Guided radar measurement Time-of-Flight Levelflex FMP57
The standard sensor for highest demands for level measurement in bulk solids
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device for pulling forces up to 30kN
Rod probe, Rope probe
Integrated data memory. Factory precalibrated, Reliable measuring: in dusty atmosphere, in high + narrow silos, in vessels + obstacles. -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus),
4-wire (HART),
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in) -
Ambient temperature
-40…+80 °C
(-40…+176 °F) -
Process temperature
-40…+150 °C
(-40…+302 °F) -
Process pressure / max. overpressure limit
Vacuum…16 bar
(Vacuum…232 psi) -
Main wetted parts
Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA -
Process connection
Thread:
G1 1/2, MNPT1 1/2
Flange:
ASME 1 1/2″…8″,
DN50…DN200,
JIS 10K -
Sensor length
Rod probe: 4 m (13 ft)
Rope probe: 45 m (148 ft) -
Max. measurement distance
Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m…25 m (66 ft…82 ft) Min DK >1.4;
25 m…30 m (82ft…98 ft) Min DK >1.6;
30 m…45 m (98ft…148 ft) Min DK>1,9 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
-
Marine approval
GL/ ABS/ LR/ BV/ DNV/ KR
-
Options
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth®
Field of application
Levelflex FMP57 is the sensor for the highest demands in bulk solids and best suited for measurements in high silos, bunkers or stockpiles. Providing rope probes up to a length of 45m the FMP57 is also suited to measurements in high silos. Levelflex FMP57 guided radar is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.
Version with rod or rope probe.
Process connections: Thread or flange
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, SIL, marine approval, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP56
Economically efficient basis model for all level applications in bulk solids
-
Measuring principle
Guided radar
-
Characteristic / Application
Basic device for pulling forces up to 12 kN
Rope probe
Integrated data memory, Factory precalibrated, Reliable measuring: in dusty atmosphere, in high + narrow silos, in vessels + obstacles. -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus),
4-wire (HART),
Bluetooth® wireless technology and App (optional) -
Accuracy
Rope probe: +/- 2 mm (0.08 in)
-
Ambient temperature
-40…+80 °C
(-40…+176 °F) -
Process temperature
–40…+120 °C
(–40…+248 °F) -
Process pressure / max. overpressure limit
Vacuum…16 bar
(Vacuum…232 psi) -
Main wetted parts
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA -
Process connection
Thread:
G 3/4, MNPT 3/4 -
Sensor length
Rope probe: 12 m (40 ft)
-
Max. measurement distance
Rope: 12 m (40 ft)
Min DK >1.4 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
-
Safety approvals
SIL
-
Options
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth®
Field of application
Levelflex FMP56 is particularly designed for light-duty process conditions as they occur in silos and storage tanks for solids. FMP56 guided radar offers maximum reliability even in case of dusty atmosphere in narrow silos or in vessels with obstacles. Levelflex FMP56 is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement. Remote access with SmartBlue app via Bluetooth module is available.
Version with rope probe.
Process connections: Thread or adapter flange
Temperature: -40 to +120°C (-40 to +248°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: 12m (39ft)
Accuracy: ± 2mm (0.08″)
International explosion protection certificates, SIL, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP55
The Multiparameter device is the innovation in interface measurement
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device Multiparameter (capacitance and guided radar)
Rod probe, Rope probe, Coaxial probe
Integrated data memory, Factory precalibrated, Reliable measuring: for interface with emulsion, in case of moved surface + foam, for changing medias. -
Interface measurement
Interfaces liquid / liquid also with emulsion layers;
Simultaneous measurement of interface and overall level -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in) -
Ambient temperature
-40…+80 °C
(-40…+176 °F) -
Process temperature
-40…+200 °C
(-40…+392 °F) -
Process pressure / max. overpressure limit
Vacuum…40 bar
(Vacuum…580 psi) -
Main wetted parts
Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA -
Process connection
Flange:
ASME 1 1/2″…6″,
DN50…DN150,
JIS 10K -
Sensor length
Rod probe: 4 m (13 ft)
Rope probe: 10 m (33 ft)
Coaxial probe: 6 m (20 ft) -
Max. measurement distance
Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.1, B31.3
AD2000 -
Marine approval
GL/ ABS/ LR/ BV/ DNV/ KR
-
Options
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth®
Field of application
Levelflex FMP55 guided radar with SensorFusion offers the worldwide first combination of the capacitance and guided radar measuring principle in one device. The instrument guarantees safe measured value acquisition even in emulsion layers and issues level and interface layer signals simultaneously. This makes the FMP55 Multiparameter the new standard in interface measurement especially in the oil & gas, chemical and petrochemical industry.
Version with rod, rope or coax probe.
Process connections: Thread or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13t), rope 10m (33ft), coax 6m (20ft)
Accuracy: Rod ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)Worlds easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP54
For high temperature and high pressure applications in the oil & gas, chemical and power industry
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device high pressure/ high temperature
Rod probe, Rope probe, Coaxial Probe
Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias -
Interface measurement
Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in) -
Ambient temperature
-50…+80 °C
(-58…+176 °F) -
Process temperature
XT: -196…+280 °C
(-321…+536 °F)
HT: -196…+450 °C
(-321…+842 °F) -
Process pressure / max. overpressure limit
Vacuum…400 bar
(Vacuum…5800 psi) -
Main wetted parts
Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic -
Process connection
Thread:
G 1 1/2, MNPT 1 1/2
Flange:
ASME 2″…4″,
DN50…DN100,
JIS 10K, 63K,
Fisher
Masoneilan -
Sensor length
Rod probe: 10 m (33 ft)
Rope probe: 45 m (148 ft)
Coaxial probe: 6 m (20 ft) -
Max. measurement distance
Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m…30 m (82 ft…98 ft) Min DK>1.6;
30 m…45 m (98 ft…148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.1, B31.3
AD2000
Steam boiler approval -
Marine approval
GL/ DNV/ ABS/ LR/ BV
-
Options
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth® -
Application limits
Application limits
Field of application
Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.
Version with rod, rope or coax probe.
Process connections: Thread or flange
Temperature: -196 to +450°C (-320 to +842°F)
Pressure: -1 to +400bar (-14.5 to +5,800psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: rod ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, steam boiler approval, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP53
For the highest hygiene requirements in the food and life sciences industry
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device. Hygiene
Rod probe,
ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head. -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe:+/- 2 mm (0.08 in)
-
Ambient temperature
-20…+80 °C
(-4…+176 °F) -
Process temperature
-20…+150 °C
(-4…+302 °F) -
Process pressure / max. overpressure limit
Vacuum…16 bar
(Vacuum…232 psi) -
Main wetted parts
Rod probe:
304, 304L, 316L, PEEK -
Process connection
Thread:
M24 -
Process connection hygienic
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS -
Sensor length
Rod probe: 6 m (20 ft)
-
Max. measurement distance
Rod: 6 m (20 ft)
Min DK>1.6 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
-
Hygienic approvals
3A, EHEDG
CoC ASME-BPE -
Options
Sensor remote with 3 m/9 ft or 6 m/18 ft cable,
Weld-in adpater,
Remote operation via SmartBlue App using Bluetooth® -
Application limits
Application limits
Field of application
Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.
Version with rod probe.
Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO, Varivent N, SMS)
Temperature: -20 to +150°C (-4 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 6m (20ft)
Accuracy: ±2mm (0.12″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP52
Coated probe for use in aggressive liquids
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device coated for corrosive media
Rod probe, Rope probe
Wetted parts FDA listed materials, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias. -
Interface measurement
Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in) -
Ambient temperature
-40…+80 °C
(-40…+176 °F) -
Process temperature
-50…+200 °C
(-58…+392 °F) -
Process pressure / max. overpressure limit
Vacuum…40 bar
(Vacuum…580 psi) -
Main wetted parts
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA -
Process connection
Flange:
ASME 1 1/2″…6″,
DN50…DN100,
JIS 10K -
Process connection hygienic
Tri-Clamp
DIN11851 -
Sensor length
Rod probe: 4 m (13 ft)
Rope probe: 45 m (148 ft) -
Max. measurement distance
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m…30 m (82 ft…98 ft) Min DK>1.6;
30 m…45 m (98 ft…148 ft) Min DK>1,9 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
ASME B31.1, B31.3
AD2000 -
Hygienic approvals
3A, EHEDG
-
Marine approval
GL/ ABS/ LR/ BV/ DNV
-
Options
Sensor remote with 3 m/ 9 ft cable,
Gas-tight feed through,
Remote operation via SmartBlue App using Bluetooth® -
Application limits
Application limits
Field of application
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP51
The standard sensor for highest demands in liquid level measurement
-
Measuring principle
Guided radar
-
Characteristic / Application
Premium device
Rod probe, Rope probe, Coaxial probe
Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias. -
Interface measurement
Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in) -
Ambient temperature
-50…+80 °C
(-58…+176 °F) -
Process temperature
-50…+200 °C
(-58…+392 °F) -
Process pressure / max. overpressure limit
Vacuum…40 bar
(Vacuum…580 psi) -
Main wetted parts
Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA -
Process connection
Thread:
G3/4…G1 1/2;
MNPT 3/4…MNPT1 1/2
Flange:
ASME 1 1/2″…8″,
DN50…DN 200,
JIS 10K -
Sensor length
Rod probe: 10 m (33 ft)
Rope probe: 45 m (148 ft)
Coaxial probe: 6 m (20 ft) -
Max. measurement distance
Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m…30 m (82ft…98 ft) Min DK>1.6;
30m…45 m (98ft…148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
ASME B31.1, B31.3
AD2000 -
Marine approval
GL/ ABS/ LR/ BV/ DNV
-
Options
Sensor remote with 3 m/ 9 ft cable,
Gas-tight feed through,
Remote operation via SmartBlue App using Bluetooth® -
Application limits
Application limits
Field of application
Levelflex FMP51 for level measurement even under extreme process conditions like high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod, rope or coax probe.
Process connections: Threads or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditions HistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP50
For all basic level applications in liquids
-
Measuring principle
Guided radar
-
Characteristic / Application
Basic device
Rod probe, Rope probe
Integrated data memory, Factory precalibrated, Reliable measuring for changing medias. -
Specialities
Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification -
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional) -
Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in) -
Ambient temperature
-20…+80 °C
(-4…+176 °F) -
Process temperature
-20…+80 °C
(-4…+176 °F) -
Process pressure / max. overpressure limit
Vacuum…6 bar,
(Vacuum…87 psi) -
Main wetted parts
Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton -
Process connection
Thread:
G 3/4, MNPT 3/4
Flange:
UNI Flange -
Sensor length
Rod probe: 4 m (13 ft)
Rope probe: 12 m (40 ft) -
Max. measurement distance
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6 -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
-
Options
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth® -
Application limits
Application limits
Field of application
Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
Process connections: Thread or adapter flange
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +87psi)
Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)
Accuracy: ±2mm (0.08″)
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditionsHistoROM data management concept for fast and easy commissioning, maintenance and diagnosticsHighest reliability due to new Multi-Echo Tracking evaluationHardware and software developed according to IEC 61508 up to SIL3Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycleSeamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)World’s easiest proof test for SIL and WHG saves time and costs
Radiometric level and density measurement Gammapilot FMG50
Compact transmitter for point level detection, continuous level, interface and density measurement
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Interface measurement
Interfaces liquid / liquid also with emulsion layers
Interfaces liquid / solid -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Accuracy
+/-1%
-
Ambient temperature
-40 °C…+80 °C,
(-40 °F…+176 °F) -
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Sensor length
PVT scintillator
400 mm…3000 mm,
>3000 mm cascade mode -
Max. measurement distance
Unlimited measuring range,
Cascade -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Safety approvals
Overfill protection WHG
SIL 2/3 -
Design approvals
EN 10204-3.1
-
Options
Display
-
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Accuracy
+/-1%
-
Ambient temperature
-40 °C…+80 °C,
(-40 °F…+176 °F) -
P
Electronic differential pressure Deltabar FMD72
Electronic differential pressure system utilizing two metal sensor modules and one transmitter
-
Measuring principle
Differential pressure
-
Characteristic
Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
-
Supply voltage
4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC -
Reference Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–40…+125°C
(–40…+257°F) -
Ambient temperature
–40…+80°C
(–40…+176°F) -
Measuring cell
400 mbar…10 bar
(6 psi…150psi) -
Vacuum resistance
10 mbar (0.15 psi)
-
Max. overpressure limit
160 bar (2400 psi)
-
Process connection
Threads
Flange (DIN, ASME,JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
316L, AlloyC,
-
Fill fluid
Silicone oil
Synthetic oil -
Material housing
Die-cast aluminum
Stainless steel -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG
3A
-
Measuring principle
Differential pressure
-
Characteristic / Application
Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
-
Supply / Communication
4…20 mA HART
-
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Ambient temperature
–40…+80°C
(–40… +176°F) -
Process temperature
–40…+125°C
(–40 … +257°F) -
Process pressure / max. overpressure limit
160 bar (2400 psi)
-
Pressure measuring range
400 mbar…10 bar
(6 psi…150 psi) -
Main wetted parts
Electronic differential pressure Deltabar FMD71
Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter
-
Measuring principle
Differential pressure
-
Characteristic
Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
-
Supply voltage
4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC -
Reference Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–25…+150°C
(–13…+302°F) -
Ambient temperature
–40…+80°C
(–40…+176°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi) -
Vacuum resistance
0 mbar
-
Max. Turn down
100 : 1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Threads
Flansch (DIN, ASME, JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
Ceramic
316L, AlloyC -
Material gasket
Viton, Kalrez, EPDM, NBR, Silicone
-
Fill fluid
Silicone Oil
-
Material housing
Die-cast aluminum
Stainless steel -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG,
3A
-
Measuring principle
Differential pressure
-
Characteristic / Application
Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
-
Supply / Communication
4…20 mA HART:
12…45V DC
Exia: 12…30V DC -
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Ambient temperature
–40…+80°C
(–40…+176°F) -
Process temperature
–25…+150°C
(–13…+302°F) -
Process pressure / max. overpressure limit
Ultrasonic measurement Time-of-Flight Prosonic FDU95
Ultrasonic sensor for level measurement for connection to FMU9x (measuring range up to 45m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2 mm + 0.17% of measured distance
-
Ambient temperature
-40 °C…80 °C
or 150 °C,
(-40 °F…176 °F
or 302 °F) -
Process temperature
-40 °C…80 °C
or 150 °C,
(-40 °F…176 °F
or 302 °F) -
Process pressure / max. overpressure limit
0.7 bar…1.5 bar abs
(10 psi…22 psi) -
Main wetted parts
UP (unsaturated polyester)
Silicon / Al PTFE coated -
Process connection
G / NPT 1″
-
Blocking distance
0.7 m / 80 °C,
(2.3 ft / 176 °F),
0.9 m / 150 °C,
(2.9 ft / 302 °F) -
Max. measurement distance
45 m (148 ft)
-
Communication
Transmitter:
4…20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20 mA output
-
Components
Transmitter:
FMU90, FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART , Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 80 °C
or 150 °C
(-40 °F … 176 °F
or 302 °F) -
Process temperature
-40 °C … 80 °C
or 150 °C
(-40 °F … 176 °F
or 302 °F) -
Process pressure / max. overpressure limit
0.7 bar…1.5 bar abs
(10 psi…22 psi) -
Main wetted parts
UP (unsaturated polyester)
Silicon / PE foam (80°C / 176°F)
Silicon / stainless steal (150°C / 302°F)) -
Process connection
G / NPT 1″
-
Blocking distance
0.7 m / 80 °C
(2.3 ft / 176 °F)
0.9 m / 150 °C
(2.9 ft / 302 °F) -
Max. measurement distance
45 m (148 ft)
-
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Components
Transmitter:
FMU90
Field of application
The FDU95 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in solids 45m (148ft).
Sensor for continuous, non-contact level measurement of bulk materials in silos, on belts, stockpiles and in crushers. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +80°C or +150°C (-40 to +176°F or +302°F)
Pressure: +0.7 to +1.5bar (+10 to +22psi)
Maximum measuring range: Solids 45m (148ft)
Blocking distance: 0.7m / 80°C (2.3ft), 0.9m / 150°C (2.9ft)
International explosion protection certificates
Benefits
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are presentSuited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)Reduced build-up formation because of the self-cleaning effectIntegrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioningWeather resistant and flood-proof (IP 68)Non-contact measurement method minimizes service requirementsInternational Dust-Ex and Gas-Ex certificates available
Ultrasonic measurement Time-of-Flight Prosonic FDU93
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 25m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2 mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process pressure / max. overpressure limit
0.7 bar … 3 bar abs
(10 psi … 43 psi) -
Main wetted parts
UP (unsaturated polyester)
Silicon / Al PTFE coated -
Process connection
G / NPT 1″
-
Blocking distance
0.6 m (2 ft)
-
Max. measurement distance
Liquids: 25 m (85 ft),
Solids: 15 m (50 ft) -
Communication
Transmitter:
4…20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20 mA output
-
Components
Transmitter:
FMU90, FMU95 -
Application limits
For tank farms scanner:
FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART , Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process pressure / max. overpressure limit
0.7 bar … 3 bar abs
(10 psi … 43 psi) -
Main wetted parts
UP (unsaturated polyester)
Silicon / Al PTFE coated -
Process connection
G / NPT 1″
-
Blocking distance
0.6 m (2 ft)
-
Max. measurement distance
Liquids: 25 m (85 ft),
Solids: 15 m (50 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Components
Transmitter:
FMU90
Field of application
The FDU93 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximu
Ultrasonic measurement Time-of-Flight Prosonic FDU92
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 20m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (fully welded IP68 / NEMA 6P)
-
Process connection
G / NPT 1″
-
Blocking distance
0.4 m (1.3 ft)
-
Max. measurement distance
Liquids: 20 m (65 ft),
Solids: 10 m (33 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20 mA output
-
Components
Transmitter:
FMU90, FMU95 -
Application limits
For tank farms scanner:
FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART , Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process temperature
-40 °C … 95 °C
(-40 °F … 203 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (fully welded IP68 / NEMA 6P)
-
Process connection
G / NPT 1″
-
Blocking distance
0.4 m (1.3 ft)
-
Max. measurement distance
Liquids: 20 m (65 ft),
Solids: 10 m (33 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Components
Transmitter:
FMU90
-
Measuring principle
Ultrasonic
-
Product headline
Version with separate transmitter in field housing or top hat rail housing
Cost effective solution for open channel flow measurement in water / wastewater plants -
Max. measurement error
accuracy:
distance measurement: +/- 2mm + 0.17%
Ultrasonic measurement Time-of-Flight Prosonic FDU91F
Hygienic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2 mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 105 °C
(-40 °F … 221 °F) -
Process temperature
-40 °C … 105 °C
(-40 °F … 221 °F)
CIP: 30 min: 135 °C
(30 min: 275 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
316L (fully welded IP68 / NEMA 6P)
-
Process connection
G / NPT 1″, DN80 / 100, ASME 3″ / 4″
-
Process connection hygienic
Tri-Clamp ISO2852, DN80 3 1/2″, DN100 4″
-
Blocking distance
0.3 m (1 ft)
-
Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Design approvals
EN 10204-3.1
-
Hygienic approvals
3A
-
Components
Transmitter:
FMU90, FMU95 -
Application limits
Foam / high turbulence possible:
FDU92
For tank farms scanner:
FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 105 °C
(-40 °F … 221 °F) -
Process temperature
-40 °C … 105 °C
(-40 °F … 221 °F)
30 min: 135 °C / 275 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
316L (fully welded IP68 / NEMA 6P)
-
Process connection
G / NPT 1″, DN80 / 100, ASME 3″ / 4″
-
Process connection hygienic
Tri-Clamp ISO2852, DN80 (3 1/2″), DN100 (4″)
-
Blocking distance
0.3 m (1 ft)
-
Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certifica
Ultrasonic measurement Time-of-Flight Prosonic FDU91
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 10m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2 mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (fully welded IP68 / NEMA6P)
-
Process connection
G / NPT 1″
-
Blocking distance
0.3 m (1 ft)
-
Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20 mA output
-
Components
Transmitter:
FMU90, FMU95 -
Application limits
Foam / high turbulence possible:
FDU92
Flange-flush assembly:
FDU91F
For tank farms scanner:
FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART , Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (fully welded IP68 / NEMA 6P)
-
Process connection
G / NPT 1″
-
Blocking distance
0.3 m (1 ft)
-
Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Components
Transmitter:
FMU90
Ultrasonic measurement Time-of-Flight Prosonic FDU90
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 3m)
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Specialities
Floating protection tube
-
Supply / Communication
4-wire (HART, Profibus DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (IP68 / NEMA6P)
-
Process connection
Front side thread:
G / NPT 1 1/2″
Rear side thread:
G / NPT 1″
Ceiling mounting -
Blocking distance
0.07 m (0.23 ft)
-
Max. measurement distance
Liquids: 3 m (9.8 ft),
Solids: 1.2 m (3.9 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Components
Transmitter:
FMU90, FMU95 -
Application limits
Foam / high turbulence possible:
FDU92
Flange-flush assembly:
FDU91F
For tank farms scanner:
FMU95
-
Measuring principle
Ultrasonic
-
Characteristic / Application
Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
-
Supply / Communication
4-wire (HART, PROFIBUS DP)
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Ambient temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process temperature
-40 °C … 80 °C
(-40 °F … 176 °F) -
Process pressure / max. overpressure limit
0.7 bar … 4 bar abs
(10 psi … 58 psi) -
Main wetted parts
PVDF (IP68 / NEMA6P)
-
Process connection
Front side thread:
G / NPT 1 1/2″
Rear side thread:
G / NPT 1″
Ceiling mounting -
Blocking distance
0.07 m (0.23 ft)
-
Max. measurement distance
Liquids: 3 m (9.8 ft),
Solids: 1.2 m (3.9 ft) -
Communication
Transmitter:
4 … 20 mA HART
Profibus DP -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC Ex
-
Options
Second 4…20mA output
-
Turbidity sensor Turbimax CUS52D
Hygienic Memosens sensor for turbidity measurement in drinking water, process water and utilities
-
Measuring principle
Single beam scattered light
-
Application
Turbidity measurement in:
Drinking and process water
Saline water
Utilities of all industries -
Installation
Inline Insitu, sensor with clamp, flow cell, sensor with clamp, retractables, sensor straight, immersion in open channels
-
Design
40 mm sensor
-
Dimension
40 mm design, hygienic Clamp-version
320 x 40 mm -
Material
Stainless steel version: 1.4404
Plastic version: sensor head: PEEK, shaft: PPS
Optical windows: sapphire
O-rings: EPDM -
Measurement range
0.000 to 4000 FNU
-
Ingress protection
IP68
-
Output / communication
Memosens
-
Measuring principle
Single beam scattered light
-
Application
Turbidity measurement in:
Drinking and process water
Saline water
Utilities of all industries -
Installation
Inline Insitu, sensor with clamp, flow cell, sensor with clamp, retractables, sensor straight, immersion in open channels
-
Measurement range
0.000 to 4000 FNU
Digital combined pH/ORP sensor Memosens CPS96E
Memosens 2.0 electrode for heavily polluted media in chemical processes, paper or paint production
-
Measuring principle
Potentiometric
-
Application
pH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions -
Characteristic
Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
-
Measurement range
ORP: –1 500 to 1 500 mV
pH: 0 to 14 -
Measuring principle
Pt-disc as additional ORP element
rH measurement and control of the reference impedance -
Design
All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch) -
Process temperature
0 to 110 °C (32 to 230 °F)
-
Process pressure
0.8 to 14 bar (11.6 to 203 psi) absolute
-
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 -
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
Ingress protection
IP68
-
Measuring principle
Sensor ORP / Redox
-
Application
pH / ORP sensor for heavily contaminated media
and suspended solids
• Chemical processes
• Pulp and paper industry
• Flue gas cleaning
• Contaminated media:
• Solids
• Emulsions
• Precipitation reactions -
Characteristic
Gel pH/ORP electrode with open aperture and double gel reference with ion trap for chemical applications
-
Measurement range
ORP: –1 500 to 1 500 mV
pH: 0 to 14 -
Measuring principle
Pt-disc as additional ORP element
rH measurement and control of the reference impedance -
Design
All shaft lengths with temperature sensor
Advanced gel technology
Hydrolysis stable gel -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type B
Metal lead: Ag/AgCl
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16.57 inch) -
Process temperature
0 to 110 °C (32 to 230 °F)
-
Process pressure
0.8 to 14 bar (11.6 to 203 psi) absolute
-
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 -
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
Ingress protection
IP68
Field of application
Memosens CPS96E is the specialist for media with a high content of suspended solids such as dispersions, precipitations or emulsions. The open aperture prevents fouling and ensures reliable simultaneous pH and ORP measurement. Thanks to Memosens 2.0 digital technology, CPS96E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Chemical processesPulp and paper industryContaminated media and suspended solids- Dispersions- Precipitations- EmulsionsWith ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and offering a future-proof basis for predictive maintenance and enhanced IIoT services. Simultaneous measurement of pH, ORP and rH values (in rH mode) provides a better process overview for tighter process control. Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality. Rob
Combined pH/ORP sensor Memosens CPS76E
Memosens 2.0 combined electrode for chemical processes and poisoning media
-
Measuring principle
Potentiometric
-
Application
Process technology and monitoring of processes with:
– Rapidly changing pH values
– High levels of electrode poisons, such as H2S -
Characteristic
Digital pH/ORP electrode for chemical process with an ion trap for poison-resistant reference
-
Measurement range
ORP: –1 500 to 1 500 mV
Application B
• pH: 0 to 14
Application H
• pH: 0 to 12 -
Measuring principle
Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP and rH value (in rH mode)
-
Design
All shaft lengths with temperature sensor
Advanced gel technology -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type B, Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction,
zirconium dioxide
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch) -
Process temperature
Application B and H:
0 to 140 ° C (32 to 284 ° F)
Version TB:
0 to 140 ° C (32 to 284 ° F)
Version TU, TP (pressurized reference):
0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
maximum 100 ° C (212 ° F) in continuous operation due to increasing
pressure drop at T> 100 ° C (212 ° F) -
Process pressure
Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute -
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 -
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
Ingress protection
IP68
-
Measuring principle
Sensor ORP / Redox
-
Application
Process technology and monitoring of processes with:
– Rapidly changing pH values
– High levels of electrode poisons, such as H2S -
Characteristic
Digital pH/ORP electrode for chemical process with an ion trap for poison-resistant reference
-
Measurement range
ORP: –1 500 to 1 500 mV
Application B
• pH: 0 to 14
Application H
• pH: 0 to 12 -
Measuring principle
Gel compact electrode with ceramic junction and ion trap for simultaneous measurement of pH, ORP and rH value (in rH mode)
-
Design
All shaft lengths with temperature sensor
Advanced gel technology -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type B, Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction,
zirconium dioxide
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch) -
Process temperature
Application B and H:
0 to 140 ° C (32 to 284 ° F)
Version TB:
0 to 140 ° C (32 to 284 ° F)
Version TU, TP (pressurized reference):
0 to 140 ° C (32 to 284 ° F) (140 ° C (284 ° F) for sterilization only)
maximum 100 ° C (212 ° F) in continuous operation due to increasing
pressure drop at T> 100 ° C (212 ° F) -
Process pressure
Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute -
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 -
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
Ingress protection
IP68
Field of application
Memosens CPS76E is the heavy-duty specialist for simultaneous pH and ORP measurement. Its unique, contamination-resistant reference guarantees stable measurement in polluted, poisoning media and in media with low conductivity. Thanks to Memosens 2.0 digital technology, CPS76E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Processes in chemical industry and monitoring of processes with:Quickly changing pH or ORP valuesHigh proportion of electrode poisons such as H2S With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zone
Digital pH sensor Memosens CPS71E
Memosens 2.0 pH electrode for chemical processes and poisoning media
-
Measuring principle
Potentiometric
-
Application
Process technology and monitoring of processes with:
• Rapidly changing pH values
• High proportion of electrode poisons such as H2S -
Characteristic
Digital pH electrode for chemical process with an ion trap for poison-resistant reference
-
Measurement range
Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12 -
Measuring principle
Gel compact electrode with ceramic junction and ion trap
-
Design
All shaft lengths with temperature sensor
Advanced gel technology -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type B, Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction, zirconium dioxide
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch) -
Process temperature
1 to 140 °C (32 to 284 °F)
-
Process pressure
0,8 to 14 bar (11,6 to 203 psi) (absolute)
-
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2. -
Connection
Inductive, contactless connection head with Memosens 2.0 technology
-
Ingress protection
IP68
-
Additional certifications
Additional certifications
Field of application
Memosens CPS71E is specially designed for demanding processes. Its unique, contamination-resistant reference and its resistance to moisture ensure reliable measurement even in heavily polluted, aggressive media such as strong acids and bases. Thanks to Memosens 2.0 digital technology, CPS71E offers extended storage of calibration and process data providing the perfect basis for predictive maintenance. Pre-calibration in the lab and quick sensor exchange on site maximize process uptime.
Processes in chemical industry and monitoring of processes with:High proportion of electrode poisons such as H2SQuickly changing pH values With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Benefits
The electrode’s unique ion trap prevents poisoning of the junction and reference, making it resistant to strong acids and bases and ensuring a long sensor lifetime. The optional pressurized reference allows for reliable measurement in blocking media such as dispersions.Flexible installation thanks to optional upside-down mounting Inductive cable connection and non-contact signal transmission eliminate any problems due to moisture or corrosion and increase process integrity.Fast sensor exchange on site reduces process downtime and operating costs. Memosens 2.0 digital technology makes trend identification and predictive maintenance possible thanks to its extended storage of calibration and process data. The technology paves the way for advanced IIoT services.
Digital ORP sensor Memosens CPS62E
Memosens 2.0 ORP electrode for the chemical and life sciences industries
-
Measuring principle
Sensor ORP / Redox
-
Application
Hygiene and sterile applications (sterilizable, autoclavable):
• Fermenter
• Biotechnology
• Pharma -
Characteristic
Digital ORP electrode for hygienic production processes with ion trap
for long-term stable reference -
Measurement range
–1 500 to 1 500 mV
-
Measuring principle
Gel compact electrode with ceramic junction and ion trap
Measuring element platinum cap -
Design
All shaft lengths with temperature sensor
Advanced gel technology -
Material
Sensor shaft: Glass to suit process
Metal lead: Ag/AgCl
Open aperture: Ceramic junction,
zirconium dioxide
ORP measuring element: Platinum
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225 and 360 mm
(4.68, 8.77 and 14.04 inch) -
Process temperature
0 to 100 °C (32 to 212 °F)
0 to 140 °C (32 to 284 °F) (140 °C (284 °F) or sterilization only) -
Process pressure
0.8 to 7 bar (11.6 to 101.5 psi) absolute
-
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 -
Connection
Inductive, digital connection head with Memosens 2.0 technology
-
Ingress protection
IP68
-
Additional certifications
Additional certifications
Field of application
Memosens CPS62E is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media, in low conductivities and at high temperatures. Thanks to Memosens 2.0 digital technology, CPS62E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Process technology and monitoring of processes with:- Quickly changing ORP values- High proportion of electrode poisons such as H2SChemical processesHygienic and sterile applications:- Fermenters- Biotechnology- Life sciencesWith ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Sensor resists strong acids and bases and high organic loads. Maintains high accuracy even after CIP/SIP or autoclaving. Free from animal-based materials and from acrylamide. Upside-down mounting option allows for flexible installation. Maximum process safety is ensured by non-contact, inductive signal transmission. Minimized process downtime and extended sensor lifetime result in reduced operating costs.
Digital pH sensor Memosens CPS61E
Memosens 2.0 glass sensor for the food & beverage industry and for bioreactors in biotech industry
-
Measuring principle
Potentiometric
-
Application
Hygienic and sterile applications (sterilizable, autoclavable):
• Bioreactor/fermenter
• Biotechnology
• Pharmaceutical industry
• Foods -
Characteristic
Digital pH electrodes for hygienic production processes with ion trap for
long-term stable reference -
Measurement range
pH: 0 to 14
-
Measuring principle
Gel compact electrode with ceramic junction and ion trap
-
Design
All shaft lengths with temperature sensor
Advanced gel technology -
Material
Sensor shaft: Glass to suit process
pH membrane glass: Type N
Metal lead: Ag/AgCl
Open aperture: Ceramic junction, zirconium dioxide
O-ring: FKM
Process coupling: PPS fiber-glass reinforced
Nameplate: Ceramic metal oxide -
Dimension
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch) -
Process temperature
Application N:
0 to 100 °C (32 to 212 °F)
Up to 140 °C (284 °F) for sterilization -
Process pressure
0.8 to 7 bar (11.6 to 101.5 psi) absolute
-
Temperature sensor
NTC 30k
-
Ex certification
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2. -
Connection
Inductive, contactless connection head with Memosens 2.0 technology
-
Ingress protection
IP68
Field of application
Keep the pH value in the optimum range and maximize your product yield with Memosens CPS61E. Its rugged design and long-term stability ensure extremely accurate and reproducible measured values even after CIP/SIP or autoclaving. CPS61E features Memosens 2.0 digital technology, offering extended storage of calibration and process data for predictive maintenance. The sensor resists moisture and enables lab calibration, enhancing process integrity and increasing process uptime.
Memosens CPS61E measures pH in:
Biotech and pharma industries – Bioreactors/fermenters: process control in enzyme production- Bioreactors/fermenters: control of culture growth
Food & Beverage- CIP/SIP applications
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
A pharma certificate of compliance with sensor serial number specified is available.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. The sensor’s exceptional accuracy and reproducibility help you to keep the pH value in the optimum range for a maximized product yield. A special glass membrane and reference system makes the sensor CIP/SIP and autoclaving resistant (up to 140°C/284°F) offering maximum long-term stability.The sensor protects your product quality with its certified biocompatibility according to USP class VI, FDA compliance of wetted parts, VO 1935/2004 compliance, no cytotoxicity, bioreactivity or animal-based materials. Streamline maintenance of CPS61E with the Memobase Plus software that automatically stores and documents all relevant sensor and process data. Maximum process safety through non-contact, inductive signal transmission Reduced operating costs thanks to minimized process downtime and extended sensor lifetime.
Digital pH sensor Memosens CPS171D
Memosens glass electrode for bioreactors in the biotech industry and for the food industry
-
Measuring principle
Potentiometric
-
Application
Hygienic and sterile applications, bioreactor, fermenter, biotechnology, pharmaceutical industry, foods
-
Characteristic
Digital pH electrodes for bioreactors and biotechnology production processes with ion
trap for long-term stable reference -
Measurement range
pH 0 to 14
-
Measuring principle
Ceramic diaphragm, ion-trap
-
Design
All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology -
Material
Glass and ceramic
-
Dimension
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.72, 8.86, 14.2 and 16.7 inch) -
Process temperature
0 to 135 °C (32 to 275 °F)
-
Process pressure
1 to 7 bar abs (14.5 to 101.5 psi)
-
Temperature sensor
NTC 30k
-
Ex certification
IECEx, ATEX, NEPSI, FM, CSA
-
Connection
Inductive, digital connection head with Memosens technology
Field of application
Keep the pH value of your batch in the optimum range and maximize your product yield with Memosens CPS171D. Thanks to its rugged design and long-term stability, it provides extremely accurate, reproducible and reliable measuring values even after CIP/SIP and autoclaving. Memosens CPS171D is not the latest Memosens generation. To get information on the new Memosens CPS61E sensor with extended functionality, click here.
Digital ORP sensor Memosens CPF82E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
-
Measuring principle
Sensor ORP / Redox
-
Application
Flotation, leaching, neutralization, outlet monitoring
-
Characteristic
Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4″
-
Measurement range
-1500mV to +1500mV
-
Measuring principle
Gel-compact electrode with double chamber reference system, potassium nitrate bridge electrolyte and PTFE-diaphragm, platinum ring
-
Design
Compact electrode in PPS housing with NPT3/4″ process connection
-
Material
Housing: PPS
ORP electrode: platinum ring
Double chamber reference system: KNO3 and KCl/AgCl -
Dimension
Diameter: 22 mm (0.87 inch)
Length: 150 mm (5.91 inch) -
Process temperature
0 to 80 °C (32 to 170 °F)
-
Process pressure
1 to 10 bar abs at 80 °C
(15 to 145 psi abs at 176 °F) -
Temperature sensor
NTC
-
Ex certification
(optional) FM IS NI Cl. I Div.1&2, Groups A-D
-
Connection
Process connection: NPT 3/4″
Memosens plug -
Ingress protection
IP 68
Field of application
Memosens CPF82E is the digital, robust solution for ORP measurement in harsh environments. Its large, dirt-repellent PTFE junction guarantees low maintenance while its integrated assembly offers easy and compact installation. Thanks to Memosens 2.0 digital technology, CPF82E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Memosens CPF82E is the robust ORP sensor for treatment of industrial water and wastewater and for processes in mining industries. It monitors:Inlet and outletNeutralizationFlotationLeachingWith CSA C/US approval for use in hazardous areas, zones 0, 1 and 2.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Long time stable: Double junction provides better protection against electrode poisoning ions such as S2- or CN-. Robust polymer housing protects against mechanical damage. The sensor is suitable for flow and immersion installation Non-contact, inductive signal transmission maximizes process safety.Minimum process downtime and extended sensor lifetime reduce operating costs.
Digital pH sensor Memosens CPF81E
Memosens 2.0 compact electrode for wastewater, mining, minerals and metal industries
-
Measuring principle
Potentiometric
-
Application
Flotation, leaching, neutralization, outlet monitoring
-
Characteristic
Resistent against electrolyte poisoning and dirt repellent gel-electrode including process connection NPT 3/4″
-
Measurement range
pH 0 to 14
-
Measuring principle
Gel-compact electrode with double chamber reference system, kalium nitrate bridge electrolyte and PTFE-diaphragm
-
Design
Compact electrode in PPS housing with NPT 3/4″ process connection
-
Material
Housing: PPS
pH electrode: lead-free membrane glass
Double chamber reference system: KNO3 and KCl/AgCl -
Dimension
Diameter: 22 mm (0.87 inch)
Length (protcetion guard, long shaft): 150 mm (5.91 inch)
Length (flat membrane): 140 mm (5.51 inch) -
Process temperature
Version LH: 0 to 110 °C (32 to 230 °F)
Version NN: 0 to 80 °C (32 to 170 °F) -
Process pressure
1 to 10 bar abs at 80 °C
(15 to 145 psi at 176 °F) -
Temperature sensor
NTC 30K
-
Ex certification
(optional) FM IS NI Cl. I Div.1&2, Groups A-D
-
Connection
Memosens plug
-
Ingress protection
IP68
Field of application
Memosens CPF81E is the digital, robust solution for harsh environments. It measures reliably and accurately even in abrasive media and at high flow rates. With its integrated assembly, the electrode saves installation space. Thanks to Memosens 2.0 digital technology, CPF81E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Memosens CPF81E is the robust pH sensor for processes in mining industries and treatment of industrial water and wastewater. It monitors:FlotationLeachingNeutralizationInlet and outlet With CSA C/US approval for use in hazardous areas, zones 0, 1 and 2.
Benefits
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services. Long time stable: Double junction provides better protection against electrode poisoning ions such as S2- or CN-. Robust polymer housing protects against mechanical damage. Optional flat membrane makes the sensor suitable for high flow rates and abrasive media. Non-contact, inductive signal transmission ensures maximum process safety. Maximum process uptime and extended sensor lifetime reduce operating costs.
Process spectrometer Memosens Wave CKI50
Memosens Wave spectrometer for color measurement in the Food & Beverage, Chemical and Life Sciences industries
-
Measuring principle
Absorption
-
Application
Color measurement CIE Lab
-
Measurement range
L: 0 to 100
a: -150 to 100
b: -100 to 150 -
Material
Measuring head: 1.4404/AISI316L
Window: Sapphire
O-rings: FFKM
Gasket seal: PEEK -
Process temperature
-20 to 60 °C (-4 to 140 °F)
60 to 140 °C (140 to 284 °F) with water cooling -
Process pressure
0.5 to 10 bar (7.3 to 145 psi) (absolute)
-
Ex certification
ATEX/IECEx II 1/2G Ex ia op is/db [ia Ga] IIC T6…T3 Ga/Gb
-
Ingress protection
IP 69 (NEMA 6P)
Field of application
Memosens Wave CKI50 impresses with its compact design, which allows the spectrometer to provide reliable and fast color control directly in the process. At the same time, the process spectrometer ensures hygiene and material standards in accordance with the specifications of the food industry. Thanks to a preset color model and the connection to a Liquiline transmitter, commissioning is very easy and you benefit from stable measurements.
Quality control: Color deviations in end products are caused by color variations in the raw materials. Therefore, recognizing them and initiating appropriate adjustments is crucial Filling control: Increasing product diversity and rising production speed pose a risk of incorrect bottling. Reliable and fast color detection is crucial.Phase control: With color detection, phases in pipes can be recognized quickly and product losses can be minimized, e.g. when changing products or during cleaning.
Benefits
Compact design: Determination of color across the entire color spectrum with just a single device.Easy commissioning: Thanks to Memosens technology and the Liquiline transmitter, installation is quick and easy. No calibration required, only a reference spectrum of the zero point has to be recorded.Robust color measurement: Highly repeatable and long-term reliable color measurements even in demanding process environments, thanks to a high resistance to water ingress and vibration as well as higher temperatures.Safe and efficient process control: The hygienic design ensures products are made safely. By checking the color directly in the process, product loss and potential health risks to consumers can be prevented
PAH sensor Memosens CFS51
Memosens sensor for measuring the concentration of polycyclic aromatic hydrocarbons in discharge water of marine exhaust gas cleaning systems (EGCS)
-
Measuring principle
Fluorescence measurement
-
Application
PAH measurement in marine exhaust gas cleaning systems
-
Measurement range
0.000 to 5000 PAHphe
-
Design
40 mm sensor
-
Material
Titanium grade 3.7035
Optical windows: sapphire
O-rings: FKM -
Process temperature
-5 to 55 °C (20 to 130 °F)
-
Process pressure
10 bar abs. (just the sensor)
6 bar abs. (combination sensor and assembly) -
Ingress protection
IP68
NEMA 6P -
Additional certifications
Marine type approvals by DNV, LR, BV, ABS
Statement of compliance according to MEPC.259(68) and MEPC.340(77) by DNV
Field of application
The rugged and low-maintenance Memosens CFS51 fluorescence sensor measures polycyclic aromatic hydrocarbons (PAHs) in accordance with MEPC.259(68) and MEPC.340(77). Thanks to the practical solid-state reference, you can readjust and calibrate the sensor onboard the vessel – supported by user-friendly guidance in the transmitter menu. This makes the calibration procedure simple and error-free, and you benefit from an exceptionally long factory maintenance interval of 4 years.
Memosens CFS51 measures PAHs with high accuracy in both the inlet and outlet of marine exhaust gas cleaning systems (scrubbers) and is suitable for all discharge water flow rates.The sensor is certified by the following approval bodies: DNV (Det Norske Veritas)LR (Lloyd’s Register)BV (Bureau Veritas)ABS (American Bureau of Shipping) For washwater monitoring in EGCS, the PAH sensor is also available as an approved all-in-one solution including pH and turbidity measurement.
Benefits
The uniquely long factory maintenance interval saves you a lot of costs and organizational effortThe optionally available flow assembly holds the sensor at the ideal installation angle to minimize disturbing influences caused by air bubbles. In addition, it can be tilted for quick mounting and dismounting of the sensor.DNV approved integrated turbidity correction in the range of 0-50 FNUHigh material compliance of sensor and flow assembly according to IACS E10 (flame retardancy)The solid-state reference makes calibration very easy for the end user – and you can completely eliminate the need for toxic phenantrene, which increases safety for your employees and the environmentThe suitability of the solid-state reference for calibration and readjustment of the PAH sensor on board was confirmed by DNV
Cleaning and calibration system Liquiline Control CDC90
Fully automatic system for pH and ORP measuring points in all industries
-
Measuring principle
Potentiometric
-
Application
Automates Memosens pH and ORP measuring points in all industries
-
Installation
Complete automated cleaning and validation system including a selectable retractable holder
-
Characteristic
Full automatic cleaning, monitoring and validation system for Memosens sensor
-
Design
Compact cleaning system to connect on a retractable holder including transmitter
-
Dimension
237 x 194 x 162 mm (l x h x w)
9.33 x 7.64 x 6.38 inch (l x h x w) -
Connection
DCS/PLS connection on Modbus TCP, Ethernet IP, Profinet, ProfibusDP and current in/ output
-
Additional certifications
CE, CSA general purpose
Field of application
The Liquiline Control CDC90 plug & play system automates Memosens pH and ORP measuring points in all industries. It cleans, validates, calibrates and adjusts up to two sensors automatically, reducing maintenance effort, improving working safety in harmful areas and helping to ensure the yield and quality of your product. It can easily be integrated into existing plant infrastructures and allows convenient remote control of your measuring points via any process control system or mobile device.
Liquiline Control CDC90 automates pH and ORP measuring points in all industries. It is suitable for each application where:
The sensors must be cleaned and/or calibrated frequently.
The measuring point is difficult to access.
The measuring point is in a harmful environment.
The process requires reproducible precise pH measurement.
The process requires measurement at frequent intervals.
The performance of the measuring point must be controlled and documented frequently.
Benefits
Optimized cleaning and calibration cycles ensure reliable and reproducible measured values that help you to improve product yield, product quality and raw material consumption. Pro-active cleaning and calibration in case of sensor blocking and fouling ensures reliable values to keep your product safe. Increased safety for your service personnel as it minimizes maintenance actions in difficult-to-access areas and harsh or harmful environments. Seamless system integration into your process control system thanks to certified communication standards such as 0/4…20mA, PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET and web server technology.Pre-defined cleaning and calibration programs allow a quick start and commissioning of Liquiline Control CDC90 and keep your investment effort low.
Digital free chlorine sensor Memosens CCS51D
Memosens sensor for drinking water, pool and process water as well as utilities in all industries
-
Measuring principle
Free chlorine
-
Application
Ensuring reliable disinfection in drinking water
Process water
Dosing disinfectant efficiently in pool water
Detect the absence or presence of free chlorine in Utilities
Guarantee food safety and provide hygienic packaging and bottling -
Characteristic
Amperometric measurement of dissolved free chlorine
-
Measurement range
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl -
Measuring method
Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode -
Design
Closed amperometric 2-electrode measuring cell with PVDF membrane
-
Material
Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF
Sealing ring: FKM -
Dimension
Diameter: 25 mm (0.98 inch)
Length: 161 mm (6.34 inch) -
Process temperature
0 to 55 °C (32 to 130 °F), non-freezing
-
Process pressure
Max. 1 bar (max. 14.5 psi)
-
Temperature sensor
10k NTC integrated (Memosens)
-
Connection
Inductive, digital connection head with Memosens
Field of application
Memosens CCS51D is a robust, low-maintenance sensor for free chlorine. It provides high-precision measurement with long-term stability in drinking water, pool and process water and ensures consistent disinfection monitoring even at low water volumes. The free chlorine sensor features extremely fast response times guaranteeing efficient process control. Memosens CCS51D is not the latest Memosens generation. More information on the new Memosens CCS51E sensor with extended functionality here.
Memosens CCS51D is a free chlorine sensor for skid builders and end customers. It measures reliably in:Drinking water – to ensure reliable disinfectionProcess water – for hygienic and safe packaging and bottling of productsUtilities – to detect the absence or presence of free chlorinePool water – to dose disinfectant efficiently
Benefits
The right sensor version for every application: From trace measurement up to free chlorine concentrations of 200 mg/l. Fast response time (t90 < 25 s) provides an accurate process view and enables prompt reaction to process changes as well as efficient process control.Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for individually adapted disinfectant dosing. The low-maintenance, amperometric sensor reduces the cost of ownership of the measuring point, particularly compared to colorimetric measuring systems. More process up-time thanks to fast sensor exchange: pre-calibrate the sensor in your lab and then swap it into your process with plug & play.Connection to the Liquiline multiparameter transmitter allows for easy combination with other relevant parameters of liquid analysis such as pH and ORP.
Digital chlorine dioxide sensor Memosens CCS50D
Memosens sensor for water, process water and utilities in all industries
-
Measuring principle
Chlorine dioxide
-
Application
Adequate disinfection in drinking water, preventing of pathogen formation in cooling water systems, water used to wash pre-packaged vegetables, ensures the absence of chlorine dioxide in beverage systems
-
Characteristic
Amperometric measurement of dissolved chlorine dioxide
-
Measurement range
Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2 -
Measuring principle
Closed, membrane covered measuring cell
Reduction of chlordioxide (ClO2) to chloride at the cathode with appr. 120mV -
Design
Closed amperometric 2-electrode measuring cell with PVDF membrane
-
Material
Sensor shaft: POM
Membrane: PVDF
Membrane cap: PVDF -
Dimension
Diameter: 25 mm (0.98 inch)
Length: 161 mm (6.34 inch) -
Process temperature
0 to 55 °C , non-freezing
(32 to 130 °F) -
Process pressure
Max. 2 bar abs
(Max. 29 psi abs) -
Temperature sensor
10k NTC integrated (Memosens)
-
Connection
Inductive, digital connection head with Memosens
Field of application
Memosens CCS50D is a robust, low maintenance sensor for chlorine dioxide measurement. It provides stable and fast measured values in drinking water, process water and utilities. The sensor can be used to ensure efficient disinfection for highest water quality and safety, to avoid overdosing of chlorine dioxide or to ensure the absence of ClO2 in beverage plants and reverse osmosis. Memosens CCS50D is not the latest Memosens generation. More information on the new Memosens CCS50E sensor here.
Memosens CCS50D is a chlorine dioxide sensor for skid builders and end customers. It measures reliably in:Drinking water to ensure sufficient disinfectionCooling systems or towers to avoid pathogen growthProcess water – for hygienic and safe packaging and bottling of productsBeverage plants to secure the absence of chlorine dioxide
Benefits
The right sensor version for every application: From trace measurement up to chlorine dioxide concentrations of 200 mg/l.Fast response time provides accurate process view and enables prompt reaction to process changes as well as efficient process control. Increased process safety: precise and long-term stable measurement ensures consistent process monitoring and allows for lowest disinfectant concentration. Flexible installation: sensor can be installed in the CCA151 and CCA250 flow assemblies or in immersion assemblies. Measurement virtually flow independent at flow velocities above 5 l/h (CCA151), 30 l/h (CCA250) or above 15 cm/s (immersion).More process up-time thanks to fast sensor exchange: precalibrate the sensor in your lab and then swap it into your process with plug & play. Connection to the Liquiline multiparameter transmitter allows easy combination with other relevant parameters of liquid analysis.
Orthophosphate analyzer Liquiline System CA80PH
Colorimetric system for wastewater monitoring and optimization of process control
-
Measuring principle
Colorimetric
-
Characteristic
Process analyzer for orthophosphate in aqueous solutions
Comply with standard colorimetric measuring principle, molybdenum blue method, following DIN EN 1189 or molybdate vanadate method -
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
At atmospheric pressure, < 0.2 bar
-
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
-
Consistency of the sample
Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized -
Application
Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
24 VDC ± 10%
50 ± 1 or 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP -
Input
1 or 2 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0 to 2.5 mg/l PO4-P (blue method)
0.05 to 10 mg/l PO4-P (blue method)
0.05 to 10 mg/l with dilution function to maximum 2.5 to 500 mg/l PO4-P (blue method)
0.5 to 20 mg/l PO4-P (yellow method)
0.5 to 50 mg/l PO4-P (yellow method)
0.5 to 50 mg/l with dilution function to maximum 10 to 1000 mg/l PO4-P (yellow method) -
Consumables
Reagents and standard solutions CY80H as well as cleaner CY800 (blue method) are necessary for the operation
Regular maintenance is done with the parts of the maintenance kit CAV800
Field of application
Liquiline System CA80PH offers online orthophosphate measurement for precise dosing of precipitants in wastewater treatment. As all Liquiline System analyzers, it enables plug & play of up to 4 Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low consumption of reagents save you operating costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.
Liquiline System CA80PH supports you in optimizing the cleaning capacity of wastewater treatment plants. It monitors and controls:
Precipitant dosing in aeration basins
Wastewater treatment plant outlets
In industrial applications, Liquiline System CA80PH is used for the monitoring of cooling water cycles.
Benefits
Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation
Easy upgrade of functionality – even to a complete measuring station – simply by adding modules and connecting Memosens sensors Advanced diagnostics with remote access for increased process safety Reduced operating costs through automatic calibration and cleaning and long reagent shelf life with cooling moduleAvailable with both standardized measuring methods covering all applications: Molybdenum blue method and Molybdate Vanadate yellow method
COD analyzer Liquiline System CA80COD
Analyzer for chemical oxygen demand in environmental monitoring, industrial and municipal wastewater
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for chemical oxygen demand (COD)
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: – 20 to 40 °C (-4 to 104 °F) -
Process pressure
Atmospheric
-
Sample flow rate
min. 30 ml/min
-
Consistency of the sample
Aqueous homogeneous sample
-
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Self-priming analyzer with optical dosing unit l
Dilution module (optional)
Digital communication for remote access -
Application
Environmental monitoring, limit value monitoring of industrial and municipal waste water
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
50 ± 1 oder 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Webserver (optional)
EtherNet/IP
PROFIBUS DP
Alarmrelay -
Input
1 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measurement range
0 to 500 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method + dilution module (1:4) -
Consumables
Reagents and standard solutions CY80COD are necessary for the operation
Field of application
Liquiline System CA80COD offers constant online measurement of the chemical oxygen demand (COD). It supports you in monitoring the cleaning capacity of wastewater treatment plants and enables load-based billing for industrial dischargers. Automatic calibration and cleaning save operating costs while advanced diagnostics with remote access help to provide process documentation to authorities. The COD analyzer’s software-controlled safety functions ensure the highest level of occupational safety.
The Liquiline System COD analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water
Benefits
Established COD dichromate method directly comparable to laboratory results. Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater. Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications.Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts. Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing.Easy upgrade of functionality to a complete measuring station – simply by adding modules and connecting Memosens sensors.