metal oxide

  • Dimension

    Diameter: 12 mm (0.47 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.72, 8.86, 14.2 and 16.7 inch)

  • Process temperature

    Application N:
    0 to 100 °C (32 to 212 °F)
    Up to 140 °C (284 °F) for sterilization

  • Process pressure

    0.8 to 7 bar (11.6 to 101.5 psi) absolute

  • Temperature sensor

    NTC 30k

  • Ex certification

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2.

  • Connection

    Inductive, contactless connection head with Memosens 2.0 technology

  • Ingress protection

    IP68

Field of application
Keep the pH value in the optimum range and maximize your product yield with Memosens CPS61E. Its rugged design and long-term stability ensure extremely accurate and reproducible measured values even after CIP/SIP or autoclaving. CPS61E features Memosens 2.0 digital technology, offering extended storage of calibration and process data for predictive maintenance. The sensor resists moisture and enables lab calibration, enhancing process integrity and increasing process uptime.

Memosens CPS61E measures pH in:
Biotech and pharma industries – Bioreactors/fermenters: process control in enzyme production- Bioreactors/fermenters: control of culture growth
Food & Beverage- CIP/SIP applications
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
A pharma certificate of compliance with sensor serial number specified is available.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. The sensor’s exceptional accuracy and reproducibility help you to keep the pH value in the optimum range for a maximized product yield. A special glass membrane and reference system makes the sensor CIP/SIP and autoclaving resistant (up to 140°C/284°F) offering maximum long-term stability.The sensor protects your product quality with its certified biocompatibility according to USP class VI, FDA compliance of wetted parts, VO 1935/2004 compliance, no cytotoxicity, bioreactivity or animal-based materials. Streamline maintenance of CPS61E with the Memobase Plus software that automatically stores and documents all relevant sensor and process data. Maximum process safety through non-contact, inductive signal transmission Reduced operating costs thanks to minimized process downtime and extended sensor lifetime.

Digital pH sensor Memosens CPS171D

Memosens glass electrode for bioreactors in the biotech industry and for the food industry

  • Measuring principle

    Potentiometric

  • Application

    Hygienic and sterile applications, bioreactor, fermenter, biotechnology, pharmaceutical industry, foods

  • Characteristic

    Digital pH electrodes for bioreactors and biotechnology production processes with ion
    trap for long-term stable reference

  • Measurement range

    pH 0 to 14

  • Measuring principle

    Ceramic diaphragm, ion-trap

  • Design

    All shaft lengths with temperature sensor
    Advanced gel technology
    Digital electrode with Memosens technology

  • Material

    Glass and ceramic

  • Dimension

    Diameter: 12 mm (0.47 inch)
    Shaft lengths: 120, 225, 360 and 425 mm
    (4.72, 8.86, 14.2 and 16.7 inch)

  • Process temperature

    0 to 135 °C (32 to 275 °F)

  • Process pressure

    1 to 7 bar abs (14.5 to 101.5 psi)

  • Temperature sensor

    NTC 30k

  • Ex certification

    IECEx, ATEX, NEPSI, FM, CSA

  • Connection

    Inductive, digital connection head with Memosens technology

Field of application
Keep the pH value of your batch in the optimum range and maximize your product yield with Memosens CPS171D. Thanks to its rugged design and long-term stability, it provides extremely accurate, reproducible and reliable measuring values even after CIP/SIP and autoclaving. Memosens CPS171D is not the latest Memosens generation. To get information on the new Memosens CPS61E sensor with extended functionality, click here.

Digital ORP sensor Memosens CPF82E

Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Flotation, leaching, neutralization, outlet monitoring

  • Characteristic

    Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4″

  • Measurement range

    -1500mV to +1500mV

  • Measuring principle

    Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum ring

  • Design

    Compact electrode in PPS housing with NPT3/4″ process connection

  • Material

    Housing: PPS
    ORP electrode: platinum ring
    Double chamber reference system: KNO3 and KCl/AgCl

  • Dimension

    Diameter: 22 mm (0.87 inch)
    Length: 150 mm (5.91 inch)

  • Process temperature

    0 to 80 °C (32 to 170 °F)

  • Process pressure

    1 to 10 bar abs at 80 °C
    (15 to 145 psi abs at 176 °F)

  • Temperature sensor

    NTC

  • Ex certification

    (optional) FM IS NI Cl. I Div.1&2, Groups A-D

  • Connection

    Process connection: NPT 3/4″
    Memosens plug

  • Ingress protection

    IP 68

Field of application
Memosens CPF82E is the digital, robust solution for ORP measurement in harsh environments. Its large, dirt-repellent PTFE junction guarantees low maintenance while its integrated assembly offers easy and compact installation. Thanks to Memosens 2.0 digital technology, CPF82E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Memosens CPF82E is the robust ORP sensor for treatment of industrial water and wastewater and for processes in mining industries. It monitors:Inlet and outletNeutralizationFlotationLeachingWith CSA C/US approval for use in hazardous areas, zones 0, 1 and 2.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Long time stable: Double junction provides better protection against electrode poisoning ions such as S2- or CN-. Robust polymer housing protects against mechanical damage. The sensor is suitable for flow and immersion installation Non-contact, inductive signal transmission maximizes process safety.Minimum process downtime and extended sensor lifetime reduce operating costs.

Digital pH sensor Memosens CPF81E

Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries

  • Measuring principle

    Potentiometric

  • Application

    Flotation, leaching, neutralization, outlet monitoring

  • Characteristic

    Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4″

  • Measurement range

    pH 0 to 14

  • Measuring principle

    Gel-compact electrode with double chamber reference system, kalium nitrate bridge electrolyte and PTFE-diaphragm

  • Design

    Compact electrode in PPS housing with NPT 3/4″ process connection

  • Material

    Housing: PPS
    pH electrode: lead-free membrane glass
    Double chamber reference system: KNO3 and KCl/AgCl

  • Dimension

    Diameter: 22 mm (0.87 inch)
    Length (protcetion guard, long shaft): 150 mm (5.91 inch)
    Length (flat membrane): 140 mm (5.51 inch)

  • Process temperature

    Version LH: 0 to 110 °C (32 to 230 °F)
    Version NN: 0 to 80 °C (32 to 170 °F)

  • Process pressure

    1 to 10 bar abs at 80 °C
    (15 to 145 psi at 176 °F)

  • Temperature sensor

    NTC 30K

  • Ex certification

    (optional) FM IS NI Cl. I Div.1&2, Groups A-D

  • Connection

    Memosens plug

  • Ingress protection

    IP68

Field of application
Memosens CPF81E is the digital, robust solution for harsh environments. It measures reliably and accurately even in abrasive media and at high flow rates. With its integrated assembly, the electrode saves installation space. Thanks to Memosens 2.0 digital technology, CPF81E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

Memosens CPF81E is the robust pH sensor for processes in mining industries and treatment of industrial water and wastewater. It monitors:FlotationLeachingNeutralizationInlet and outlet With CSA C/US approval for use in hazardous areas, zones 0, 1 and 2.

Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Long time stable: Double junction provides better protection against electrode poisoning ions such as S2- or CN-. Robust polymer housing protects against mechanical damage. Optional flat membrane makes the sensor suitable for high flow rates and abrasive media. Non-contact, inductive signal transmission ensures maximum process safety. Maximum process uptime and extended sensor lifetime reduce operating costs.

Process spectrometer Memosens Wave CKI50

Memosens Wave spectrometer for color measurement in the Food & Beverage, Chemical and Life Sciences industries

  • Measuring principle

    Absorption

  • Application

    Color measurement CIE Lab

  • Measurement range

    L: 0 to 100
    a: -150 to 100
    b: -100 to 150

  • Material

    Measuring head: 1.4404/AISI316L
    Window: Sapphire
    O-rings: FFKM
    Gasket seal: PEEK

  • Process temperature

    -20 to 60 °C (-4 to 140 °F)
    60 to 140 °C (140 to 284 °F) with water cooling

  • Process pressure

    0.5 to 10 bar (7.3 to 145 psi) (absolute)

  • Ex certification

    ATEX/IECEx II 1/2G Ex ia op is/db [ia Ga] IIC T6…T3 Ga/Gb

  • Ingress protection

    IP 69 (NEMA 6P)

Field of application
Memosens Wave CKI50 impresses with its compact design, which allows the spectrometer to provide reliable and fast color control directly in the process. At the same time, the process spectrometer ensures hygiene and material standards in accordance with the specifications of the food industry. Thanks to a preset color model and the connection to a Liquiline transmitter, commissioning is very easy and you benefit from stable measurements.

Quality control: Color deviations in end products are caused by color variations in the raw materials. Therefore, recognizing them and initiating appropriate adjustments is crucial Filling control: Increasing product diversity and rising production speed pose a risk of incorrect bottling. Reliable and fast color detection is crucial.Phase control: With color detection, phases in pipes can be recognized quickly and product losses can be minimized, e.g. when changing products or during cleaning.

Benefits
Compact design: Determination of color across the entire color spectrum with just a single device.Easy commissioning: Thanks to Memosens technology and the Liquiline transmitter, installation is quick and easy. No calibration required, only a reference spectrum of the zero point has to be recorded.Robust color measurement: Highly repeatable and long-term reliable color measurements even in demanding process environments, thanks to a high resistance to water ingress and vibration as well as higher temperatures.Safe and efficient process control: The hygienic design ensures products are made safely. By checking the color directly in the process, product loss and potential health risks to consumers can be prevented

PAH sensor Memosens CFS51

Memosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)

  • Measuring principle

    Fluorescence measurement

  • Application

    PAH measurement in marine exhaust gas cleaning systems

  • Measurement range

    0.000 to 5000 PAHphe

  • Design

    40 mm sensor

  • Material

    Titanium grade 3.7035
    Optical windows: sapphire
    O-rings: FKM

  • Process temperature

    -5 to 55 °C (20 to 130 °F)

  • Process pressure

    10 bar abs. (just the sensor)
    6 bar abs. (combination sensor and assembly)

  • Ingress protection

    IP68
    NEMA 6P

  • Additional certifications

    Marine type approvals by DNV, LR, BV, ABS
    Statement of compliance according to MEPC.259(68) and MEPC.340(77) by DNV

Field of application
The rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel – supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.

Memosens CFS51 measures PAHs with high accuracy in both the inlet and outlet of marine exhaust gas cleaning systems (scrubbers) and is suitable for all discharge water flow rates.The sensor is certified by the following approval bodies: DNV (Det Norske Veritas)LR (Lloyd’s Register)BV (Bureau Veritas)ABS (American Bureau of Shipping) For washwater monitoring in EGCS, the PAH sensor is also available as an approved all-in-one solution including pH and turbidity measurement.

Benefits
The uniquely long factory maintenance interval saves you a lot of costs and organizational effortThe optionally available flow assembly holds the sensor at the ideal installation angle to minimize disturbing influences caused by air bubbles. In addition, it can be tilted for quick mounting and dismounting of the sensor.DNV approved integrated turbidity correction in the range of 0-50 FNUHigh material compliance of sensor and flow assembly according to IACS E10 (flame retardancy)The solid-state reference makes calibration very easy for the end user – and you can completely eliminate the need for toxic phenantrene, which increases safety for your employees and the environmentThe suitability of the solid-state reference for calibration and readjustment of the PAH sensor on board was confirmed by DNV

Cleaning and calibration system Liquiline Control CDC90

Fully automatic system for pH and ORP measuring points in all industries

  • Measuring principle

    Potentiometric

  • Application

    Automates Memosens pH and ORP measuring points in all industries

  • Installation

    Complete automated cleaning and validation system including a selectable retractable holder

  • Characteristic

    Full automatic cleaning, monitoring and validation system for Memosens sensor

  • Design

    Compact cleaning system to connect on a retractable holder including transmitter

  • Dimension

    237 x 194 x 162 mm (l x h x w)
    9.33 x 7.64 x 6.38 inch (l x h x w)

  • Connection

    DCS/PLS connection on Modbus TCP, Ethernet IP, Profinet, ProfibusDP and current in/ output

  • Additional certifications

    CE, CSA general purpose

Field of application
The Liquiline Control CDC90 plug & play system automates Memosens pH and ORP measuring points in all industries. It cleans, validates, calibrates and adjusts up to two sensors automatically, reducing maintenance effort, improving working safety in harmful areas and helping to ensure the yield and quality of your product. It can easily be integrated into existing plant infrastructures and allows convenient remote control of your measuring points via any process control system or mobile device.

Liquiline Control CDC90 automates pH and ORP measuring points in all industries. It is suitable for each application where:
The sensors must be cleaned and/or calibrated frequently.
The measuring point is difficult to access.
The measuring point is in a harmful environment.
The process requires reproducible precise pH measurement.
The process requires measurement at frequent intervals.
The performance of the measuring point must be controlled and documented frequently.

Benefits
Optimized cleaning and calibration cycles ensure reliable and reproducible measured values that help you to improve product yield, product quality and raw material consumption. Pro-active cleaning and calibration in case of sensor blocking and fouling ensures reliable values to keep your product safe. Increased safety for your service personnel as it minimizes maintenance actions in difficult-to-access areas and harsh or harmful environments. Seamless system integration into your process control system thanks to certified communication standards such as 0/4…20mA, PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET and web server technology.Pre-defined cleaning and calibration programs allow a quick start and commissioning of Liquiline Control CDC90 and keep your investment effort low.

Digital free chlorine sensor Memosens CCS51D

Memosens sensor for drinking water, pool and process water as well as utilities in all industries

  • Measuring principle

    Free chlorine

  • Application

    Ensuring reliable disinfection in drinking water
    Process water
    Dosing disinfectant efficiently in pool water
    Detect the absence or presence of free chlorine in Utilities
    Guarantee food safety and provide hygienic packaging and bottling

  • Characteristic

    Amperometric measurement of dissolved free chlorine

  • Measurement range

    Trace: 0 to 5 mg/l HOCl
    Standard: 0 to 20 mg/l HOCl
    High: 0 to 200 mg/l HOCl

  • Measuring method

    Closed, membrane covered measuring cell
    Reduction of free chlorine at the cathode

  • Design

    Closed amperometric 2-electrode measuring cell with PVDF membrane

  • Material

    Sensor shaft: POM
    Membrane: PVDF
    Membrane cap: PVDF
    Sealing ring: FKM

  • Dimension

    Diameter: 25 mm (0.98 inch)
    Length: 161 mm (6.34 inch)

  • Process temperature

    0 to 55 °C (32 to 130 °F), non-freezing

  • Process pressure

    Max. 1 bar (max. 14.5 psi)

  • Temperature sensor

    10k NTC integrated (Memosens)

  • Connection

    Inductive, digital connection head with Memosens

Field of application
Memosens CCS51D is a robust, low-maintenance sensor for free chlorine. It provides high-precision measurement with long-term stability in drinking water, pool and process water and ensures consistent disinfection monitoring even at low water volumes. The free chlorine sensor features extremely fast response times guaranteeing efficient process control. Memosens CCS51D is not the latest Memosens generation. More information on the new Memosens CCS51E sensor with extended functionality here.

Memosens CCS51D is a free chlorine sensor for skid builders and end customers. It measures reliably in:Drinking water – to ensure reliable disinfectionProcess water – for hygienic and safe packaging and bottling of productsUtilities – to detect the absence or presence of free chlorinePool water – to dose disinfectant efficiently

Benefits
The right sensor version for every application: From trace measurement up to free chlorine concentrations of 200 mg/l. Fast response time (t90 < 25 s) provides an accurate process view and enables prompt reaction to process changes as well as efficient process control.Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for individually adapted disinfectant dosing. The low-maintenance, amperometric sensor reduces the cost of ownership of the measuring point, particularly compared to colorimetric measuring systems. More process up-time thanks to fast sensor exchange: pre-calibrate the sensor in your lab and then swap it into your process with plug & play.Connection to the Liquiline multiparameter transmitter allows for easy combination with other relevant parameters of liquid analysis such as pH and ORP.

Digital chlorine dioxide sensor Memosens CCS50D

Memosens sensor for water, process water and utilities in all industries

  • Measuring principle

    Chlorine dioxide

  • Application

    Adequate disinfection in drinking water, preventing of pathogen formation in cooling water systems, water used to wash pre-packaged vegetables, ensures the absence of chlorine dioxide in beverage systems

  • Characteristic

    Amperometric measurement of dissolved chlorine dioxide

  • Measurement range

    Trace: 0 to 5 mg/l ClO2
    Standard: 0 to 20 mg/l ClO2
    High: 0 to 200 mg/l ClO2

  • Measuring principle

    Closed, membrane covered measuring cell
    Reduction of chlordioxide (ClO2) to chloride at the cathode with appr. 120mV

  • Design

    Closed amperometric 2-electrode measuring cell with PVDF membrane

  • Material

    Sensor shaft: POM
    Membrane: PVDF
    Membrane cap: PVDF

  • Dimension

    Diameter: 25 mm (0.98 inch)
    Length: 161 mm (6.34 inch)

  • Process temperature

    0 to 55 °C , non-freezing
    (32 to 130 °F)

  • Process pressure

    Max. 2 bar abs
    (Max. 29 psi abs)

  • Temperature sensor

    10k NTC integrated (Memosens)

  • Connection

    Inductive, digital connection head with Memosens

Field of application
Memosens CCS50D is a robust, low maintenance sensor for chlorine dioxide measurement. It provides stable and fast measured values in drinking water, process water and utilities. The sensor can be used to ensure efficient disinfection for highest water quality and safety, to avoid overdosing of chlorine dioxide or to ensure the absence of ClO2 in beverage plants and reverse osmosis. Memosens CCS50D is not the latest Memosens generation. More information on the new Memosens CCS50E sensor here.

Memosens CCS50D is a chlorine dioxide sensor for skid builders and end customers. It measures reliably in:Drinking water to ensure sufficient disinfectionCooling systems or towers to avoid pathogen growthProcess water – for hygienic and safe packaging and bottling of productsBeverage plants to secure the absence of chlorine dioxide

Benefits
The right sensor version for every application: From trace measurement up to chlorine dioxide concentrations of 200 mg/l.Fast response time provides accurate process view and enables prompt reaction to process changes as well as efficient process control. Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for lowest disinfectant concentration. Flexible installation: sensor can be installed in the CCA151 and CCA250 flow assemblies or in immersion assemblies. Measurement virtually flow independent at flow velocities above 5 l/h (CCA151), 30 l/h (CCA250) or above 15 cm/s (immersion).More process up-time thanks to fast sensor exchange: precalibrate the sensor in your lab and then swap it into your process with plug & play. Connection to the Liquiline multiparameter transmitter allows easy combination with other relevant parameters of liquid analysis.

Orthophosphate analyzer Liquiline System CA80PH

Colorimetric system for wastewater monitoring and optimization of process control

  • Measuring principle

    Colorimetric

  • Characteristic

    Process analyzer for orthophosphate in aqueous solutions
    Comply with standard colorimetric measuring principle, molybdenum blue method, following DIN EN 1189 or molybdate vanadate method

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39.2 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    At atmospheric pressure, < 0.2 bar

  • Sample flow rate

    Min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Suspended solids content
    Turbitity < 50 NTU, aqueous, homogenized

  • Application

    Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    24 VDC ± 10%
    50 ± 1 or 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP

  • Input

    1 or 2 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0 to 2.5 mg/l PO4-P (blue method)
    0.05 to 10 mg/l PO4-P (blue method)
    0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
    0.5 to 20 mg/l PO4-P (yellow method)
    0.5 to 50 mg/l PO4-P (yellow method)
    0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method)

  • Consumables

    Reagents and standard solutions CY80H as well as cleaner CY800 (blue method) are necessary for the operation
    Regular maintenance is done with the parts of the maintenance kit CAV800

Field of application
Liquiline System CA80PH offers online orthophosphate measurement for precise dosing of precipitants in wastewater treatment. As all Liquiline System analyzers, it enables plug & play of up to 4 Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low consumption of reagents save you operating costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.

Liquiline System CA80PH supports you in optimizing the cleaning capacity of wastewater treatment plants. It monitors and controls:
Precipitant dosing in aeration basins
Wastewater treatment plant outlets
In industrial applications, Liquiline System CA80PH is used for the monitoring of cooling water cycles.

Benefits
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation
Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors Advanced diagnostics with remote access for increased process safety Reduced operating costs through automatic calibration and cleaning and long reagent shelf life with cooling moduleAvailable with both standardized measuring methods covering all applications: Molybdenum blue method and Molybdate Vanadate yellow method

COD analyzer Liquiline System CA80COD

Analyzer for chemical oxygen demand in environmental monitoring, industrial and municipal wastewater

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for chemical oxygen demand (COD)

  • Size

    Housing (open version):
    793 x 530 x 417 mm
    31.22 x 20.87 x 16.42 in
    Housing (closed version):
    793 x 530 x 463 mm
    31.22 x 20.87 x 18.23 in
    Housing with base:
    1723 x 530 x 463 mm
    67.83 x 20.87 x 18.23 in

  • Design

    Open design, cabinet and stand housing
    High-Performance plastic ASA-PC, additional stand coated steel

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)
    Outdoor version: – 20 to 40 °C (-4 to 104 °F)

  • Process pressure

    Atmospheric

  • Sample flow rate

    min. 30 ml/min

  • Consistency of the sample

    Aqueous homogeneous sample

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors
    Automatic calibration and cleaning
    User-configurable measuring, cleaning and calibration intervals
    Self-priming analyzer with optical dosing unit l
    Dilution module (optional)
    Digital communication for remote access

  • Application

    Environmental monitoring, limit value monitoring of industrial and municipal waste water

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%
    50 ± 1 oder 60 ± 1,2 Hz

  • Output / communication

    2x 0/4 to 20 mA
    Modbus RS485/TCP (optional)
    Webserver (optional)
    EtherNet/IP
    PROFIBUS DP
    Alarmrelay

  • Input

    1 measuring channel
    1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)

  • Measurement range

    0 to 500 mg/l O2 COD chromate method
    0 to 5000 mg/l O2 COD chromate method
    0 to 5000 mg/l O2 COD chromate method + dilution module (1:4)

  • Consumables

    Reagents and standard solutions CY80COD are necessary for the operation

Field of application
Liquiline System CA80COD offers constant online measurement of the chemical oxygen demand (COD). It supports you in monitoring the cleaning capacity of wastewater treatment plants and enables load-based billing for industrial dischargers. Automatic calibration and cleaning save operating costs while advanced diagnostics with remote access help to provide process documentation to authorities. The COD analyzer’s software-controlled safety functions ensure the highest level of occupational safety.

The Liquiline System COD analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water

Benefits
Established COD dichromate method directly comparable to laboratory results. Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater. Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications.Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing.Easy upgrade of functionality to a complete measuring station – simply by adding modules and connecting Memosens sensors.

Translate »